diff --git a/src/nodes/HA_SNAPSHOT_TEMPLATE.json.tpl b/src/nodes/HA_SNAPSHOT_TEMPLATE.json.tpl index fb7b031..12358be 100644 --- a/src/nodes/HA_SNAPSHOT_TEMPLATE.json.tpl +++ b/src/nodes/HA_SNAPSHOT_TEMPLATE.json.tpl @@ -63,6 +63,9 @@ "battery_neutral_band_a": states("input_number.victron_evcs_battery_neutral_band_a"), "soc_start_min": states("input_number.victron_evcs_soc_start_min"), "modules_en_service": states("input_number.evcs_balance_modules_en_service"), + + "bms_max_discharge_current_a": states("sensor.airtria_8_us2000c_maximum_allowed_discharge_current"), + "bms_max_charge_current_a": states("sensor.airtria_8_us2000c_maximum_allowed_charge_current"), "soc_stop_min": states("input_number.victron_evcs_soc_stop_min"), "current_min_a": states("input_number.victron_evcs_current_min_a"), "current_max_auto_a": states("input_number.victron_evcs_current_max_auto_a"), diff --git a/src/nodes/INPUT_PARSE.js b/src/nodes/INPUT_PARSE.js index 2c7df3d..0313430 100644 --- a/src/nodes/INPUT_PARSE.js +++ b/src/nodes/INPUT_PARSE.js @@ -664,6 +664,44 @@ const history = { evcsNoDemandFilterEvalMs: parseParisStampToMs(evcsNoDemandFilterEvalAtRaw), }; +// ===================================================== +// MISE A L'ECHELLE DU PARC (12/09/2026) +// ===================================================== +// Les bandes ci-dessous sont en AMPERES ABSOLUS, et elles decrivent un parc +// de 4 modules -- celui sur lequel elles sont aujourd'hui en vigueur et +// observees justes (l'arret dur du 11/09 a mordu au bon endroit, 87 A pour +// une limite de 70). Avec quatre US5000 en plus, le parc triple : garder ces +// ampere-la briderait le nouveau parc au niveau de l'ancien. +// +// On les met donc a l'echelle du parc DECLARE — le meme helper que la +// capacite utile et que le bilan energetique, exprime en equivalents +// US2000C (un US5000 en vaut DEUX). Une seule valeur a tenir a jour, et les +// trois consommateurs restent forcement d'accord entre eux. +// +// ⚠️ On ne met PAS a l'echelle sur la limite BMS lue en direct : elle +// s'effondre quand une cellule monte en tension (04/09 : plafond de charge +// tombe de 150 a 20 A en cinq secondes). Une regle de confort ne doit pas +// suivre un signal aussi nerveux. En revanche le BMS PLAFONNE : on ne +// s'autorise jamais plus que ce que le parc declare accepter a l'instant. +// +// Parc absent ou illisible => echelle 1 et plafond inactif, donc comportement +// d'aujourd'hui strictement inchange. +const parkScale = (() => { + const n = Number(input.modules_en_service); + return Number.isFinite(n) && n >= 1 && n <= 32 ? n / 4 : 1; +})(); +const bmsDischargeCapA = (() => { + const n = Number(input.bms_max_discharge_current_a); + return Number.isFinite(n) && n > 0 ? n : Infinity; +})(); +const bmsChargeCapA = (() => { + const n = Number(input.bms_max_charge_current_a); + return Number.isFinite(n) && n > 0 ? n : Infinity; +})(); +// Decharge : valeurs NEGATIVES, donc le plafond est un `Math.max`. +const scaleDischargeA = v => Math.max(-bmsDischargeCapA, v * parkScale); +const scaleChargeA = v => Math.min(bmsChargeCapA, Math.max(0, v) * parkScale); + // ===================================================== // BATTERY TUNING // ===================================================== @@ -681,54 +719,54 @@ const batteryTune = { bands: { gt90: { - dischargeSoftA: num(input.batt_discharge_soft_gt90_a, -50), - dischargeHardA: num(input.batt_discharge_hard_gt90_a, -100), - chargeReserveA: Math.max(0, num(input.batt_charge_reserve_gt90_a, 5)), + dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_gt90_a, -50)), + dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_gt90_a, -100)), + chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_gt90_a, 5)), softToleranceMin: Math.max(0, num(input.batt_soft_tol_gt90_min, 12)), hardToleranceSec: Math.max(0, num(input.batt_hard_tol_gt90_sec, 20)), recoveryMin: Math.max(0, num(input.batt_recovery_gt90_min, 6)), }, '80_90': { - dischargeSoftA: num(input.batt_discharge_soft_80_90_a, -40), - dischargeHardA: num(input.batt_discharge_hard_80_90_a, -80), - chargeReserveA: Math.max(0, num(input.batt_charge_reserve_80_90_a, 10)), + dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_80_90_a, -40)), + dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_80_90_a, -80)), + chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_80_90_a, 10)), softToleranceMin: Math.max(0, num(input.batt_soft_tol_80_90_min, 10)), hardToleranceSec: Math.max(0, num(input.batt_hard_tol_80_90_sec, 20)), recoveryMin: Math.max(0, num(input.batt_recovery_80_90_min, 6)), }, '60_80': { - dischargeSoftA: num(input.batt_discharge_soft_60_80_a, -20), - dischargeHardA: num(input.batt_discharge_hard_60_80_a, -50), - chargeReserveA: Math.max(0, num(input.batt_charge_reserve_60_80_a, 40)), + dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_60_80_a, -20)), + dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_60_80_a, -50)), + chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_60_80_a, 40)), softToleranceMin: Math.max(0, num(input.batt_soft_tol_60_80_min, 6)), hardToleranceSec: Math.max(0, num(input.batt_hard_tol_60_80_sec, 15)), recoveryMin: Math.max(0, num(input.batt_recovery_60_80_min, 8)), }, '40_60': { - dischargeSoftA: num(input.batt_discharge_soft_40_60_a, -12), - dischargeHardA: num(input.batt_discharge_hard_40_60_a, -30), - chargeReserveA: Math.max(0, num(input.batt_charge_reserve_40_60_a, 70)), + dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_40_60_a, -12)), + dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_40_60_a, -30)), + chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_40_60_a, 70)), softToleranceMin: Math.max(0, num(input.batt_soft_tol_40_60_min, 4)), hardToleranceSec: Math.max(0, num(input.batt_hard_tol_40_60_sec, 10)), recoveryMin: Math.max(0, num(input.batt_recovery_40_60_min, 10)), }, '25_40': { - dischargeSoftA: num(input.batt_discharge_soft_25_40_a, -5), - dischargeHardA: num(input.batt_discharge_hard_25_40_a, -15), - chargeReserveA: Math.max(0, num(input.batt_charge_reserve_25_40_a, 110)), + dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_25_40_a, -5)), + dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_25_40_a, -15)), + chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_25_40_a, 110)), softToleranceMin: Math.max(0, num(input.batt_soft_tol_25_40_min, 2)), hardToleranceSec: Math.max(0, num(input.batt_hard_tol_25_40_sec, 5)), recoveryMin: Math.max(0, num(input.batt_recovery_25_40_min, 12)), }, lt25: { - dischargeSoftA: num(input.batt_discharge_soft_lt25_a, -3), - dischargeHardA: num(input.batt_discharge_hard_lt25_a, -8), - chargeReserveA: Math.max(0, num(input.batt_charge_reserve_lt25_a, 150)), + dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_lt25_a, -3)), + dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_lt25_a, -8)), + chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_lt25_a, 150)), softToleranceMin: Math.max(0, num(input.batt_soft_tol_lt25_min, 1)), hardToleranceSec: Math.max(0, num(input.batt_hard_tol_lt25_sec, 2)), recoveryMin: Math.max(0, num(input.batt_recovery_lt25_min, 15)), diff --git a/tests/golden/scenarios.mjs b/tests/golden/scenarios.mjs index f45b281..947322f 100644 --- a/tests/golden/scenarios.mjs +++ b/tests/golden/scenarios.mjs @@ -2439,4 +2439,74 @@ export const scenarios = [ sessionCommittedService: null, }, }, + // ======== MISE A L'ECHELLE DU PARC (12/09/2026) ======== + // Les bandes de politique batterie sont en amperes absolus, decrivant le parc + // de 4 modules. Ajouter 4 US5000 (soit 12 equivalents US2000C) doit les + // mettre a l'echelle, sinon le nouveau parc reste bride au niveau de l'ancien. + { + id: 'parc-double-decharge-toleree', + label: "Parc porte a 12 equivalents (4 US2000C + 4 US5000), BMS declarant 300 A : les -120 A qui arretaient tout a 4 modules deviennent tolerables", + time: AFTERNOON, + overrides: { + evcs_vehicle_connected: 'on', evcs_device_connected: 'on', + evcs_charging_switch: 'on', control_latch: 'on', charge_permission_now: 'on', + last_start_at: '2026-08-08 14:00:00', + soc_percent: '94', + evcs_current_a: '20', evcs_set_current_a: '20', evcs_command_current_a: '20', + evcs_ac_power_w: '3600', + pv_power_w: '1000', pv_power_10m_avg_w: '6000', pv_trend_w: '0', + house_ac_power_w: '9000', vebus_ac_out_l1_power_w: '9000', + battery_current_a: '-120', + modules_en_service: '12', + bms_max_discharge_current_a: '300', bms_max_charge_current_a: '300', + }, + expect: { + profile: 'outside_window', + state: 'charging_step_down_system_cap', + }, + }, + { + id: 'parc-double-plafond-bms', + label: "CONTREFACTUEL — parc declare a 12 mais le BMS n'autorise que 100 A (cellule faible, cablage) : le plafond BMS prime, -120 A reste un arret dur", + time: AFTERNOON, + overrides: { + evcs_vehicle_connected: 'on', evcs_device_connected: 'on', + evcs_charging_switch: 'on', control_latch: 'on', charge_permission_now: 'on', + last_start_at: '2026-08-08 14:00:00', + soc_percent: '94', + evcs_current_a: '20', evcs_set_current_a: '20', evcs_command_current_a: '20', + evcs_ac_power_w: '3600', + pv_power_w: '1000', pv_power_10m_avg_w: '6000', pv_trend_w: '0', + house_ac_power_w: '9000', vebus_ac_out_l1_power_w: '9000', + battery_current_a: '-120', + modules_en_service: '12', + bms_max_discharge_current_a: '100', bms_max_charge_current_a: '100', + }, + expect: { + profile: 'outside_window', + state: 'battery_current_hard_stop', + decision: 'stop_hard', + }, + }, + { + id: 'parc-non-declare-comportement-inchange', + label: "CONTREFACTUEL — aucun parc declare, aucune limite BMS lisible : echelle 1, plafond inactif, comportement d'avant ce chantier", + time: AFTERNOON, + overrides: { + evcs_vehicle_connected: 'on', evcs_device_connected: 'on', + evcs_charging_switch: 'on', control_latch: 'on', charge_permission_now: 'on', + last_start_at: '2026-08-08 14:00:00', + soc_percent: '94', + evcs_current_a: '20', evcs_set_current_a: '20', evcs_command_current_a: '20', + evcs_ac_power_w: '3600', + pv_power_w: '1000', pv_power_10m_avg_w: '6000', pv_trend_w: '0', + house_ac_power_w: '9000', vebus_ac_out_l1_power_w: '9000', + battery_current_a: '-120', + }, + expect: { + profile: 'outside_window', + state: 'battery_current_hard_stop', + decision: 'stop_hard', + }, + }, ]; diff --git a/workflows/evcs-surplus-controller-v2.6.json b/workflows/evcs-surplus-controller-v2.6.json index 74f9238..49f0b4a 100644 --- a/workflows/evcs-surplus-controller-v2.6.json +++ b/workflows/evcs-surplus-controller-v2.6.json @@ -94,7 +94,7 @@ }, { "parameters": { - "jsCode": "function num(v, fallback = NaN) {\n const n = Number.parseFloat(v);\n return Number.isFinite(n) ? n : fallback;\n}\n\nfunction low(v) {\n return (v ?? '').toString().trim().toLowerCase();\n}\n\nfunction clamp(v, min, max) {\n return Math.min(Math.max(v, min), max);\n}\n\nfunction round1(v) {\n return Math.round(v * 10) / 10;\n}\n\nfunction round2(v) {\n return Math.round(v * 100) / 100;\n}\n\nfunction to2(n) {\n return String(n).padStart(2, '0');\n}\n\nfunction parseMaybeJson(v) {\n if (typeof v !== 'string') return v;\n try {\n return JSON.parse(v);\n } catch {\n return v;\n }\n}\n\nfunction extractSnapshot(input) {\n if (typeof input === 'string') return parseMaybeJson(input);\n if (input?.data && typeof input.data === 'string') return parseMaybeJson(input.data);\n if (input?.body && typeof input.body === 'string') return parseMaybeJson(input.body);\n if (input?.data && typeof input.data === 'object') return input.data;\n if (input?.body && typeof input.body === 'object') return input.body;\n return input;\n}\n\nfunction parseTimeToMinutes(v, fallback = null) {\n const s = (v ?? '').toString().trim();\n const m = s.match(/^(\\d{1,2}):(\\d{2})(?::(\\d{2}))?$/);\n if (!m) return fallback;\n\n const hh = Number(m[1]);\n const mm = Number(m[2]);\n\n if (!Number.isFinite(hh) || !Number.isFinite(mm)) return fallback;\n return (hh % 24) * 60 + mm;\n}\n\nfunction getParisParts(ms = Date.now()) {\n const fmt = new Intl.DateTimeFormat('fr-FR', {\n timeZone: 'Europe/Paris',\n year: 'numeric',\n month: '2-digit',\n day: '2-digit',\n hour: '2-digit',\n minute: '2-digit',\n second: '2-digit',\n hour12: false,\n });\n\n const parts = Object.fromEntries(\n fmt.formatToParts(new Date(ms))\n .filter(p => p.type !== 'literal')\n .map(p => [p.type, p.value])\n );\n\n const hour = Number(parts.hour) === 24 ? 0 : Number(parts.hour);\n const date = `${parts.year}-${parts.month}-${parts.day}`;\n const stamp = `${date} ${to2(hour)}:${parts.minute}:${parts.second}`;\n\n return {\n year: Number(parts.year),\n month: Number(parts.month),\n day: Number(parts.day),\n hour,\n minute: Number(parts.minute),\n second: Number(parts.second),\n date,\n stamp,\n minNow: hour * 60 + Number(parts.minute),\n };\n}\n\nfunction getTzOffsetMs(utcTs, timeZone = 'Europe/Paris') {\n const dtf = new Intl.DateTimeFormat('en-US', {\n timeZone,\n year: 'numeric',\n month: '2-digit',\n day: '2-digit',\n hour: '2-digit',\n minute: '2-digit',\n second: '2-digit',\n hour12: false,\n });\n\n const parts = Object.fromEntries(\n dtf.formatToParts(new Date(utcTs))\n .filter(p => p.type !