Jour faible : charge maximale en HC de midi (bilan vise 100 %, plafond ACM = abonnement - maison + solaire)
This commit is contained in:
@@ -71,18 +71,38 @@ export const scenarios = [
|
||||
time: h(ETE, '12:30'),
|
||||
overrides: { ...parcNeuf, soc_percent: '31', night_takeover: 'on', edf_switch: 'on',
|
||||
night_target_soc: '44.1', grid_energy_needed_kwh: '3.91', house_ac_power_w: '5300',
|
||||
grid_subscription_va: '12000', battery_voltage_v: '51' },
|
||||
grid_subscription_va: '12000', battery_voltage_v: '51', pv_power_w: '1550' },
|
||||
expect: { mode: 'evcs_takeover_recover', courantA: 50 },
|
||||
},
|
||||
{
|
||||
id: 'acm-takeover-midi-borne-par-l-abonnement',
|
||||
label: 'Meme midi, maison a 9,5 kW : il ne reste que 1,3 kW sous les 90 % des 12 kVA -> 25,5 A',
|
||||
label: 'Meme midi, maison a 9,5 kW, pas de solaire : il ne reste que 1,3 kW sous les 90 % des 12 kVA -> 25,5 A',
|
||||
time: h(ETE, '12:30'),
|
||||
overrides: { ...parcNeuf, soc_percent: '31', night_takeover: 'on', edf_switch: 'on',
|
||||
night_target_soc: '44.1', grid_energy_needed_kwh: '3.91', house_ac_power_w: '9500',
|
||||
grid_subscription_va: '12000', battery_voltage_v: '51' },
|
||||
grid_subscription_va: '12000', battery_voltage_v: '51', pv_power_w: '0' },
|
||||
expect: { mode: 'evcs_takeover_recover', courantA: 25.5 },
|
||||
},
|
||||
// CHARGE MAXIMALE (08/10/2026) : jour faible, le bilan vise 100 % a midi ; le
|
||||
// courant n'est plus fixe par la cible mais par la physique.
|
||||
{
|
||||
id: 'acm-takeover-midi-jour-faible-charge-max-solaire-compte',
|
||||
label: 'Jour faible 12:30, SOC 31 -> 100 % (20,7 kWh), maison 5,8 kW, PV 1,55 kW : (10 800 - 5 800 + 1 550) / 51 = 128,4 A',
|
||||
time: h(ETE, '12:30'),
|
||||
overrides: { ...parcNeuf, soc_percent: '31', night_takeover: 'on', edf_switch: 'on',
|
||||
night_target_soc: '100', grid_energy_needed_kwh: '20.7', house_ac_power_w: '5800',
|
||||
grid_subscription_va: '12000', battery_voltage_v: '51', pv_power_w: '1550' },
|
||||
expect: { mode: 'evcs_takeover_recover', courantA: 128.4 },
|
||||
},
|
||||
{
|
||||
id: 'acm-takeover-midi-jour-faible-charge-max-chargeurs',
|
||||
label: 'Meme midi, maison 2 kW : 202 A possibles, borne aux 140 A des deux MultiPlus',
|
||||
time: h(ETE, '12:30'),
|
||||
overrides: { ...parcNeuf, soc_percent: '31', night_takeover: 'on', edf_switch: 'on',
|
||||
night_target_soc: '100', grid_energy_needed_kwh: '20.7', house_ac_power_w: '2000',
|
||||
grid_subscription_va: '12000', battery_voltage_v: '51', pv_power_w: '1500' },
|
||||
expect: { mode: 'evcs_takeover_recover', courantA: 140 },
|
||||
},
|
||||
{
|
||||
id: 'acm-takeover-nuit-petit-besoin-plancher-10a',
|
||||
label: 'Nuit 01:30, 1 kWh a reprendre en 5,9 h : 3,8 A calcules -> plancher 10 A (la batterie est menagee)',
|
||||
|
||||
Reference in New Issue
Block a user