== 'literal')\n .map(p => [p.type, p.value])\n );\n\n const asIfUtc = Date.UTC(\n Number(parts.year),\n Number(parts.month) - 1,\n Number(parts.day),\n Number(parts.hour) === 24 ? 0 : Number(parts.hour),\n Number(parts.minute),\n Number(parts.second)\n );\n\n const d = new Date(utcTs);\n const actualUtc = Date.UTC(\n d.getUTCFullYear(),\n d.getUTCMonth(),\n d.getUTCDate(),\n d.getUTCHours(),\n d.getUTCMinutes(),\n d.getUTCSeconds()\n );\n\n return asIfUtc - actualUtc;\n}\n\nfunction parseParisStampToMs(s) {\n const text = (s ?? '').toString().trim();\n const m = text.match(/^(\\d{4})-(\\d{2})-(\\d{2}) (\\d{2}):(\\d{2}):(\\d{2})$/);\n if (!m) return null;\n\n const y = Number(m[1]);\n const mo = Number(m[2]);\n const d = Number(m[3]);\n const h = Number(m[4]);\n const mi = Number(m[5]);\n const se = Number(m[6]);\n\n if (![y, mo, d, h, mi, se].every(Number.isFinite)) return null;\n\n const guessUtc = Date.UTC(y, mo - 1, d, h, mi, se);\n const off1 = getTzOffsetMs(guessUtc, 'Europe/Paris');\n let ts = guessUtc - off1;\n const off2 = getTzOffsetMs(ts, 'Europe/Paris');\n\n if (off2 !== off1) ts = guessUtc - off2;\n return ts;\n}\n\nfunction cleanText(v, fallback = '') {\n const s = (v ?? '').toString().trim();\n const x = s.toLowerCase();\n if (['unknown', 'unavailable', 'none', 'null', 'undefined'].includes(x)) return fallback;\n return s;\n}\n\n// P11 (12/08/2026) : durée de charge EVCS \"1h 49m 53s\" / \"8m 27s\" / \"0s\"\n// → secondes. Repart de 0 à chaque NOUVELLE connexion physique d'un véhicule\n// (débranchement JEEP → branchement VW) → signal de reset du collant \"plein\".\nfunction parseChargingTimeToSec(s) {\n const t = (s ?? '').toString().toLowerCase();\n if (!t) return null;\n let sec = 0;\n let matched = false;\n const h = t.match(/(\\d+)\\s*h/); if (h) { sec += Number(h[1]) * 3600; matched = true; }\n const m = t.match(/(\\d+)\\s*m/); if (m) { sec += Number(m[1]) * 60; matched = true; }\n const s2 = t.match(/(\\d+)\\s*s/); if (s2){ sec += Number(s2[1]); matched = true; }\n return matched ? sec : null;\n}\n\n// Advisor IA : input_text.evcs_advisor_last_run au format \"DD/MM HH:mm\"\n// (pas d'année). On suppose l'année courante ; si le résultat est dans le\n// futur (> 1 jour), c'est un passage d'année → on retire un an.\nfunction parseAdvisorRunToMs(s) {\n const m = (s ?? '').toString().trim().match(/^(\\d{2})\\/(\\d{2}) (\\d{2}):(\\d{2})$/);\n if (!m) return null;\n\n const nowMsLocal = Date.now();\n const year = Number(\n new Intl.DateTimeFormat('fr-FR', { timeZone: 'Europe/Paris', year: 'numeric' })\n .format(new Date(nowMsLocal))\n );\n\n const build = (y) => {\n const guessUtc = Date.UTC(y, Number(m[2]) - 1, Number(m[1]), Number(m[3]), Number(m[4]), 0);\n const off1 = getTzOffsetMs(guessUtc, 'Europe/Paris');\n let ts = guessUtc - off1;\n const off2 = getTzOffsetMs(ts, 'Europe/Paris');\n if (off2 !== off1) ts = guessUtc - off2;\n return ts;\n };\n\n let ts = build(year);\n if (ts - nowMsLocal > 24 * 3600 * 1000) ts = build(year - 1);\n return ts;\n}\n\nfunction finiteOrNull(v) {\n return Number.isFinite(v) ? v : null;\n}\n\nconst raw = $input.first().json;\nconst input = extractSnapshot(raw);\n\nconst nowMs = Date.now();\nconst now = getParisParts(nowMs);\n\nconst CFG = {\n mobileNotifyDomain: 'notify',\n mobileNotifyService: 'mobile_app_iphone_16_de_tt',\n\n // 03/09/2026 — valeur MESUREE (576 paliers de SOC sur 8 jours,\n // tools/mesure-courbe-batterie.mjs) : 0,169 kWh par point au-dessus de 33 %,\n // soit 16,9 kWh. Le 17,5 precedent etait une valeur de plaque.\n // NB : sous 33 % un point ne vaut plus que 0,097 kWh. Cette constante ne sert\n // ici qu'a des ecarts SOC -> cible, tous deux au-dessus du genou. Si un calcul\n // devait un jour traverser le genou, il faut la COURBE (src/energy-balance/\n // BALANCE.js) et non cette constante.\n // 16,9 kWh mesures sur SEPT modules (§41), soit 2,414 kWh par module. Le parc\n // ayant change deux fois en une semaine, le nombre de modules se LIT au lieu\n // d'etre code : `input_number.evcs_balance_modules_en_service`, le meme helper\n // que le bilan energetique — les deux decrivent forcement le meme parc.\n // Absent ou illisible => 7, donc aucun changement tant que personne ne l'ecrit.\n batteryUsableCapacityKwh: 2.414 * (() => {\n const n = Number(input.modules_en_service);\n return Number.isFinite(n) && n >= 1 && n <= 16 ? n : 7;\n })(),\n nominalAcVoltageV: 230,\n evcsDedicatedMaxW: 4900,\n systemReserveW: 300,\n\n vebusDcVoltageSoftFloorV: 49.0,\n vebusDcVoltageHardFloorV: 48.6,\n\n departurePriorityWindowMinutes: 240,\n sampleSeconds: 30,\n\n cloudDebtRecoveryThresholdKwh: 0.05,\n cloudDebtMeaningfulThresholdKwh: 0.01,\n};\n\n// =====================================================\n// PARSED SNAPSHOT\n// =====================================================\nconst parsed = {\n soc: clamp(num(input.soc_percent, 0), 0, 100),\n batteryCurrentA: num(input.battery_current_a, 0),\n\n pvPowerW: Math.max(0, num(input.pv_power_w, 0)),\n\n // MODE DE FONCTIONNEMENT DES CHARGEURS SOLAIRES (03/09/2026)\n // Chaque tracker declare lui-meme s'il est a son point de puissance maximale\n // ('mppt_active' : il donne tout ce qu'il a) ou s'il se retient\n // ('voltage_current_limited', 'off' : il y a de la ressource REFUSEE).\n // Lectures inexploitables (integration muette) => listes vides => les gardes\n // aval retombent sur le comportement anterieur. On ne devine pas un etat.\n ...(() => {\n const modes = String(input.mppt_operation_modes || '')\n .split(',')\n .map(s => s.trim().toLowerCase())\n .filter(s => s !== '' && s !== 'unavailable' && s !== 'unknown');\n const atMaxPower = modes.filter(s => s === 'mppt_active').length;\n // Un chargeur qui SE RETIENT (`voltage_current_limited`) prouve qu'il reste\n // de la ressource refusee. Un chargeur `off` n'a rien a donner : la nuit,\n // tous le sont. `mpptHoldingBackCount` confond les deux, ce qui est sans\n // consequence pour la garde de provocation solaire (§37, demarrage de jour\n // seulement) mais ferait descendre la consigne reseau au crepuscule si on\n // s'en servait ici — un oscillateur de plus. On compte donc separement ce\n // qui se declare BRIDE, et tout libelle inconnu retombe du cote prudent\n // (pas de ressource refusee, donc comportement anterieur).\n const limited = modes.filter(s => s.includes('limited')).length;\n return {\n mpptReadableCount: modes.length,\n mpptAtMaxPowerCount: atMaxPower,\n mpptHoldingBackCount: modes.length - atMaxPower,\n mpptLimitedCount: limited,\n };\n })(),\n pvPowerAvg10mW: Math.max(0, num(input.pv_power_10m_avg_w, num(input.pv_power_w, 0))),\n pvTrendW: num(input.pv_trend_w, 0),\n\n houseAcPowerW: Math.max(0, num(input.house_ac_power_w, 0)),\n houseAcPowerPrevW: Math.max(0, num(input.house_ac_power_prev_w, num(input.house_ac_power_w, 0))),\n gridPowerW: num(input.grid_power_w, 0),\n\n gridIsOn: low(input.grid_state || 'off') === 'on',\n acInAvailable: num(input.victron_acin1_available ?? input.ac_in1_available, 0) === 1,\n\n // Consigne de puissance réseau de l'ESS, lue telle qu'elle est appliquée.\n // C'est ELLE qui décide si un contacteur fermé sert à quelque chose : au-dessus\n // du SOC minimal, l'ESS en autoconsommation ne prélève que cette puissance et\n // laisse la batterie porter le reste. Nuit du 01/09 : contacteur fermé,\n // consigne 50 W, batterie à -803 W pour 761 W de maison.\n gridSetpointW: num(input.grid_setpoint_w, NaN),\n gridAvailable:\n (low(input.grid_state || 'off') === 'on') ||\n (num(input.victron_acin1_available ?? input.ac_in1_available, 0) === 1),\n\n // FENETRE D'ETABLISSEMENT (31/08/2026) — age, en secondes, de la derniere\n // transition du reseau. On retient la plus RECENTE des deux sources : la\n // presence physique AC-IN (celle qui declenche reellement le transitoire) et\n // le contacteur (qui peut bouger sans qu'AC-IN suive, disjoncteur ouvert).\n // Horodatage absent ou nul => age tres grand => aucune fenetre, comportement\n // historique. On ne devine jamais une transition qu'on n'a pas observee.\n gridTransitionAgeSec: (() => {\n const ts = Math.max(\n num(input.acin1_last_changed_ts, 0),\n num(input.grid_switch_last_changed_ts, 0)\n );\n if (!(ts > 0)) return Number.POSITIVE_INFINITY;\n return Math.max(0, (nowMs / 1000) - ts);\n })(),\n\n todayRemainingKwh: Math.max(0, num(input.today_remaining_kwh, 0)),\n tomorrowKwh: Math.max(0, num(input.tomorrow_kwh, 0)),\n\n evcsDeviceConnected: low(input.evcs_device_connected || 'off') === 'on',\n evcsVehicleConnected: low(input.evcs_vehicle_connected || 'off') === 'on',\n evcsStatusRaw: cleanText(input.evcs_status_raw),\n evcsModeRaw: [\n input.evcs_mode_sensor,\n input.evcs_mode_fallback,\n input.evcs_mode\n ]\n .map(v => cleanText(v))\n .find(v => v) || 'unknown',\n\n evcsSetCurrentA: num(input.evcs_set_current_a, NaN),\n evcsCommandCurrentA: num(input.evcs_command_current_a, NaN),\n\n // Mesure réelle côté borne\n evcsCurrentA: Math.max(0, num(input.evcs_current_a, 0)),\n evcsCurrentRealA: Math.max(0, num(input.evcs_current_a, 0)),\n\n evcsAcPowerW: Math.max(0, num(input.evcs_ac_power_w, 0)),\n evcsChargingTimeSec: parseChargingTimeToSec(input.evcs_charging_time),\n // Energie deja livree par la session EN COURS (kWh). Le capteur de la borne\n // s'appelle \"last_session_energy\" mais il suit la session courante et repart\n // de zero a chaque nouvelle connexion (verifie le 07/09/2026 : 0 -> 0,1 -> 0,2\n // ... pendant la charge). Sert a juger la credibilite d'un statut \"charged\".\n evcsSessionEnergyKwh: Math.max(0, num(input.evcs_session_energy_kwh, 0)),\n evcsChargingSwitchOn: low(input.evcs_charging_switch || 'off') === 'on',\n evcsAutoStartSwitchOn: low(input.evcs_auto_start_switch || 'off') === 'on',\n\n controllerEnabled: low(input.controller_enabled || 'off') === 'on',\n notificationsEnabled: low(input.notifications_enabled || 'off') === 'on',\n hardStopEnabledLegacy: low(input.hard_stop_enabled || 'off') === 'on',\n chargePermissionNow: low(input.charge_permission_now || 'off') === 'on',\n controlLatch: low(input.control_latch || 'off') === 'on',\n departurePriorityEnabled: low(input.departure_priority_enabled || 'off') === 'on',\n forecastModeEnabled: low(input.forecast_mode_enabled || 'off') === 'on',\n\n evcsPriorityManualOverride: low(input.evcs_priority_manual_override || 'off') === 'on',\n evcsPriorityManualMode: cleanText(input.evcs_priority_manual_mode || 'normal', 'normal').toLowerCase(),\n evcsPriorityManualReason: cleanText(input.evcs_priority_manual_reason),\n\n vebusOverload: low(input.vebus_overload || 'off') === 'on',\n vebusL1Overload: low(input.vebus_l1_overload || 'off') === 'on',\n vebusLowBattery: low(input.vebus_low_battery || 'off') === 'on',\n vebusL1LowBattery: low(input.vebus_l1_low_battery || 'off') === 'on',\n\n vebusAcOutPowerW: Math.max(0, num(input.vebus_ac_out_l1_power_w, 0)),\n vebusAcOutCurrentA: Math.max(0, num(input.vebus_ac_out_l1_current_a, 0)),\n vebusAcOutVoltageV: num(input.vebus_ac_out_l1_voltage_v, CFG.nominalAcVoltageV),\n\n vebusDcVoltageV: num(input.vebus_dc_voltage_v, NaN),\n vebusDcCurrentA: num(input.vebus_dc_current_a, NaN),\n vebusDcPowerW: num(input.vebus_dc_power_w, NaN),\n\n vebusState: num(input.vebus_state, NaN),\n vebusMainState: num(input.vebus_main_state, NaN),\n};\n\nparsed.evcsModeIsAuto = low(parsed.evcsModeRaw).includes('auto');\n\n// =====================================================\n// PARAMETERS\n// =====================================================\nconst params = {\n userStrategyRaw: input.victron_evcs_strategy || 'auto_solar',\n\n targetCurrentAutoA: clamp(num(input.target_current_auto_a, 6), 0, 32),\n pvStartMinW: Math.max(0, num(input.pv_start_min_w, 1800)),\n pvHoldMinW: Math.max(0, num(input.pv_hold_min_w, 1200)),\n houseAcHeadroomW: Math.max(0, num(input.house_ac_headroom_w, 1200)),\n\n batteryDischargeSoftA: num(input.battery_discharge_soft_a, -5),\n batteryDischargeHardA: num(input.battery_discharge_hard_a, -15),\n batteryReserveUpA: Math.max(0, num(input.battery_reserve_up_a, 8)),\n batteryNeutralBandA: Math.max(0, num(input.battery_neutral_band_a, 3)),\n\n socStartMin: clamp(num(input.soc_start_min, 60), 0, 100),\n socStopMin: clamp(num(input.soc_stop_min, 35), 0, 100),\n\n currentMinA: clamp(num(input.current_min_a, 6), 6, 32),\n currentMaxAutoA: clamp(\n num(input.current_max_auto_a, 16),\n clamp(num(input.current_min_a, 6), 6, 32),\n 32\n ),\n gridCurrentMaxA: clamp(num(input.grid_current_max_a, 20), 6, 32),\n currentStepUpA: clamp(num(input.current_step_up_a, 1), 1, 5),\n currentStepDownA: clamp(num(input.current_step_down_a, 2), 1, 8),\n\n currentChangeCooldownSeconds: Math.max(5, num(input.current_change_cooldown_seconds, 60)),\n minRunMinutes: Math.max(0, num(input.min_run_minutes, 3)),\n minStopMinutes: Math.max(0, num(input.min_stop_minutes, 10)),\n\n requiredEnergyKwh: Math.max(0, num(input.required_energy_kwh, 0)),\n socComfortTarget: clamp(num(input.soc_comfort_target, 85), 0, 100),\n endOfDaySocGuard: clamp(num(input.end_of_day_soc_guard, 85), 0, 100),\n baseLoadRemainingKwh: Math.max(0, num(input.base_load_remaining_kwh, 0)),\n flexibleSafetyMarginKwh: Math.max(0, num(input.flexible_safety_margin_kwh, 0)),\n endOfDaySocTarget: clamp(num(input.end_of_day_soc_target, 85), 0, 100),\n\n acLoadsMaxSafeW: Math.max(0, num(input.ac_loads_max_safe_w, 8500)),\n batteryFullSoc: clamp(num(input.battery_full_soc, 90), 0, 100),\n batteryFullForecastMinKwh: Math.max(0, num(input.battery_full_forecast_min_kwh, 8)),\n forecastCommitSocFloor: clamp(num(input.forecast_commit_soc_floor, 35), 0, 100),\n forecastCommitMinKwh: Math.max(0, num(input.forecast_commit_min_kwh, 25)),\n\n cloudDebtPrevKwh: Math.max(0, num(input.cloud_debt_kwh, 0)),\n cloudDebtMaxKwh: Math.max(0.05, num(input.cloud_debt_max_kwh, 1.2)),\n cloudToleranceMinutes: Math.max(1, num(input.cloud_tolerance_minutes, 20)),\n\n // P9 (09/08/2026) : deux véhicules alternent sur la borne.\n // Le sélecteur input_select.victron_evcs_vehicle choisit l'heure de départ\n // effective : VW = victron_evcs_departure_time (~08:50),\n // JEEP = victron_evcs_departure_time_jeep (~06:30).\n selectedVehicle: cleanText(input.evcs_vehicle, 'VW'),\n departureTimeMin:\n low(input.evcs_vehicle || 'vw') === 'jeep'\n ? parseTimeToMinutes(\n input.departure_time_jeep,\n parseTimeToMinutes(input.departure_time, null)\n )\n : parseTimeToMinutes(input.departure_time, null),\n allowGridDepartureUrgent: low(input.allow_grid_departure_urgent || 'off') === 'on',\n dayStartTimeMin: parseTimeToMinutes(input.day_start_time, 7 * 60 + 30),\n dayStopTimeMin: parseTimeToMinutes(input.day_stop_time, 20 * 60 + 30),\n\n hcNightStartMin: parseTimeToMinutes(input.hc_night_start_time, 23 * 60),\n hcNightStopMin: parseTimeToMinutes(input.hc_night_stop_time, 6 * 60),\n morningStartMin: parseTimeToMinutes(\n input.morning_start_time,\n parseTimeToMinutes(input.day_start_time, 7 * 60 + 30)\n ),\n morningStopMin: parseTimeToMinutes(input.morning_stop_time, 11 * 60),\n hcMiddayStartMin: parseTimeToMinutes(input.hc_midday_start_time, 12 * 60 + 21),\n hcMiddayStopMin: parseTimeToMinutes(input.hc_midday_stop_time, 14 * 60 + 21),\n eveningStartMin: parseTimeToMinutes(input.evening_start_time, 17 * 60),\n eveningStopMin: parseTimeToMinutes(\n input.evening_stop_time,\n parseTimeToMinutes(input.day_stop_time, 20 * 60 + 30)\n ),\n\n allowGridHcNight: low(input.allow_grid_hc_night || 'off') === 'on',\n allowGridHcMidday: low(input.allow_grid_hc_midday || 'off') === 'on',\n\n // Advisor IA — premier câblage réel (09/08/2026, HANDOFF §20) :\n // cible SOC matin recommandée, appliquée UNIQUEMENT si le toggle est ON.\n // Garde-fous consommés dans WINDOWS_SOURCEV2 (statut ok + fraîcheur + bornes).\n advisorApplyNightTarget: low(input.advisor_apply_night_target || 'off') === 'on',\n advisorNightTargetSocPct: num(input.advisor_night_target_soc, NaN),\n advisorStatusOk: cleanText(input.advisor_status).toLowerCase() === 'ok',\n advisorLastRunMs: parseAdvisorRunToMs(cleanText(input.advisor_last_run)),\n\n // BILAN ENERGETIQUE (03/09/2026). Meme format d'horodatage que l'advisor\n // (\"DD/MM HH:mm\"), d'ou la reutilisation du parseur.\n balanceRequiredSocPct: num(input.balance_required_soc, NaN),\n balanceEnergyToCoverKwh: num(input.balance_energy_to_cover_kwh, NaN),\n balanceStatusOk: cleanText(input.balance_status).toLowerCase() === 'ok',\n balanceLastRunMs: parseAdvisorRunToMs(cleanText(input.balance_last_run)),\n\n // Duree de la fenetre d'etablissement. Valeur mesuree le 31/08/2026 : le\n // transitoire de fermeture dure ~150 s (import 1985 -> 25 W et 2600 -> 52 W,\n // deux campagnes), on prend 180 s de marge. Reglable sans redeploiement via\n // input_number.evcs_grid_settle_seconds ; absent => 180.\n gridSettleSeconds: clamp(num(input.grid_settle_seconds, 180), 0, 900),\n\n // Consigne réseau au repos. 50 W est le défaut Victron (légèrement positif\n // pour ne jamais injecter), pas une valeur choisie ici.\n // CONSIGNE DE REPOS : 200 W et non plus 50 (04/09/2026).\n // 50 W etait le defaut Victron. Mesure sur la nuit du 03-04/09, 12 074\n // echantillons du point de raccordement : 17 % sont NEGATIFS, mediane -18 W,\n // excursions jusqu'a -356 W, episodes de 35 s au plus. Ce n'est pas de\n // l'injection — la batterie se dechargeait a 744 W au meme moment — c'est le\n // regulateur qui chasse autour d'une cible trop proche de zero. A 200 W le\n // point de fonctionnement reste positif sur l'essentiel des excursions.\n // ⚠️ Ne supprime pas les pointes les plus fortes : une excursion de -356 W\n // passerait encore sous zero. Reduit leur nombre, ne les annule pas.\n // CONSIGNE DE REPOS : 50 -> 200 (04/09) -> 700 (06/09).\n //\n // Elle ne s'applique que contacteur FERME sans session reseau EVCS — donc\n // apres une coupure sur SOC bas, ou apres une fermeture par la regle de\n // protection du parc. Contacteur ouvert, elle n'a aucun effet.\n //\n // A 200 W, une plaque chauffante qui cycle fait passer le point de\n // fonctionnement sous zero : mesure du 06/09 sur la fenetre 12:07-12:22,\n // 9 % des echantillons negatifs, minimum -477 W, mediane des negatifs\n // -146 W. Le regulateur ne rattrape pas assez vite un delestage brutal de\n // ~1 kW. A 700 W toute la courbe monte de 500 W : minimum +23 W, plus aucune\n // excursion negative sur cette fenetre.\n //\n // Le surcout est faible et va dans le bon sens : les DEUX seules raisons de\n // fermer le contacteur sans session EVCS sont « la batterie est a son\n // plancher » et « la maison demande plus que le parc ne sait donner ». Dans\n // les deux cas on VEUT que le reseau contribue plus que 200 W.\n //\n // ⚠️ Ne corrige PAS les gros a-coups. Le 06/09 a 13:41:40, le debranchement\n // du vehicule a supprime 2,2 kW d'un coup alors que la batterie, a 93 % de\n // SOC, n'absorbait rien et que le MPPT produisait 4 kW : -2 819 W pendant\n // plus de deux minutes, le temps que le systeme bride la production. Aucune\n // consigne n'absorbe cela. Ce qui l'evite est la correction du meme jour sur\n // la regle de protection (elle porte desormais sur `maison - PV`) : avec une\n // demande sur le parc de 741 W, le contacteur n'aurait pas ete ferme, et\n // sans reseau il n'y a rien ou injecter.\n gridSetpointIdleW: clamp(num(input.grid_setpoint_idle_w, 700), 0, 1500),\n\n probeEnabled: low(input.probe_enabled || 'off') === 'on',\n probeMinutes: Math.max(1, num(input.probe_minutes, 3)),\n probeRetryMinutes: Math.max(5, num(input.probe_retry_minutes, 45)),\n probeCurrentA: clamp(\n num(input.probe_current_a, clamp(num(input.current_min_a, 10), 6, 32)),\n clamp(num(input.current_min_a, 10), 6, 32),\n clamp(num(input.current_max_auto_a, 16), clamp(num(input.current_min_a, 10), 6, 32), 32)\n ),\n\n gridBatterySoftA: num(input.grid_battery_soft_a, -3),\n gridBatteryHardA: num(input.grid_battery_hard_a, -6),\n\n morningProbePvAvgMinW: Math.max(0, num(input.morning_probe_pv_avg_min_w, 1500)),\n morningProbePvTrendMinW: num(input.morning_probe_pv_trend_min_w, 0),\n middayProbePvAvgMinW: Math.max(0, num(input.midday_probe_pv_avg_min_w, 1200)),\n\n morningSocMin: clamp(num(input.morning_soc_min, 35), 0, 100),\n middaySocMin: clamp(num(input.midday_soc_min, 75), 0, 100),\n eveningSocStartMin: clamp(num(input.evening_soc_start_min, 85), 0, 100),\n eveningSocStopMin: clamp(num(input.evening_soc_stop_min, 80), 0, 100),\n\n morningBatteryMaxDischargeA: num(input.morning_battery_max_discharge_a, -20),\n middayBatteryMaxDischargeA: num(input.midday_battery_max_discharge_a, -40),\n eveningBatteryMaxDischargeA: num(input.evening_battery_max_discharge_a, -30),\n\n // =====================================================\n // EVCS NIGHT ENGINE — NEW PARAMETERS\n // =====================================================\n evcsNightBatteryHardFloorPct: clamp(\n num(input.evcs_night_battery_hard_floor_pct, 22),\n 0,\n 100\n ),\n\n evcsNightStrongForecastKwh: Math.max(\n 0,\n num(input.evcs_night_strong_forecast_kwh, 18)\n ),\n\n evcsNightMediumForecastKwh: Math.max(\n 0,\n num(input.evcs_night_medium_forecast_kwh, 10)\n ),\n\n evcsNightTargetStrongForecastPct: clamp(\n num(input.evcs_night_target_strong_forecast_pct, 35),\n 0,\n 100\n ),\n\n evcsNightTargetMediumForecastPct: clamp(\n num(input.evcs_night_target_medium_forecast_pct, 55),\n 0,\n 100\n ),\n\n evcsNightTargetWeakForecastPct: clamp(\n num(input.evcs_night_target_weak_forecast_pct, 85),\n 0,\n 100\n ),\n\n evcsNightBatteryRecoveryPowerKw: Math.max(\n 0.1,\n num(input.evcs_night_battery_recovery_power_kw, 2.5)\n ),\n\n evcsNightDepartureSafetyMin: Math.max(\n 0,\n num(input.evcs_night_departure_safety_min, 30)\n ),\n};\n\n// =====================================================\n// HISTORY / PERSISTED HELPERS\n// =====================================================\nconst nightSessionStartSocRaw = num(\n input.evcs_night_session_start_soc ?? input.night_session_start_soc,\n NaN\n);\n\nconst nightSessionStartAtRaw = cleanText(\n input.evcs_night_session_start_at ?? input.night_session_start_at\n);\n\n// =====================================================\n// VEHICLE DEMAND FILTER HISTORY RAW INPUTS\n// =====================================================\nconst evcsNoDemandSinceAtRaw = cleanText(input.evcs_no_demand_since_at);\nconst evcsNoDemandFilterEvalAtRaw = cleanText(input.evcs_no_demand_filter_eval_at);\n\nconst history = {\n lastBlockReason: cleanText(input.last_block_reason, 'none') || 'none',\n blockedUntilAt: cleanText(input.blocked_until),\n probeStartedAt: cleanText(input.probe_started_at),\n lastStartAt: cleanText(input.last_start_at),\n lastStopAt: cleanText(input.last_stop_at),\n lastCurrentChangeAt: cleanText(input.last_current_change_at),\n lastSignature: cleanText(input.last_signature),\n cloudDebtStartedAt: cleanText(input.cloud_debt_started_at),\n evcsPriorityManualUntilAt: cleanText(input.evcs_priority_manual_until),\n\n blockedUntilMs: parseParisStampToMs(cleanText(input.blocked_until)),\n probeStartedMs: parseParisStampToMs(cleanText(input.probe_started_at)),\n lastStartMs: parseParisStampToMs(cleanText(input.last_start_at)),\n lastStopMs: parseParisStampToMs(cleanText(input.last_stop_at)),\n lastCurrentChangeMs: parseParisStampToMs(cleanText(input.last_current_change_at)),\n cloudDebtStartedMsPrev: parseParisStampToMs(cleanText(input.cloud_debt_started_at)),\n\n // DEPASSEMENT SOUPLE BATTERIE (01/09/2026) : horodatage du debut du\n // depassement en cours, ecrit par HA_SERVICE_CALLS_OUTPUT. Vide/illisible\n // => null => aucun depassement en cours, comportement de repli sur.\n nightGridSessionCommittedPrev:\n (input.night_grid_session_committed_prev ?? 'off').toString().trim().toLowerCase() === 'on',\n batterySoftBreachAt: cleanText(input.battery_soft_breach_at),\n batterySoftBreachMsPrev: parseParisStampToMs(cleanText(input.battery_soft_breach_at)),\n evcsPriorityManualUntilMs: parseParisStampToMs(cleanText(input.evcs_priority_manual_until)),\n\n // =====================================================\n // EVCS NIGHT SESSION MEMORY\n // =====================================================\n nightSessionStartSocPct: Number.isFinite(nightSessionStartSocRaw)\n ? clamp(nightSessionStartSocRaw, 0, 100)\n : null,\n\n nightSessionStartAt: nightSessionStartAtRaw || '',\n nightSessionStartMs: parseParisStampToMs(nightSessionStartAtRaw),\n\n // =====================================================\n // VEHICLE DEMAND FILTER PERSISTENCE\n // =====================================================\n evcsDeliveryRatioEma: num(input.evcs_delivery_ratio_ema, NaN),\n evcsDeliveryNoiseEma: num(input.evcs_delivery_noise_ema, NaN),\n evcsNoDemandScoreEma: num(input.evcs_no_demand_score_ema, NaN),\n evcsNoDemandSemanticActive: low(input.evcs_no_demand_semantic_active || 'off') === 'on',\n\n evcsNoDemandSinceAt: evcsNoDemandSinceAtRaw || '',\n evcsNoDemandSinceMs: parseParisStampToMs(evcsNoDemandSinceAtRaw),\n\n evcsNoDemandFilterEvalAt: evcsNoDemandFilterEvalAtRaw || '',\n evcsNoDemandFilterEvalMs: parseParisStampToMs(evcsNoDemandFilterEvalAtRaw),\n};\n\n// =====================================================\n// BATTERY TUNING\n// =====================================================\nconst batteryTune = {\n global: {\n houseSpikeGraceMinutes: Math.max(0, num(input.house_spike_grace_minutes, 10)),\n solarPotentialGraceMinutes: Math.max(0, num(input.solar_potential_grace_minutes, 12)),\n stepUpCooldownSeconds: Math.max(5, num(input.step_up_cooldown_seconds, params.currentChangeCooldownSeconds)),\n stepDownCooldownSeconds: Math.max(5, num(input.step_down_cooldown_seconds, params.currentChangeCooldownSeconds)),\n forceModeAutoRevertMinutes: Math.max(0, num(input.force_mode_auto_revert_minutes, 120)),\n overloadStepDownA: Math.max(1, num(input.overload_step_down_a, 2)),\n overloadHoldSeconds: Math.max(5, num(input.overload_hold_seconds, 30)),\n overloadStopAfterSeconds: Math.max(10, num(input.overload_stop_after_seconds, 120)),\n },\n\n bands: {\n gt90: {\n dischargeSoftA: num(input.batt_discharge_soft_gt90_a, -50),\n dischargeHardA: num(input.batt_discharge_hard_gt90_a, -100),\n chargeReserveA: Math.max(0, num(input.batt_charge_reserve_gt90_a, 5)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_gt90_min, 12)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_gt90_sec, 20)),\n recoveryMin: Math.max(0, num(input.batt_recovery_gt90_min, 6)),\n },\n\n '80_90': {\n dischargeSoftA: num(input.batt_discharge_soft_80_90_a, -40),\n dischargeHardA: num(input.batt_discharge_hard_80_90_a, -80),\n chargeReserveA: Math.max(0, num(input.batt_charge_reserve_80_90_a, 10)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_80_90_min, 10)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_80_90_sec, 20)),\n recoveryMin: Math.max(0, num(input.batt_recovery_80_90_min, 6)),\n },\n\n '60_80': {\n dischargeSoftA: num(input.batt_discharge_soft_60_80_a, -20),\n dischargeHardA: num(input.batt_discharge_hard_60_80_a, -50),\n chargeReserveA: Math.max(0, num(input.batt_charge_reserve_60_80_a, 40)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_60_80_min, 6)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_60_80_sec, 15)),\n recoveryMin: Math.max(0, num(input.batt_recovery_60_80_min, 8)),\n },\n\n '40_60': {\n dischargeSoftA: num(input.batt_discharge_soft_40_60_a, -12),\n dischargeHardA: num(input.batt_discharge_hard_40_60_a, -30),\n chargeReserveA: Math.max(0, num(input.batt_charge_reserve_40_60_a, 70)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_40_60_min, 4)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_40_60_sec, 10)),\n recoveryMin: Math.max(0, num(input.batt_recovery_40_60_min, 10)),\n },\n\n '25_40': {\n dischargeSoftA: num(input.batt_discharge_soft_25_40_a, -5),\n dischargeHardA: num(input.batt_discharge_hard_25_40_a, -15),\n chargeReserveA: Math.max(0, num(input.batt_charge_reserve_25_40_a, 110)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_25_40_min, 2)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_25_40_sec, 5)),\n recoveryMin: Math.max(0, num(input.batt_recovery_25_40_min, 12)),\n },\n\n lt25: {\n dischargeSoftA: num(input.batt_discharge_soft_lt25_a, -3),\n dischargeHardA: num(input.batt_discharge_hard_lt25_a, -8),\n chargeReserveA: Math.max(0, num(input.batt_charge_reserve_lt25_a, 150)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_lt25_min, 1)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_lt25_sec, 2)),\n recoveryMin: Math.max(0, num(input.batt_recovery_lt25_min, 15)),\n },\n },\n};\n\n// =====================================================\n// OPTIONAL DEBUG / SUMMARY\n// =====================================================\nconst evcsNightConfig = {\n batteryHardFloorPct: params.evcsNightBatteryHardFloorPct,\n strongForecastKwh: params.evcsNightStrongForecastKwh,\n mediumForecastKwh: params.evcsNightMediumForecastKwh,\n targetStrongForecastPct: params.evcsNightTargetStrongForecastPct,\n targetMediumForecastPct: params.evcsNightTargetMediumForecastPct,\n targetWeakForecastPct: params.evcsNightTargetWeakForecastPct,\n batteryRecoveryPowerKw: params.evcsNightBatteryRecoveryPowerKw,\n departureSafetyMin: params.evcsNightDepartureSafetyMin,\n sessionStartSocPct: history.nightSessionStartSocPct,\n sessionStartAt: history.nightSessionStartAt || null,\n};\n\nconst vehicleDemandHistoryDebug = {\n evcsDeliveryRatioEma: finiteOrNull(history.evcsDeliveryRatioEma),\n evcsDeliveryNoiseEma: finiteOrNull(history.evcsDeliveryNoiseEma),\n evcsNoDemandScoreEma: finiteOrNull(history.evcsNoDemandScoreEma),\n evcsNoDemandSemanticActive: history.evcsNoDemandSemanticActive,\n evcsNoDemandSinceAt: history.evcsNoDemandSinceAt || null,\n evcsNoDemandSinceMs: finiteOrNull(history.evcsNoDemandSinceMs),\n evcsNoDemandFilterEvalAt: history.evcsNoDemandFilterEvalAt || null,\n evcsNoDemandFilterEvalMs: finiteOrNull(history.evcsNoDemandFilterEvalMs),\n};\n\n// =====================================================\n// OUTPUT\n// =====================================================\nreturn [{\n json: {\n raw,\n input,\n nowMs,\n now,\n cfg: CFG,\n parsed,\n params,\n history,\n batteryTune,\n evcsNightConfig,\n vehicleDemandHistoryDebug,\n }\n}];\n" + "jsCode": "function num(v, fallback = NaN) {\n const n = Number.parseFloat(v);\n return Number.isFinite(n) ? n : fallback;\n}\n\nfunction low(v) {\n return (v ?? '').toString().trim().toLowerCase();\n}\n\nfunction clamp(v, min, max) {\n return Math.min(Math.max(v, min), max);\n}\n\nfunction round1(v) {\n return Math.round(v * 10) / 10;\n}\n\nfunction round2(v) {\n return Math.round(v * 100) / 100;\n}\n\nfunction to2(n) {\n return String(n).padStart(2, '0');\n}\n\nfunction parseMaybeJson(v) {\n if (typeof v !== 'string') return v;\n try {\n return JSON.parse(v);\n } catch {\n return v;\n }\n}\n\nfunction extractSnapshot(input) {\n if (typeof input === 'string') return parseMaybeJson(input);\n if (input?.data && typeof input.data === 'string') return parseMaybeJson(input.data);\n if (input?.body && typeof input.body === 'string') return parseMaybeJson(input.body);\n if (input?.data && typeof input.data === 'object') return input.data;\n if (input?.body && typeof input.body === 'object') return input.body;\n return input;\n}\n\nfunction parseTimeToMinutes(v, fallback = null) {\n const s = (v ?? '').toString().trim();\n const m = s.match(/^(\\d{1,2}):(\\d{2})(?::(\\d{2}))?$/);\n if (!m) return fallback;\n\n const hh = Number(m[1]);\n const mm = Number(m[2]);\n\n if (!Number.isFinite(hh) || !Number.isFinite(mm)) return fallback;\n return (hh % 24) * 60 + mm;\n}\n\nfunction getParisParts(ms = Date.now()) {\n const fmt = new Intl.DateTimeFormat('fr-FR', {\n timeZone: 'Europe/Paris',\n year: 'numeric',\n month: '2-digit',\n day: '2-digit',\n hour: '2-digit',\n minute: '2-digit',\n second: '2-digit',\n hour12: false,\n });\n\n const parts = Object.fromEntries(\n fmt.formatToParts(new Date(ms))\n .filter(p => p.type !== 'literal')\n .map(p => [p.type, p.value])\n );\n\n const hour = Number(parts.hour) === 24 ? 0 : Number(parts.hour);\n const date = `${parts.year}-${parts.month}-${parts.day}`;\n const stamp = `${date} ${to2(hour)}:${parts.minute}:${parts.second}`;\n\n return {\n year: Number(parts.year),\n month: Number(parts.month),\n day: Number(parts.day),\n hour,\n minute: Number(parts.minute),\n second: Number(parts.second),\n date,\n stamp,\n minNow: hour * 60 + Number(parts.minute),\n };\n}\n\nfunction getTzOffsetMs(utcTs, timeZone = 'Europe/Paris') {\n const dtf = new Intl.DateTimeFormat('en-US', {\n timeZone,\n year: 'numeric',\n month: '2-digit',\n day: '2-digit',\n hour: '2-digit',\n minute: '2-digit',\n second: '2-digit',\n hour12: false,\n });\n\n const parts = Object.fromEntries(\n dtf.formatToParts(new Date(utcTs))\n .filter(p => p.type !== 'literal')\n .map(p => [p.type, p.value])\n );\n\n const asIfUtc = Date.UTC(\n Number(parts.year),\n Number(parts.month) - 1,\n Number(parts.day),\n Number(parts.hour) === 24 ? 0 : Number(parts.hour),\n Number(parts.minute),\n Number(parts.second)\n );\n\n const d = new Date(utcTs);\n const actualUtc = Date.UTC(\n d.getUTCFullYear(),\n d.getUTCMonth(),\n d.getUTCDate(),\n d.getUTCHours(),\n d.getUTCMinutes(),\n d.getUTCSeconds()\n );\n\n return asIfUtc - actualUtc;\n}\n\nfunction parseParisStampToMs(s) {\n const text = (s ?? '').toString().trim();\n const m = text.match(/^(\\d{4})-(\\d{2})-(\\d{2}) (\\d{2}):(\\d{2}):(\\d{2})$/);\n if (!m) return null;\n\n const y = Number(m[1]);\n const mo = Number(m[2]);\n const d = Number(m[3]);\n const h = Number(m[4]);\n const mi = Number(m[5]);\n const se = Number(m[6]);\n\n if (![y, mo, d, h, mi, se].every(Number.isFinite)) return null;\n\n const guessUtc = Date.UTC(y, mo - 1, d, h, mi, se);\n const off1 = getTzOffsetMs(guessUtc, 'Europe/Paris');\n let ts = guessUtc - off1;\n const off2 = getTzOffsetMs(ts, 'Europe/Paris');\n\n if (off2 !== off1) ts = guessUtc - off2;\n return ts;\n}\n\nfunction cleanText(v, fallback = '') {\n const s = (v ?? '').toString().trim();\n const x = s.toLowerCase();\n if (['unknown', 'unavailable', 'none', 'null', 'undefined'].includes(x)) return fallback;\n return s;\n}\n\n// P11 (12/08/2026) : durée de charge EVCS \"1h 49m 53s\" / \"8m 27s\" / \"0s\"\n// → secondes. Repart de 0 à chaque NOUVELLE connexion physique d'un véhicule\n// (débranchement JEEP → branchement VW) → signal de reset du collant \"plein\".\nfunction parseChargingTimeToSec(s) {\n const t = (s ?? '').toString().toLowerCase();\n if (!t) return null;\n let sec = 0;\n let matched = false;\n const h = t.match(/(\\d+)\\s*h/); if (h) { sec += Number(h[1]) * 3600; matched = true; }\n const m = t.match(/(\\d+)\\s*m/); if (m) { sec += Number(m[1]) * 60; matched = true; }\n const s2 = t.match(/(\\d+)\\s*s/); if (s2){ sec += Number(s2[1]); matched = true; }\n return matched ? sec : null;\n}\n\n// Advisor IA : input_text.evcs_advisor_last_run au format \"DD/MM HH:mm\"\n// (pas d'année). On suppose l'année courante ; si le résultat est dans le\n// futur (> 1 jour), c'est un passage d'année → on retire un an.\nfunction parseAdvisorRunToMs(s) {\n const m = (s ?? '').toString().trim().match(/^(\\d{2})\\/(\\d{2}) (\\d{2}):(\\d{2})$/);\n if (!m) return null;\n\n const nowMsLocal = Date.now();\n const year = Number(\n new Intl.DateTimeFormat('fr-FR', { timeZone: 'Europe/Paris', year: 'numeric' })\n .format(new Date(nowMsLocal))\n );\n\n const build = (y) => {\n const guessUtc = Date.UTC(y, Number(m[2]) - 1, Number(m[1]), Number(m[3]), Number(m[4]), 0);\n const off1 = getTzOffsetMs(guessUtc, 'Europe/Paris');\n let ts = guessUtc - off1;\n const off2 = getTzOffsetMs(ts, 'Europe/Paris');\n if (off2 !== off1) ts = guessUtc - off2;\n return ts;\n };\n\n let ts = build(year);\n if (ts - nowMsLocal > 24 * 3600 * 1000) ts = build(year - 1);\n return ts;\n}\n\nfunction finiteOrNull(v) {\n return Number.isFinite(v) ? v : null;\n}\n\nconst raw = $input.first().json;\nconst input = extractSnapshot(raw);\n\nconst nowMs = Date.now();\nconst now = getParisParts(nowMs);\n\nconst CFG = {\n mobileNotifyDomain: 'notify',\n mobileNotifyService: 'mobile_app_iphone_16_de_tt',\n\n // 03/09/2026 — valeur MESUREE (576 paliers de SOC sur 8 jours,\n // tools/mesure-courbe-batterie.mjs) : 0,169 kWh par point au-dessus de 33 %,\n // soit 16,9 kWh. Le 17,5 precedent etait une valeur de plaque.\n // NB : sous 33 % un point ne vaut plus que 0,097 kWh. Cette constante ne sert\n // ici qu'a des ecarts SOC -> cible, tous deux au-dessus du genou. Si un calcul\n // devait un jour traverser le genou, il faut la COURBE (src/energy-balance/\n // BALANCE.js) et non cette constante.\n // 16,9 kWh mesures sur SEPT modules (§41), soit 2,414 kWh par module. Le parc\n // ayant change deux fois en une semaine, le nombre de modules se LIT au lieu\n // d'etre code : `input_number.evcs_balance_modules_en_service`, le meme helper\n // que le bilan energetique — les deux decrivent forcement le meme parc.\n // Absent ou illisible => 7, donc aucun changement tant que personne ne l'ecrit.\n batteryUsableCapacityKwh: 2.414 * (() => {\n const n = Number(input.modules_en_service);\n return Number.isFinite(n) && n >= 1 && n <= 16 ? n : 7;\n })(),\n nominalAcVoltageV: 230,\n evcsDedicatedMaxW: 4900,\n systemReserveW: 300,\n\n vebusDcVoltageSoftFloorV: 49.0,\n vebusDcVoltageHardFloorV: 48.6,\n\n departurePriorityWindowMinutes: 240,\n sampleSeconds: 30,\n\n cloudDebtRecoveryThresholdKwh: 0.05,\n cloudDebtMeaningfulThresholdKwh: 0.01,\n};\n\n// =====================================================\n// PARSED SNAPSHOT\n// =====================================================\nconst parsed = {\n soc: clamp(num(input.soc_percent, 0), 0, 100),\n batteryCurrentA: num(input.battery_current_a, 0),\n\n pvPowerW: Math.max(0, num(input.pv_power_w, 0)),\n\n // MODE DE FONCTIONNEMENT DES CHARGEURS SOLAIRES (03/09/2026)\n // Chaque tracker declare lui-meme s'il est a son point de puissance maximale\n // ('mppt_active' : il donne tout ce qu'il a) ou s'il se retient\n // ('voltage_current_limited', 'off' : il y a de la ressource REFUSEE).\n // Lectures inexploitables (integration muette) => listes vides => les gardes\n // aval retombent sur le comportement anterieur. On ne devine pas un etat.\n ...(() => {\n const modes = String(input.mppt_operation_modes || '')\n .split(',')\n .map(s => s.trim().toLowerCase())\n .filter(s => s !== '' && s !== 'unavailable' && s !== 'unknown');\n const atMaxPower = modes.filter(s => s === 'mppt_active').length;\n // Un chargeur qui SE RETIENT (`voltage_current_limited`) prouve qu'il reste\n // de la ressource refusee. Un chargeur `off` n'a rien a donner : la nuit,\n // tous le sont. `mpptHoldingBackCount` confond les deux, ce qui est sans\n // consequence pour la garde de provocation solaire (§37, demarrage de jour\n // seulement) mais ferait descendre la consigne reseau au crepuscule si on\n // s'en servait ici — un oscillateur de plus. On compte donc separement ce\n // qui se declare BRIDE, et tout libelle inconnu retombe du cote prudent\n // (pas de ressource refusee, donc comportement anterieur).\n const limited = modes.filter(s => s.includes('limited')).length;\n return {\n mpptReadableCount: modes.length,\n mpptAtMaxPowerCount: atMaxPower,\n mpptHoldingBackCount: modes.length - atMaxPower,\n mpptLimitedCount: limited,\n };\n })(),\n pvPowerAvg10mW: Math.max(0, num(input.pv_power_10m_avg_w, num(input.pv_power_w, 0))),\n pvTrendW: num(input.pv_trend_w, 0),\n\n houseAcPowerW: Math.max(0, num(input.house_ac_power_w, 0)),\n houseAcPowerPrevW: Math.max(0, num(input.house_ac_power_prev_w, num(input.house_ac_power_w, 0))),\n gridPowerW: num(input.grid_power_w, 0),\n\n gridIsOn: low(input.grid_state || 'off') === 'on',\n acInAvailable: num(input.victron_acin1_available ?? input.ac_in1_available, 0) === 1,\n\n // Consigne de puissance réseau de l'ESS, lue telle qu'elle est appliquée.\n // C'est ELLE qui décide si un contacteur fermé sert à quelque chose : au-dessus\n // du SOC minimal, l'ESS en autoconsommation ne prélève que cette puissance et\n // laisse la batterie porter le reste. Nuit du 01/09 : contacteur fermé,\n // consigne 50 W, batterie à -803 W pour 761 W de maison.\n gridSetpointW: num(input.grid_setpoint_w, NaN),\n gridAvailable:\n (low(input.grid_state || 'off') === 'on') ||\n (num(input.victron_acin1_available ?? input.ac_in1_available, 0) === 1),\n\n // FENETRE D'ETABLISSEMENT (31/08/2026) — age, en secondes, de la derniere\n // transition du reseau. On retient la plus RECENTE des deux sources : la\n // presence physique AC-IN (celle qui declenche reellement le transitoire) et\n // le contacteur (qui peut bouger sans qu'AC-IN suive, disjoncteur ouvert).\n // Horodatage absent ou nul => age tres grand => aucune fenetre, comportement\n // historique. On ne devine jamais une transition qu'on n'a pas observee.\n gridTransitionAgeSec: (() => {\n const ts = Math.max(\n num(input.acin1_last_changed_ts, 0),\n num(input.grid_switch_last_changed_ts, 0)\n );\n if (!(ts > 0)) return Number.POSITIVE_INFINITY;\n return Math.max(0, (nowMs / 1000) - ts);\n })(),\n\n todayRemainingKwh: Math.max(0, num(input.today_remaining_kwh, 0)),\n tomorrowKwh: Math.max(0, num(input.tomorrow_kwh, 0)),\n\n evcsDeviceConnected: low(input.evcs_device_connected || 'off') === 'on',\n evcsVehicleConnected: low(input.evcs_vehicle_connected || 'off') === 'on',\n evcsStatusRaw: cleanText(input.evcs_status_raw),\n evcsModeRaw: [\n input.evcs_mode_sensor,\n input.evcs_mode_fallback,\n input.evcs_mode\n ]\n .map(v => cleanText(v))\n .find(v => v) || 'unknown',\n\n evcsSetCurrentA: num(input.evcs_set_current_a, NaN),\n evcsCommandCurrentA: num(input.evcs_command_current_a, NaN),\n\n // Mesure réelle côté borne\n evcsCurrentA: Math.max(0, num(input.evcs_current_a, 0)),\n evcsCurrentRealA: Math.max(0, num(input.evcs_current_a, 0)),\n\n evcsAcPowerW: Math.max(0, num(input.evcs_ac_power_w, 0)),\n evcsChargingTimeSec: parseChargingTimeToSec(input.evcs_charging_time),\n // Energie deja livree par la session EN COURS (kWh). Le capteur de la borne\n // s'appelle \"last_session_energy\" mais il suit la session courante et repart\n // de zero a chaque nouvelle connexion (verifie le 07/09/2026 : 0 -> 0,1 -> 0,2\n // ... pendant la charge). Sert a juger la credibilite d'un statut \"charged\".\n evcsSessionEnergyKwh: Math.max(0, num(input.evcs_session_energy_kwh, 0)),\n evcsChargingSwitchOn: low(input.evcs_charging_switch || 'off') === 'on',\n evcsAutoStartSwitchOn: low(input.evcs_auto_start_switch || 'off') === 'on',\n\n controllerEnabled: low(input.controller_enabled || 'off') === 'on',\n notificationsEnabled: low(input.notifications_enabled || 'off') === 'on',\n hardStopEnabledLegacy: low(input.hard_stop_enabled || 'off') === 'on',\n chargePermissionNow: low(input.charge_permission_now || 'off') === 'on',\n controlLatch: low(input.control_latch || 'off') === 'on',\n departurePriorityEnabled: low(input.departure_priority_enabled || 'off') === 'on',\n forecastModeEnabled: low(input.forecast_mode_enabled || 'off') === 'on',\n\n evcsPriorityManualOverride: low(input.evcs_priority_manual_override || 'off') === 'on',\n evcsPriorityManualMode: cleanText(input.evcs_priority_manual_mode || 'normal', 'normal').toLowerCase(),\n evcsPriorityManualReason: cleanText(input.evcs_priority_manual_reason),\n\n vebusOverload: low(input.vebus_overload || 'off') === 'on',\n vebusL1Overload: low(input.vebus_l1_overload || 'off') === 'on',\n vebusLowBattery: low(input.vebus_low_battery || 'off') === 'on',\n vebusL1LowBattery: low(input.vebus_l1_low_battery || 'off') === 'on',\n\n vebusAcOutPowerW: Math.max(0, num(input.vebus_ac_out_l1_power_w, 0)),\n vebusAcOutCurrentA: Math.max(0, num(input.vebus_ac_out_l1_current_a, 0)),\n vebusAcOutVoltageV: num(input.vebus_ac_out_l1_voltage_v, CFG.nominalAcVoltageV),\n\n vebusDcVoltageV: num(input.vebus_dc_voltage_v, NaN),\n vebusDcCurrentA: num(input.vebus_dc_current_a, NaN),\n vebusDcPowerW: num(input.vebus_dc_power_w, NaN),\n\n vebusState: num(input.vebus_state, NaN),\n vebusMainState: num(input.vebus_main_state, NaN),\n};\n\nparsed.evcsModeIsAuto = low(parsed.evcsModeRaw).includes('auto');\n\n// =====================================================\n// PARAMETERS\n// =====================================================\nconst params = {\n userStrategyRaw: input.victron_evcs_strategy || 'auto_solar',\n\n targetCurrentAutoA: clamp(num(input.target_current_auto_a, 6), 0, 32),\n pvStartMinW: Math.max(0, num(input.pv_start_min_w, 1800)),\n pvHoldMinW: Math.max(0, num(input.pv_hold_min_w, 1200)),\n houseAcHeadroomW: Math.max(0, num(input.house_ac_headroom_w, 1200)),\n\n batteryDischargeSoftA: num(input.battery_discharge_soft_a, -5),\n batteryDischargeHardA: num(input.battery_discharge_hard_a, -15),\n batteryReserveUpA: Math.max(0, num(input.battery_reserve_up_a, 8)),\n batteryNeutralBandA: Math.max(0, num(input.battery_neutral_band_a, 3)),\n\n socStartMin: clamp(num(input.soc_start_min, 60), 0, 100),\n socStopMin: clamp(num(input.soc_stop_min, 35), 0, 100),\n\n currentMinA: clamp(num(input.current_min_a, 6), 6, 32),\n currentMaxAutoA: clamp(\n num(input.current_max_auto_a, 16),\n clamp(num(input.current_min_a, 6), 6, 32),\n 32\n ),\n gridCurrentMaxA: clamp(num(input.grid_current_max_a, 20), 6, 32),\n currentStepUpA: clamp(num(input.current_step_up_a, 1), 1, 5),\n currentStepDownA: clamp(num(input.current_step_down_a, 2), 1, 8),\n\n currentChangeCooldownSeconds: Math.max(5, num(input.current_change_cooldown_seconds, 60)),\n minRunMinutes: Math.max(0, num(input.min_run_minutes, 3)),\n minStopMinutes: Math.max(0, num(input.min_stop_minutes, 10)),\n\n requiredEnergyKwh: Math.max(0, num(input.required_energy_kwh, 0)),\n socComfortTarget: clamp(num(input.soc_comfort_target, 85), 0, 100),\n endOfDaySocGuard: clamp(num(input.end_of_day_soc_guard, 85), 0, 100),\n baseLoadRemainingKwh: Math.max(0, num(input.base_load_remaining_kwh, 0)),\n flexibleSafetyMarginKwh: Math.max(0, num(input.flexible_safety_margin_kwh, 0)),\n endOfDaySocTarget: clamp(num(input.end_of_day_soc_target, 85), 0, 100),\n\n acLoadsMaxSafeW: Math.max(0, num(input.ac_loads_max_safe_w, 8500)),\n batteryFullSoc: clamp(num(input.battery_full_soc, 90), 0, 100),\n batteryFullForecastMinKwh: Math.max(0, num(input.battery_full_forecast_min_kwh, 8)),\n forecastCommitSocFloor: clamp(num(input.forecast_commit_soc_floor, 35), 0, 100),\n forecastCommitMinKwh: Math.max(0, num(input.forecast_commit_min_kwh, 25)),\n\n cloudDebtPrevKwh: Math.max(0, num(input.cloud_debt_kwh, 0)),\n cloudDebtMaxKwh: Math.max(0.05, num(input.cloud_debt_max_kwh, 1.2)),\n cloudToleranceMinutes: Math.max(1, num(input.cloud_tolerance_minutes, 20)),\n\n // P9 (09/08/2026) : deux véhicules alternent sur la borne.\n // Le sélecteur input_select.victron_evcs_vehicle choisit l'heure de départ\n // effective : VW = victron_evcs_departure_time (~08:50),\n // JEEP = victron_evcs_departure_time_jeep (~06:30).\n selectedVehicle: cleanText(input.evcs_vehicle, 'VW'),\n departureTimeMin:\n low(input.evcs_vehicle || 'vw') === 'jeep'\n ? parseTimeToMinutes(\n input.departure_time_jeep,\n parseTimeToMinutes(input.departure_time, null)\n )\n : parseTimeToMinutes(input.departure_time, null),\n allowGridDepartureUrgent: low(input.allow_grid_departure_urgent || 'off') === 'on',\n dayStartTimeMin: parseTimeToMinutes(input.day_start_time, 7 * 60 + 30),\n dayStopTimeMin: parseTimeToMinutes(input.day_stop_time, 20 * 60 + 30),\n\n hcNightStartMin: parseTimeToMinutes(input.hc_night_start_time, 23 * 60),\n hcNightStopMin: parseTimeToMinutes(input.hc_night_stop_time, 6 * 60),\n morningStartMin: parseTimeToMinutes(\n input.morning_start_time,\n parseTimeToMinutes(input.day_start_time, 7 * 60 + 30)\n ),\n morningStopMin: parseTimeToMinutes(input.morning_stop_time, 11 * 60),\n hcMiddayStartMin: parseTimeToMinutes(input.hc_midday_start_time, 12 * 60 + 21),\n hcMiddayStopMin: parseTimeToMinutes(input.hc_midday_stop_time, 14 * 60 + 21),\n eveningStartMin: parseTimeToMinutes(input.evening_start_time, 17 * 60),\n eveningStopMin: parseTimeToMinutes(\n input.evening_stop_time,\n parseTimeToMinutes(input.day_stop_time, 20 * 60 + 30)\n ),\n\n allowGridHcNight: low(input.allow_grid_hc_night || 'off') === 'on',\n allowGridHcMidday: low(input.allow_grid_hc_midday || 'off') === 'on',\n\n // Advisor IA — premier câblage réel (09/08/2026, HANDOFF §20) :\n // cible SOC matin recommandée, appliquée UNIQUEMENT si le toggle est ON.\n // Garde-fous consommés dans WINDOWS_SOURCEV2 (statut ok + fraîcheur + bornes).\n advisorApplyNightTarget: low(input.advisor_apply_night_target || 'off') === 'on',\n advisorNightTargetSocPct: num(input.advisor_night_target_soc, NaN),\n advisorStatusOk: cleanText(input.advisor_status).toLowerCase() === 'ok',\n advisorLastRunMs: parseAdvisorRunToMs(cleanText(input.advisor_last_run)),\n\n // BILAN ENERGETIQUE (03/09/2026). Meme format d'horodatage que l'advisor\n // (\"DD/MM HH:mm\"), d'ou la reutilisation du parseur.\n balanceRequiredSocPct: num(input.balance_required_soc, NaN),\n balanceEnergyToCoverKwh: num(input.balance_energy_to_cover_kwh, NaN),\n balanceStatusOk: cleanText(input.balance_status).toLowerCase() === 'ok',\n balanceLastRunMs: parseAdvisorRunToMs(cleanText(input.balance_last_run)),\n\n // Duree de la fenetre d'etablissement. Valeur mesuree le 31/08/2026 : le\n // transitoire de fermeture dure ~150 s (import 1985 -> 25 W et 2600 -> 52 W,\n // deux campagnes), on prend 180 s de marge. Reglable sans redeploiement via\n // input_number.evcs_grid_settle_seconds ; absent => 180.\n gridSettleSeconds: clamp(num(input.grid_settle_seconds, 180), 0, 900),\n\n // Consigne réseau au repos. 50 W est le défaut Victron (légèrement positif\n // pour ne jamais injecter), pas une valeur choisie ici.\n // CONSIGNE DE REPOS : 200 W et non plus 50 (04/09/2026).\n // 50 W etait le defaut Victron. Mesure sur la nuit du 03-04/09, 12 074\n // echantillons du point de raccordement : 17 % sont NEGATIFS, mediane -18 W,\n // excursions jusqu'a -356 W, episodes de 35 s au plus. Ce n'est pas de\n // l'injection — la batterie se dechargeait a 744 W au meme moment — c'est le\n // regulateur qui chasse autour d'une cible trop proche de zero. A 200 W le\n // point de fonctionnement reste positif sur l'essentiel des excursions.\n // ⚠️ Ne supprime pas les pointes les plus fortes : une excursion de -356 W\n // passerait encore sous zero. Reduit leur nombre, ne les annule pas.\n // CONSIGNE DE REPOS : 50 -> 200 (04/09) -> 700 (06/09).\n //\n // Elle ne s'applique que contacteur FERME sans session reseau EVCS — donc\n // apres une coupure sur SOC bas, ou apres une fermeture par la regle de\n // protection du parc. Contacteur ouvert, elle n'a aucun effet.\n //\n // A 200 W, une plaque chauffante qui cycle fait passer le point de\n // fonctionnement sous zero : mesure du 06/09 sur la fenetre 12:07-12:22,\n // 9 % des echantillons negatifs, minimum -477 W, mediane des negatifs\n // -146 W. Le regulateur ne rattrape pas assez vite un delestage brutal de\n // ~1 kW. A 700 W toute la courbe monte de 500 W : minimum +23 W, plus aucune\n // excursion negative sur cette fenetre.\n //\n // Le surcout est faible et va dans le bon sens : les DEUX seules raisons de\n // fermer le contacteur sans session EVCS sont « la batterie est a son\n // plancher » et « la maison demande plus que le parc ne sait donner ». Dans\n // les deux cas on VEUT que le reseau contribue plus que 200 W.\n //\n // ⚠️ Ne corrige PAS les gros a-coups. Le 06/09 a 13:41:40, le debranchement\n // du vehicule a supprime 2,2 kW d'un coup alors que la batterie, a 93 % de\n // SOC, n'absorbait rien et que le MPPT produisait 4 kW : -2 819 W pendant\n // plus de deux minutes, le temps que le systeme bride la production. Aucune\n // consigne n'absorbe cela. Ce qui l'evite est la correction du meme jour sur\n // la regle de protection (elle porte desormais sur `maison - PV`) : avec une\n // demande sur le parc de 741 W, le contacteur n'aurait pas ete ferme, et\n // sans reseau il n'y a rien ou injecter.\n gridSetpointIdleW: clamp(num(input.grid_setpoint_idle_w, 700), 0, 1500),\n\n probeEnabled: low(input.probe_enabled || 'off') === 'on',\n probeMinutes: Math.max(1, num(input.probe_minutes, 3)),\n probeRetryMinutes: Math.max(5, num(input.probe_retry_minutes, 45)),\n probeCurrentA: clamp(\n num(input.probe_current_a, clamp(num(input.current_min_a, 10), 6, 32)),\n clamp(num(input.current_min_a, 10), 6, 32),\n clamp(num(input.current_max_auto_a, 16), clamp(num(input.current_min_a, 10), 6, 32), 32)\n ),\n\n gridBatterySoftA: num(input.grid_battery_soft_a, -3),\n gridBatteryHardA: num(input.grid_battery_hard_a, -6),\n\n morningProbePvAvgMinW: Math.max(0, num(input.morning_probe_pv_avg_min_w, 1500)),\n morningProbePvTrendMinW: num(input.morning_probe_pv_trend_min_w, 0),\n middayProbePvAvgMinW: Math.max(0, num(input.midday_probe_pv_avg_min_w, 1200)),\n\n morningSocMin: clamp(num(input.morning_soc_min, 35), 0, 100),\n middaySocMin: clamp(num(input.midday_soc_min, 75), 0, 100),\n eveningSocStartMin: clamp(num(input.evening_soc_start_min, 85), 0, 100),\n eveningSocStopMin: clamp(num(input.evening_soc_stop_min, 80), 0, 100),\n\n morningBatteryMaxDischargeA: num(input.morning_battery_max_discharge_a, -20),\n middayBatteryMaxDischargeA: num(input.midday_battery_max_discharge_a, -40),\n eveningBatteryMaxDischargeA: num(input.evening_battery_max_discharge_a, -30),\n\n // =====================================================\n // EVCS NIGHT ENGINE — NEW PARAMETERS\n // =====================================================\n evcsNightBatteryHardFloorPct: clamp(\n num(input.evcs_night_battery_hard_floor_pct, 22),\n 0,\n 100\n ),\n\n evcsNightStrongForecastKwh: Math.max(\n 0,\n num(input.evcs_night_strong_forecast_kwh, 18)\n ),\n\n evcsNightMediumForecastKwh: Math.max(\n 0,\n num(input.evcs_night_medium_forecast_kwh, 10)\n ),\n\n evcsNightTargetStrongForecastPct: clamp(\n num(input.evcs_night_target_strong_forecast_pct, 35),\n 0,\n 100\n ),\n\n evcsNightTargetMediumForecastPct: clamp(\n num(input.evcs_night_target_medium_forecast_pct, 55),\n 0,\n 100\n ),\n\n evcsNightTargetWeakForecastPct: clamp(\n num(input.evcs_night_target_weak_forecast_pct, 85),\n 0,\n 100\n ),\n\n evcsNightBatteryRecoveryPowerKw: Math.max(\n 0.1,\n num(input.evcs_night_battery_recovery_power_kw, 2.5)\n ),\n\n evcsNightDepartureSafetyMin: Math.max(\n 0,\n num(input.evcs_night_departure_safety_min, 30)\n ),\n};\n\n// =====================================================\n// HISTORY / PERSISTED HELPERS\n// =====================================================\nconst nightSessionStartSocRaw = num(\n input.evcs_night_session_start_soc ?? input.night_session_start_soc,\n NaN\n);\n\nconst nightSessionStartAtRaw = cleanText(\n input.evcs_night_session_start_at ?? input.night_session_start_at\n);\n\n// =====================================================\n// VEHICLE DEMAND FILTER HISTORY RAW INPUTS\n// =====================================================\nconst evcsNoDemandSinceAtRaw = cleanText(input.evcs_no_demand_since_at);\nconst evcsNoDemandFilterEvalAtRaw = cleanText(input.evcs_no_demand_filter_eval_at);\n\nconst history = {\n lastBlockReason: cleanText(input.last_block_reason, 'none') || 'none',\n blockedUntilAt: cleanText(input.blocked_until),\n probeStartedAt: cleanText(input.probe_started_at),\n lastStartAt: cleanText(input.last_start_at),\n lastStopAt: cleanText(input.last_stop_at),\n lastCurrentChangeAt: cleanText(input.last_current_change_at),\n lastSignature: cleanText(input.last_signature),\n cloudDebtStartedAt: cleanText(input.cloud_debt_started_at),\n evcsPriorityManualUntilAt: cleanText(input.evcs_priority_manual_until),\n\n blockedUntilMs: parseParisStampToMs(cleanText(input.blocked_until)),\n probeStartedMs: parseParisStampToMs(cleanText(input.probe_started_at)),\n lastStartMs: parseParisStampToMs(cleanText(input.last_start_at)),\n lastStopMs: parseParisStampToMs(cleanText(input.last_stop_at)),\n lastCurrentChangeMs: parseParisStampToMs(cleanText(input.last_current_change_at)),\n cloudDebtStartedMsPrev: parseParisStampToMs(cleanText(input.cloud_debt_started_at)),\n\n // DEPASSEMENT SOUPLE BATTERIE (01/09/2026) : horodatage du debut du\n // depassement en cours, ecrit par HA_SERVICE_CALLS_OUTPUT. Vide/illisible\n // => null => aucun depassement en cours, comportement de repli sur.\n nightGridSessionCommittedPrev:\n (input.night_grid_session_committed_prev ?? 'off').toString().trim().toLowerCase() === 'on',\n batterySoftBreachAt: cleanText(input.battery_soft_breach_at),\n batterySoftBreachMsPrev: parseParisStampToMs(cleanText(input.battery_soft_breach_at)),\n evcsPriorityManualUntilMs: parseParisStampToMs(cleanText(input.evcs_priority_manual_until)),\n\n // =====================================================\n // EVCS NIGHT SESSION MEMORY\n // =====================================================\n nightSessionStartSocPct: Number.isFinite(nightSessionStartSocRaw)\n ? clamp(nightSessionStartSocRaw, 0, 100)\n : null,\n\n nightSessionStartAt: nightSessionStartAtRaw || '',\n nightSessionStartMs: parseParisStampToMs(nightSessionStartAtRaw),\n\n // =====================================================\n // VEHICLE DEMAND FILTER PERSISTENCE\n // =====================================================\n evcsDeliveryRatioEma: num(input.evcs_delivery_ratio_ema, NaN),\n evcsDeliveryNoiseEma: num(input.evcs_delivery_noise_ema, NaN),\n evcsNoDemandScoreEma: num(input.evcs_no_demand_score_ema, NaN),\n evcsNoDemandSemanticActive: low(input.evcs_no_demand_semantic_active || 'off') === 'on',\n\n evcsNoDemandSinceAt: evcsNoDemandSinceAtRaw || '',\n evcsNoDemandSinceMs: parseParisStampToMs(evcsNoDemandSinceAtRaw),\n\n evcsNoDemandFilterEvalAt: evcsNoDemandFilterEvalAtRaw || '',\n evcsNoDemandFilterEvalMs: parseParisStampToMs(evcsNoDemandFilterEvalAtRaw),\n};\n\n// =====================================================\n// MISE A L'ECHELLE DU PARC (12/09/2026)\n// =====================================================\n// Les bandes ci-dessous sont en AMPERES ABSOLUS, et elles decrivent un parc\n// de 4 modules -- celui sur lequel elles sont aujourd'hui en vigueur et\n// observees justes (l'arret dur du 11/09 a mordu au bon endroit, 87 A pour\n// une limite de 70). Avec quatre US5000 en plus, le parc triple : garder ces\n// ampere-la briderait le nouveau parc au niveau de l'ancien.\n//\n// On les met donc a l'echelle du parc DECLARE — le meme helper que la\n// capacite utile et que le bilan energetique, exprime en equivalents\n// US2000C (un US5000 en vaut DEUX). Une seule valeur a tenir a jour, et les\n// trois consommateurs restent forcement d'accord entre eux.\n//\n// ⚠️ On ne met PAS a l'echelle sur la limite BMS lue en direct : elle\n// s'effondre quand une cellule monte en tension (04/09 : plafond de charge\n// tombe de 150 a 20 A en cinq secondes). Une regle de confort ne doit pas\n// suivre un signal aussi nerveux. En revanche le BMS PLAFONNE : on ne\n// s'autorise jamais plus que ce que le parc declare accepter a l'instant.\n//\n// Parc absent ou illisible => echelle 1 et plafond inactif, donc comportement\n// d'aujourd'hui strictement inchange.\nconst parkScale = (() => {\n const n = Number(input.modules_en_service);\n return Number.isFinite(n) && n >= 1 && n <= 32 ? n / 4 : 1;\n})();\nconst bmsDischargeCapA = (() => {\n const n = Number(input.bms_max_discharge_current_a);\n return Number.isFinite(n) && n > 0 ? n : Infinity;\n})();\nconst bmsChargeCapA = (() => {\n const n = Number(input.bms_max_charge_current_a);\n return Number.isFinite(n) && n > 0 ? n : Infinity;\n})();\n// Decharge : valeurs NEGATIVES, donc le plafond est un `Math.max`.\nconst scaleDischargeA = v => Math.max(-bmsDischargeCapA, v * parkScale);\nconst scaleChargeA = v => Math.min(bmsChargeCapA, Math.max(0, v) * parkScale);\n\n// =====================================================\n// BATTERY TUNING\n// =====================================================\nconst batteryTune = {\n global: {\n houseSpikeGraceMinutes: Math.max(0, num(input.house_spike_grace_minutes, 10)),\n solarPotentialGraceMinutes: Math.max(0, num(input.solar_potential_grace_minutes, 12)),\n stepUpCooldownSeconds: Math.max(5, num(input.step_up_cooldown_seconds, params.currentChangeCooldownSeconds)),\n stepDownCooldownSeconds: Math.max(5, num(input.step_down_cooldown_seconds, params.currentChangeCooldownSeconds)),\n forceModeAutoRevertMinutes: Math.max(0, num(input.force_mode_auto_revert_minutes, 120)),\n overloadStepDownA: Math.max(1, num(input.overload_step_down_a, 2)),\n overloadHoldSeconds: Math.max(5, num(input.overload_hold_seconds, 30)),\n overloadStopAfterSeconds: Math.max(10, num(input.overload_stop_after_seconds, 120)),\n },\n\n bands: {\n gt90: {\n dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_gt90_a, -50)),\n dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_gt90_a, -100)),\n chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_gt90_a, 5)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_gt90_min, 12)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_gt90_sec, 20)),\n recoveryMin: Math.max(0, num(input.batt_recovery_gt90_min, 6)),\n },\n\n '80_90': {\n dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_80_90_a, -40)),\n dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_80_90_a, -80)),\n chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_80_90_a, 10)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_80_90_min, 10)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_80_90_sec, 20)),\n recoveryMin: Math.max(0, num(input.batt_recovery_80_90_min, 6)),\n },\n\n '60_80': {\n dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_60_80_a, -20)),\n dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_60_80_a, -50)),\n chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_60_80_a, 40)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_60_80_min, 6)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_60_80_sec, 15)),\n recoveryMin: Math.max(0, num(input.batt_recovery_60_80_min, 8)),\n },\n\n '40_60': {\n dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_40_60_a, -12)),\n dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_40_60_a, -30)),\n chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_40_60_a, 70)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_40_60_min, 4)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_40_60_sec, 10)),\n recoveryMin: Math.max(0, num(input.batt_recovery_40_60_min, 10)),\n },\n\n '25_40': {\n dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_25_40_a, -5)),\n dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_25_40_a, -15)),\n chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_25_40_a, 110)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_25_40_min, 2)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_25_40_sec, 5)),\n recoveryMin: Math.max(0, num(input.batt_recovery_25_40_min, 12)),\n },\n\n lt25: {\n dischargeSoftA: scaleDischargeA(num(input.batt_discharge_soft_lt25_a, -3)),\n dischargeHardA: scaleDischargeA(num(input.batt_discharge_hard_lt25_a, -8)),\n chargeReserveA: scaleChargeA(num(input.batt_charge_reserve_lt25_a, 150)),\n softToleranceMin: Math.max(0, num(input.batt_soft_tol_lt25_min, 1)),\n hardToleranceSec: Math.max(0, num(input.batt_hard_tol_lt25_sec, 2)),\n recoveryMin: Math.max(0, num(input.batt_recovery_lt25_min, 15)),\n },\n },\n};\n\n// =====================================================\n// OPTIONAL DEBUG / SUMMARY\n// =====================================================\nconst evcsNightConfig = {\n batteryHardFloorPct: params.evcsNightBatteryHardFloorPct,\n strongForecastKwh: params.evcsNightStrongForecastKwh,\n mediumForecastKwh: params.evcsNightMediumForecastKwh,\n targetStrongForecastPct: params.evcsNightTargetStrongForecastPct,\n targetMediumForecastPct: params.evcsNightTargetMediumForecastPct,\n targetWeakForecastPct: params.evcsNightTargetWeakForecastPct,\n batteryRecoveryPowerKw: params.evcsNightBatteryRecoveryPowerKw,\n departureSafetyMin: params.evcsNightDepartureSafetyMin,\n sessionStartSocPct: history.nightSessionStartSocPct,\n sessionStartAt: history.nightSessionStartAt || null,\n};\n\nconst vehicleDemandHistoryDebug = {\n evcsDeliveryRatioEma: finiteOrNull(history.evcsDeliveryRatioEma),\n evcsDeliveryNoiseEma: finiteOrNull(history.evcsDeliveryNoiseEma),\n evcsNoDemandScoreEma: finiteOrNull(history.evcsNoDemandScoreEma),\n evcsNoDemandSemanticActive: history.evcsNoDemandSemanticActive,\n evcsNoDemandSinceAt: history.evcsNoDemandSinceAt || null,\n evcsNoDemandSinceMs: finiteOrNull(history.evcsNoDemandSinceMs),\n evcsNoDemandFilterEvalAt: history.evcsNoDemandFilterEvalAt || null,\n evcsNoDemandFilterEvalMs: finiteOrNull(history.evcsNoDemandFilterEvalMs),\n};\n\n// =====================================================\n// OUTPUT\n// =====================================================\nreturn [{\n json: {\n raw,\n input,\n nowMs,\n now,\n cfg: CFG,\n parsed,\n params,\n history,\n batteryTune,\n evcsNightConfig,\n vehicleDemandHistoryDebug,\n }\n}];\n" }, "type": "n8n-nodes-base.code", "typeVersion": 2, @@ -142,7 +142,7 @@ "parameters": [ { "name": "template", - "value": "{{ {\n \"soc_percent\": states(\"sensor.victron_battery_soc\"),\n \"battery_current_a\": states(\"sensor.victron_battery_current\"),\n\n \"pv_power_w\": states(\"sensor.victron_pv_power_system\"),\n \"pv_power_10m_avg_w\": states(\"sensor.victron_pv_power_10m_avg\"),\n \"pv_trend_w\": states(\"sensor.victron_pv_power_trend_w\"),\n\n \"mppt_operation_modes\": states.sensor\n | selectattr('entity_id','search','mppt')\n | selectattr('entity_id','search','operation_mode')\n | map(attribute='state') | join(','),\n\n \"house_ac_power_w\": states(\"sensor.victron_consumption_power_l1\"),\n \"house_ac_power_prev_w\": states(\"sensor.victron_consumption_power_l1\"),\n\n \"grid_power_w\": states(\"sensor.victron_grid_power_l1\"),\n \"grid_state\": states(\"switch.edf_general_ok_switch\"),\n \"victron_acin1_available\": states(\"sensor.victron_ac_in1_available\"),\n\n \n \"acin1_last_changed_ts\": as_timestamp(states.sensor.victron_ac_in1_available.last_changed, 0) if states.sensor.victron_ac_in1_available is not none else 0,\n \"grid_switch_last_changed_ts\": as_timestamp(states.switch.edf_general_ok_switch.last_changed, 0) if states.switch.edf_general_ok_switch is not none else 0,\n \"grid_settle_seconds\": states(\"input_number.evcs_grid_settle_seconds\"),\n \"grid_setpoint_w\": states(\"number.gx_device_ac_power_setpoint\"),\n \"grid_setpoint_idle_w\": states(\"input_number.evcs_grid_setpoint_idle_w\"),\n\n \"today_remaining_kwh\": states(\"sensor.energy_production_today_remaining\"),\n \"tomorrow_kwh\": states(\"sensor.energy_production_tomorrow\"),\n\n \"evcs_device_connected\": states(\"binary_sensor.victron_evcs_device_connected\"),\n \"evcs_vehicle_connected\": states(\"binary_sensor.victron_evcs_vehicle_connected\"),\n \"evcs_status_raw\": states(\"sensor.victron_evcs_status_raw\"),\n \"evcs_mode_sensor\": states(\"sensor.victron_evcs_mode\"),\n \"evcs_mode_fallback\": states(\"input_text.sensor_victron_evcs_mode\"),\n \"evcs_set_current_a\": states(\"sensor.victron_evcs_set_current\"),\n \"evcs_command_current_a\": states(\"number.victron_evcs_set_current_command\"),\n \"evcs_current_a\": states(\"sensor.victron_evcs_current\"),\n \"evcs_ac_power_w\": states(\"sensor.victron_evcs_ac_power\"),\n \"evcs_charging_time\": states(\"sensor.victron_evcs_charging_time\"),\n \"evcs_session_energy_kwh\": states(\"sensor.evcs_hq2239dnt7p_last_session_energy\"),\n \"evcs_charging_switch\": states(\"switch.victron_evcs_charging\"),\n \"evcs_auto_start_switch\": states(\"switch.victron_evcs_auto_start\"),\n\n \"controller_enabled\": states(\"input_boolean.victron_evcs_surplus_auto_enabled\"),\n \"notifications_enabled\": states(\"input_boolean.victron_evcs_surplus_notifications\"),\n \"hard_stop_enabled\": states(\"input_boolean.victron_evcs_hard_stop_enabled\"),\n \"charge_permission_now\": states(\"input_boolean.victron_evcs_charge_permission_now\"),\n \"control_latch\": states(\"input_boolean.victron_evcs_control_latch\"),\n \"departure_priority_enabled\": states(\"input_boolean.victron_evcs_departure_priority_enabled\"),\n \"forecast_mode_enabled\": states(\"input_boolean.victron_evcs_forecast_mode_enabled\"),\n\n \"target_current_auto_a\": states(\"input_number.victron_evcs_target_current_auto\"),\n \"budget_remaining_kwh\": states(\"input_number.victron_evcs_budget_remaining_kwh\"),\n \"projected_end_soc_after_charge\": states(\"input_number.victron_evcs_projected_end_soc_after_charge\"),\n\n \"pv_start_min_w\": states(\"input_number.victron_evcs_pv_start_min_w\"),\n \"pv_hold_min_w\": states(\"input_number.victron_evcs_pv_hold_min_w\"),\n \"house_ac_headroom_w\": states(\"input_number.victron_evcs_house_ac_headroom_w\"),\n \"battery_discharge_soft_a\": states(\"input_number.victron_evcs_battery_discharge_soft_a\"),\n \"battery_discharge_hard_a\": states(\"input_number.victron_evcs_battery_discharge_hard_a\"),\n \"battery_reserve_up_a\": states(\"input_number.victron_evcs_battery_reserve_up_a\"),\n \"battery_neutral_band_a\": states(\"input_number.victron_evcs_battery_neutral_band_a\"),\n \"soc_start_min\": states(\"input_number.victron_evcs_soc_start_min\"),\n \"modules_en_service\": states(\"input_number.evcs_balance_modules_en_service\"),\n \"soc_stop_min\": states(\"input_number.victron_evcs_soc_stop_min\"),\n \"current_min_a\": states(\"input_number.victron_evcs_current_min_a\"),\n \"current_max_auto_a\": states(\"input_number.victron_evcs_current_max_auto_a\"),\n \"grid_current_max_a\": states(\"input_number.evcs_plafond_courant_edf_on\"),\n \"current_step_up_a\": states(\"input_number.victron_evcs_current_step_up_a\"),\n \"current_step_down_a\": states(\"input_number.victron_evcs_current_step_down_a\"),\n \"current_change_cooldown_seconds\": states(\"input_number.victron_evcs_current_change_cooldown_seconds\"),\n \"min_run_minutes\": states(\"input_number.victron_evcs_min_run_minutes\"),\n \"min_stop_minutes\": states(\"input_number.victron_evcs_min_stop_minutes\"),\n\n \"required_energy_kwh\": states(\"input_number.victron_evcs_required_energy_kwh\"),\n \"soc_comfort_target\": states(\"input_number.victron_evcs_soc_comfort_target\"),\n \"end_of_day_soc_guard\": states(\"input_number.victron_evcs_end_of_day_soc_guard\"),\n\n \"base_load_remaining_kwh\": states(\"input_number.victron_base_load_remaining_kwh\"),\n \"flexible_safety_margin_kwh\": states(\"input_number.victron_flexible_safety_margin_kwh\"),\n \"end_of_day_soc_target\": states(\"input_number.victron_end_of_day_soc_target\"),\n \"ac_loads_max_safe_w\": states(\"input_number.victron_ac_loads_max_safe_w\"),\n\n \"battery_full_soc\": states(\"input_number.victron_evcs_battery_full_soc\"),\n \"battery_full_forecast_min_kwh\": states(\"input_number.victron_evcs_battery_full_forecast_min_kwh\"),\n \"forecast_commit_soc_floor\": states(\"input_number.victron_evcs_forecast_commit_soc_floor\"),\n \"forecast_commit_min_kwh\": states(\"input_number.victron_evcs_forecast_commit_min_kwh\"),\n\n \"cloud_debt_kwh\": states(\"input_number.victron_evcs_cloud_debt_kwh\"),\n \"cloud_debt_max_kwh\": states(\"input_number.victron_evcs_cloud_debt_max_kwh\"),\n \"cloud_tolerance_minutes\": states(\"input_number.victron_evcs_cloud_tolerance_minutes\"),\n \"cloud_debt_started_at\": states(\"input_datetime.victron_evcs_cloud_debt_started_at\"),\n \"battery_soft_breach_at\": states(\"input_text.victron_evcs_battery_soft_breach_at\"),\n \"operating_mode_helper\": states(\"input_text.victron_evcs_operating_mode\"),\n\n \"departure_time\": states(\"input_datetime.victron_evcs_departure_time\"),\n \"departure_time_jeep\": states(\"input_datetime.victron_evcs_departure_time_jeep\"),\n \"evcs_vehicle\": states(\"input_select.victron_evcs_vehicle\"),\n \"allow_grid_departure_urgent\": states(\"input_boolean.victron_evcs_allow_grid_departure_urgent\"),\n \"last_start_at\": states(\"input_datetime.victron_evcs_last_start_at\"),\n \"last_stop_at\": states(\"input_datetime.victron_evcs_last_stop_at\"),\n \"last_current_change_at\": states(\"input_datetime.victron_evcs_last_current_change_at\"),\n\n \"day_start_time\": states(\"input_datetime.victron_flexible_day_start_time\"),\n \"day_stop_time\": states(\"input_datetime.victron_flexible_day_stop_time\"),\n\n \"vebus_overload\": states(\"binary_sensor.victron_ve_bus_overload\"),\n \"vebus_l1_overload\": states(\"binary_sensor.victron_ve_bus_l1_overload\"),\n \"vebus_low_battery\": states(\"binary_sensor.victron_ve_bus_low_battery\"),\n \"vebus_l1_low_battery\": states(\"binary_sensor.victron_ve_bus_l1_low_battery\"),\n\n \"vebus_ac_out_l1_power_w\": states(\"sensor.victron_ve_bus_ac_out_l1_power\"),\n \"vebus_ac_out_l1_current_a\": states(\"sensor.victron_ve_bus_ac_out_l1_current\"),\n \"vebus_ac_out_l1_voltage_v\": states(\"sensor.victron_ve_bus_ac_out_l1_voltage\"),\n\n \"vebus_dc_voltage_v\": states(\"sensor.victron_ve_bus_dc_voltage\"),\n \"vebus_dc_current_a\": states(\"sensor.victron_ve_bus_dc_current\"),\n \"vebus_dc_power_w\": states(\"sensor.victron_ve_bus_dc_power_system\"),\n\n \"vebus_state\": states(\"sensor.victron_ve_bus_state\"),\n \"vebus_main_state\": states(\"sensor.victron_ve_bus_main_state\"),\n\n \"last_signature\": states(\"input_text.victron_evcs_control_last_signature\"),\n\n \"hc_night_start_time\": states(\"input_datetime.victron_evcs_hc_night_start\"),\n \"hc_night_stop_time\": states(\"input_datetime.victron_evcs_hc_night_stop\"),\n \"morning_start_time\": states(\"input_datetime.victron_evcs_morning_start\"),\n \"morning_stop_time\": states(\"input_datetime.victron_evcs_morning_stop\"),\n \"hc_midday_start_time\": states(\"input_datetime.victron_evcs_hc_midday_start\"),\n \"hc_midday_stop_time\": states(\"input_datetime.victron_evcs_hc_midday_stop\"),\n \"evening_start_time\": states(\"input_datetime.victron_evcs_evening_start\"),\n \"evening_stop_time\": states(\"input_datetime.victron_evcs_evening_stop\"),\n\n \"allow_grid_hc_night\": states(\"input_boolean.victron_evcs_allow_grid_hc_night\"),\n \"night_takeover_prev\": states(\"input_boolean.victron_evcs_night_grid_takeover_needed\"),\n \"night_grid_session_committed_prev\": states(\"input_boolean.victron_evcs_night_grid_session_committed\"),\n \"prev_surplus_state\": states(\"input_text.victron_evcs_surplus_state\"),\n \"evcs_night_session_start_soc\": states(\"input_text.victron_evcs_night_session_start_soc\"),\n \"evcs_night_session_start_at\": states(\"input_text.victron_evcs_night_session_start_at\"),\n \"advisor_apply_night_target\": states(\"input_boolean.evcs_advisor_apply_night_target\"),\n \"advisor_night_target_soc\": states(\"input_number.evcs_advisor_night_target_soc\"),\n \"advisor_status\": states(\"input_text.evcs_advisor_status\"),\n \"advisor_last_run\": states(\"input_text.evcs_advisor_last_run\"),\n\n \"balance_required_soc\": states(\"input_number.evcs_balance_required_soc\"),\n \"balance_energy_to_cover_kwh\": states(\"input_number.evcs_balance_energy_to_cover_kwh\"),\n \"balance_status\": states(\"input_text.evcs_balance_status\"),\n \"balance_last_run\": states(\"input_text.evcs_balance_last_run\"),\n \"allow_grid_hc_midday\": states(\"input_boolean.victron_evcs_allow_grid_hc_midday\"),\n \"probe_enabled\": states(\"input_boolean.victron_evcs_probe_enabled\"),\n\n \"probe_minutes\": states(\"input_number.victron_evcs_probe_minutes\"),\n \"probe_retry_minutes\": states(\"input_number.victron_evcs_probe_retry_minutes\"),\n \"probe_current_a\": states(\"input_number.victron_evcs_probe_current_a\"),\n\n \"grid_battery_soft_a\": states(\"input_number.victron_evcs_grid_battery_soft_a\"),\n \"grid_battery_hard_a\": states(\"input_number.victron_evcs_grid_battery_hard_a\"),\n\n \"morning_probe_pv_avg_min_w\": states(\"input_number.victron_evcs_morning_probe_pv_avg_min_w\"),\n \"morning_probe_pv_trend_min_w\": states(\"input_number.victron_evcs_morning_probe_pv_trend_min_w\"),\n \"midday_probe_pv_avg_min_w\": states(\"input_number.victron_evcs_midday_probe_pv_avg_min_w\"),\n \"afternoon_probe_pv_avg_min_w\": states(\"input_number.victron_evcs_afternoon_probe_pv_avg_min_w\"),\n \"afternoon_probe_soc_min\": states(\"input_number.victron_evcs_afternoon_probe_soc_min\"),\n \"afternoon_battery_max_discharge_a\": states(\"input_number.victron_evcs_afternoon_battery_max_discharge_a\"),\n \"morning_soc_min\": states(\"input_number.victron_evcs_morning_soc_min\"),\n \"midday_soc_min\": states(\"input_number.victron_evcs_midday_soc_min\"),\n \"evening_soc_start_min\": states(\"input_number.victron_evcs_evening_soc_start_min\"),\n \"evening_soc_stop_min\": states(\"input_number.victron_evcs_evening_soc_stop_min\"),\n\n \"morning_battery_max_discharge_a\": states(\"input_number.victron_evcs_morning_battery_max_discharge_a\"),\n \"midday_battery_max_discharge_a\": states(\"input_number.victron_evcs_midday_battery_max_discharge_a\"),\n \"evening_battery_max_discharge_a\": states(\"input_number.victron_evcs_evening_battery_max_discharge_a\"),\n\n \"last_block_reason\": states(\"input_text.victron_evcs_last_block_reason\"),\n \"blocked_until\": states(\"input_datetime.victron_evcs_blocked_until\"),\n \"probe_started_at\": states(\"input_datetime.victron_evcs_probe_started_at\"),\n\n \"victron_evcs_strategy\": states(\"input_select.victron_evcs_strategy\"),\n \"evcs_priority_manual_override\": states(\"input_boolean.victron_evcs_priority_manual_override\"),\n \"evcs_priority_manual_mode\": states(\"input_select.victron_evcs_priority_manual_mode\"),\n \"evcs_priority_manual_reason\": states(\"input_text.victron_evcs_priority_manual_reason\"),\n \"evcs_priority_manual_until\": states(\"input_datetime.victron_evcs_priority_manual_until\"),\n\n \"house_spike_grace_minutes\": states(\"input_number.victron_evcs_house_spike_grace_minutes\"),\n \"solar_potential_grace_minutes\": states(\"input_number.victron_evcs_solar_potential_grace_minutes\"),\n \"step_up_cooldown_seconds\": states(\"input_number.victron_evcs_step_up_cooldown_seconds\"),\n \"step_down_cooldown_seconds\": states(\"input_number.victron_evcs_step_down_cooldown_seconds\"),\n \"force_mode_auto_revert_minutes\": states(\"input_number.victron_evcs_force_mode_auto_revert_minutes\"),\n\n \"overload_step_down_a\": states(\"input_number.victron_evcs_overload_step_down_a\"),\n \"overload_hold_seconds\": states(\"input_number.victron_evcs_overload_hold_seconds\"),\n \"overload_stop_after_seconds\": states(\"input_number.victron_evcs_overload_stop_after_seconds\"),\n\n \"batt_discharge_soft_gt90_a\": states(\"input_number.victron_evcs_batt_discharge_soft_gt90_a\"),\n \"batt_discharge_hard_gt90_a\": states(\"input_number.victron_evcs_batt_discharge_hard_gt90_a\"),\n \"batt_charge_reserve_gt90_a\": states(\"input_number.victron_evcs_batt_charge_reserve_gt90_a\"),\n \"batt_soft_tol_gt90_min\": states(\"input_number.victron_evcs_batt_soft_tol_gt90_min\"),\n \"batt_hard_tol_gt90_sec\": states(\"input_number.victron_evcs_batt_hard_tol_gt90_sec\"),\n \"batt_recovery_gt90_min\": states(\"input_number.victron_evcs_batt_recovery_gt90_min\"),\n\n \"batt_discharge_soft_80_90_a\": states(\"input_number.victron_evcs_batt_discharge_soft_80_90_a\"),\n \"batt_discharge_hard_80_90_a\": states(\"input_number.victron_evcs_batt_discharge_hard_80_90_a\"),\n \"batt_charge_reserve_80_90_a\": states(\"input_number.victron_evcs_batt_charge_reserve_80_90_a\"),\n \"batt_soft_tol_80_90_min\": states(\"input_number.victron_evcs_batt_soft_tol_80_90_min\"),\n \"batt_hard_tol_80_90_sec\": states(\"input_number.victron_evcs_batt_hard_tol_80_90_sec\"),\n \"batt_recovery_80_90_min\": states(\"input_number.victron_evcs_batt_recovery_80_90_min\"),\n\n \"batt_discharge_soft_60_80_a\": states(\"input_number.victron_evcs_batt_discharge_soft_60_80_a\"),\n \"batt_discharge_hard_60_80_a\": states(\"input_number.victron_evcs_batt_discharge_hard_60_80_a\"),\n \"batt_charge_reserve_60_80_a\": states(\"input_number.victron_evcs_batt_charge_reserve_60_80_a\"),\n \"batt_soft_tol_60_80_min\": states(\"input_number.victron_evcs_batt_soft_tol_60_80_min\"),\n \"batt_hard_tol_60_80_sec\": states(\"input_number.victron_evcs_batt_hard_tol_60_80_sec\"),\n \"batt_recovery_60_80_min\": states(\"input_number.victron_evcs_batt_recovery_60_80_min\"),\n\n \"batt_discharge_soft_40_60_a\": states(\"input_number.victron_evcs_batt_discharge_soft_40_60_a\"),\n \"batt_discharge_hard_40_60_a\": states(\"input_number.victron_evcs_batt_discharge_hard_40_60_a\"),\n \"batt_charge_reserve_40_60_a\": states(\"input_number.victron_evcs_batt_charge_reserve_40_60_a\"),\n \"batt_soft_tol_40_60_min\": states(\"input_number.victron_evcs_batt_soft_tol_40_60_min\"),\n \"batt_hard_tol_40_60_sec\": states(\"input_number.victron_evcs_batt_hard_tol_40_60_sec\"),\n \"batt_recovery_40_60_min\": states(\"input_number.victron_evcs_batt_recovery_40_60_min\"),\n\n \"batt_discharge_soft_25_40_a\": states(\"input_number.victron_evcs_batt_discharge_soft_25_40_a\"),\n \"batt_discharge_hard_25_40_a\": states(\"input_number.victron_evcs_batt_discharge_hard_25_40_a\"),\n \"batt_charge_reserve_25_40_a\": states(\"input_number.victron_evcs_batt_charge_reserve_25_40_a\"),\n \"batt_soft_tol_25_40_min\": states(\"input_number.victron_evcs_batt_soft_tol_25_40_min\"),\n \"batt_hard_tol_25_40_sec\": states(\"input_number.victron_evcs_batt_hard_tol_25_40_sec\"),\n \"batt_recovery_25_40_min\": states(\"input_number.victron_evcs_batt_recovery_25_40_min\"),\n\n \"batt_discharge_soft_lt25_a\": states(\"input_number.victron_evcs_batt_discharge_soft_lt25_a\"),\n \"batt_discharge_hard_lt25_a\": states(\"input_number.victron_evcs_batt_discharge_hard_lt25_a\"),\n \"batt_charge_reserve_lt25_a\": states(\"input_number.victron_evcs_batt_charge_reserve_lt25_a\"),\n \"batt_soft_tol_lt25_min\": states(\"input_number.victron_evcs_batt_soft_tol_lt25_min\"),\n \"batt_hard_tol_lt25_sec\": states(\"input_number.victron_evcs_batt_hard_tol_lt25_sec\"),\n \"batt_recovery_lt25_min\": states(\"input_number.victron_evcs_batt_recovery_lt25_min\"),\n\n \"evcs_delivery_ratio_ema\": states(\"input_number.victron_evcs_delivery_ratio_ema\"),\n \"evcs_delivery_noise_ema\": states(\"input_number.victron_evcs_delivery_noise_ema\"),\n \"evcs_no_demand_score_ema\": states(\"input_number.victron_evcs_no_demand_score_ema\"),\n \"evcs_no_demand_semantic_active\": states(\"input_boolean.victron_evcs_no_demand_semantic_active\"),\n \"evcs_no_demand_since_at\": states(\"input_datetime.victron_evcs_no_demand_since_at\"),\n \"evcs_no_demand_filter_eval_at\": states(\"input_datetime.victron_evcs_no_demand_filter_eval_at\")\n} | tojson }}\n" + "value": "{{ {\n \"soc_percent\": states(\"sensor.victron_battery_soc\"),\n \"battery_current_a\": states(\"sensor.victron_battery_current\"),\n\n \"pv_power_w\": states(\"sensor.victron_pv_power_system\"),\n \"pv_power_10m_avg_w\": states(\"sensor.victron_pv_power_10m_avg\"),\n \"pv_trend_w\": states(\"sensor.victron_pv_power_trend_w\"),\n\n \"mppt_operation_modes\": states.sensor\n | selectattr('entity_id','search','mppt')\n | selectattr('entity_id','search','operation_mode')\n | map(attribute='state') | join(','),\n\n \"house_ac_power_w\": states(\"sensor.victron_consumption_power_l1\"),\n \"house_ac_power_prev_w\": states(\"sensor.victron_consumption_power_l1\"),\n\n \"grid_power_w\": states(\"sensor.victron_grid_power_l1\"),\n \"grid_state\": states(\"switch.edf_general_ok_switch\"),\n \"victron_acin1_available\": states(\"sensor.victron_ac_in1_available\"),\n\n \n \"acin1_last_changed_ts\": as_timestamp(states.sensor.victron_ac_in1_available.last_changed, 0) if states.sensor.victron_ac_in1_available is not none else 0,\n \"grid_switch_last_changed_ts\": as_timestamp(states.switch.edf_general_ok_switch.last_changed, 0) if states.switch.edf_general_ok_switch is not none else 0,\n \"grid_settle_seconds\": states(\"input_number.evcs_grid_settle_seconds\"),\n \"grid_setpoint_w\": states(\"number.gx_device_ac_power_setpoint\"),\n \"grid_setpoint_idle_w\": states(\"input_number.evcs_grid_setpoint_idle_w\"),\n\n \"today_remaining_kwh\": states(\"sensor.energy_production_today_remaining\"),\n \"tomorrow_kwh\": states(\"sensor.energy_production_tomorrow\"),\n\n \"evcs_device_connected\": states(\"binary_sensor.victron_evcs_device_connected\"),\n \"evcs_vehicle_connected\": states(\"binary_sensor.victron_evcs_vehicle_connected\"),\n \"evcs_status_raw\": states(\"sensor.victron_evcs_status_raw\"),\n \"evcs_mode_sensor\": states(\"sensor.victron_evcs_mode\"),\n \"evcs_mode_fallback\": states(\"input_text.sensor_victron_evcs_mode\"),\n \"evcs_set_current_a\": states(\"sensor.victron_evcs_set_current\"),\n \"evcs_command_current_a\": states(\"number.victron_evcs_set_current_command\"),\n \"evcs_current_a\": states(\"sensor.victron_evcs_current\"),\n \"evcs_ac_power_w\": states(\"sensor.victron_evcs_ac_power\"),\n \"evcs_charging_time\": states(\"sensor.victron_evcs_charging_time\"),\n \"evcs_session_energy_kwh\": states(\"sensor.evcs_hq2239dnt7p_last_session_energy\"),\n \"evcs_charging_switch\": states(\"switch.victron_evcs_charging\"),\n \"evcs_auto_start_switch\": states(\"switch.victron_evcs_auto_start\"),\n\n \"controller_enabled\": states(\"input_boolean.victron_evcs_surplus_auto_enabled\"),\n \"notifications_enabled\": states(\"input_boolean.victron_evcs_surplus_notifications\"),\n \"hard_stop_enabled\": states(\"input_boolean.victron_evcs_hard_stop_enabled\"),\n \"charge_permission_now\": states(\"input_boolean.victron_evcs_charge_permission_now\"),\n \"control_latch\": states(\"input_boolean.victron_evcs_control_latch\"),\n \"departure_priority_enabled\": states(\"input_boolean.victron_evcs_departure_priority_enabled\"),\n \"forecast_mode_enabled\": states(\"input_boolean.victron_evcs_forecast_mode_enabled\"),\n\n \"target_current_auto_a\": states(\"input_number.victron_evcs_target_current_auto\"),\n \"budget_remaining_kwh\": states(\"input_number.victron_evcs_budget_remaining_kwh\"),\n \"projected_end_soc_after_charge\": states(\"input_number.victron_evcs_projected_end_soc_after_charge\"),\n\n \"pv_start_min_w\": states(\"input_number.victron_evcs_pv_start_min_w\"),\n \"pv_hold_min_w\": states(\"input_number.victron_evcs_pv_hold_min_w\"),\n \"house_ac_headroom_w\": states(\"input_number.victron_evcs_house_ac_headroom_w\"),\n \"battery_discharge_soft_a\": states(\"input_number.victron_evcs_battery_discharge_soft_a\"),\n \"battery_discharge_hard_a\": states(\"input_number.victron_evcs_battery_discharge_hard_a\"),\n \"battery_reserve_up_a\": states(\"input_number.victron_evcs_battery_reserve_up_a\"),\n \"battery_neutral_band_a\": states(\"input_number.victron_evcs_battery_neutral_band_a\"),\n \"soc_start_min\": states(\"input_number.victron_evcs_soc_start_min\"),\n \"modules_en_service\": states(\"input_number.evcs_balance_modules_en_service\"),\n\n \"bms_max_discharge_current_a\": states(\"sensor.airtria_8_us2000c_maximum_allowed_discharge_current\"),\n \"bms_max_charge_current_a\": states(\"sensor.airtria_8_us2000c_maximum_allowed_charge_current\"),\n \"soc_stop_min\": states(\"input_number.victron_evcs_soc_stop_min\"),\n \"current_min_a\": states(\"input_number.victron_evcs_current_min_a\"),\n \"current_max_auto_a\": states(\"input_number.victron_evcs_current_max_auto_a\"),\n \"grid_current_max_a\": states(\"input_number.evcs_plafond_courant_edf_on\"),\n \"current_step_up_a\": states(\"input_number.victron_evcs_current_step_up_a\"),\n \"current_step_down_a\": states(\"input_number.victron_evcs_current_step_down_a\"),\n \"current_change_cooldown_seconds\": states(\"input_number.victron_evcs_current_change_cooldown_seconds\"),\n \"min_run_minutes\": states(\"input_number.victron_evcs_min_run_minutes\"),\n \"min_stop_minutes\": states(\"input_number.victron_evcs_min_stop_minutes\"),\n\n \"required_energy_kwh\": states(\"input_number.victron_evcs_required_energy_kwh\"),\n \"soc_comfort_target\": states(\"input_number.victron_evcs_soc_comfort_target\"),\n \"end_of_day_soc_guard\": states(\"input_number.victron_evcs_end_of_day_soc_guard\"),\n\n \"base_load_remaining_kwh\": states(\"input_number.victron_base_load_remaining_kwh\"),\n \"flexible_safety_margin_kwh\": states(\"input_number.victron_flexible_safety_margin_kwh\"),\n \"end_of_day_soc_target\": states(\"input_number.victron_end_of_day_soc_target\"),\n \"ac_loads_max_safe_w\": states(\"input_number.victron_ac_loads_max_safe_w\"),\n\n \"battery_full_soc\": states(\"input_number.victron_evcs_battery_full_soc\"),\n \"battery_full_forecast_min_kwh\": states(\"input_number.victron_evcs_battery_full_forecast_min_kwh\"),\n \"forecast_commit_soc_floor\": states(\"input_number.victron_evcs_forecast_commit_soc_floor\"),\n \"forecast_commit_min_kwh\": states(\"input_number.victron_evcs_forecast_commit_min_kwh\"),\n\n \"cloud_debt_kwh\": states(\"input_number.victron_evcs_cloud_debt_kwh\"),\n \"cloud_debt_max_kwh\": states(\"input_number.victron_evcs_cloud_debt_max_kwh\"),\n \"cloud_tolerance_minutes\": states(\"input_number.victron_evcs_cloud_tolerance_minutes\"),\n \"cloud_debt_started_at\": states(\"input_datetime.victron_evcs_cloud_debt_started_at\"),\n \"battery_soft_breach_at\": states(\"input_text.victron_evcs_battery_soft_breach_at\"),\n \"operating_mode_helper\": states(\"input_text.victron_evcs_operating_mode\"),\n\n \"departure_time\": states(\"input_datetime.victron_evcs_departure_time\"),\n \"departure_time_jeep\": states(\"input_datetime.victron_evcs_departure_time_jeep\"),\n \"evcs_vehicle\": states(\"input_select.victron_evcs_vehicle\"),\n \"allow_grid_departure_urgent\": states(\"input_boolean.victron_evcs_allow_grid_departure_urgent\"),\n \"last_start_at\": states(\"input_datetime.victron_evcs_last_start_at\"),\n \"last_stop_at\": states(\"input_datetime.victron_evcs_last_stop_at\"),\n \"last_current_change_at\": states(\"input_datetime.victron_evcs_last_current_change_at\"),\n\n \"day_start_time\": states(\"input_datetime.victron_flexible_day_start_time\"),\n \"day_stop_time\": states(\"input_datetime.victron_flexible_day_stop_time\"),\n\n \"vebus_overload\": states(\"binary_sensor.victron_ve_bus_overload\"),\n \"vebus_l1_overload\": states(\"binary_sensor.victron_ve_bus_l1_overload\"),\n \"vebus_low_battery\": states(\"binary_sensor.victron_ve_bus_low_battery\"),\n \"vebus_l1_low_battery\": states(\"binary_sensor.victron_ve_bus_l1_low_battery\"),\n\n \"vebus_ac_out_l1_power_w\": states(\"sensor.victron_ve_bus_ac_out_l1_power\"),\n \"vebus_ac_out_l1_current_a\": states(\"sensor.victron_ve_bus_ac_out_l1_current\"),\n \"vebus_ac_out_l1_voltage_v\": states(\"sensor.victron_ve_bus_ac_out_l1_voltage\"),\n\n \"vebus_dc_voltage_v\": states(\"sensor.victron_ve_bus_dc_voltage\"),\n \"vebus_dc_current_a\": states(\"sensor.victron_ve_bus_dc_current\"),\n \"vebus_dc_power_w\": states(\"sensor.victron_ve_bus_dc_power_system\"),\n\n \"vebus_state\": states(\"sensor.victron_ve_bus_state\"),\n \"vebus_main_state\": states(\"sensor.victron_ve_bus_main_state\"),\n\n \"last_signature\": states(\"input_text.victron_evcs_control_last_signature\"),\n\n \"hc_night_start_time\": states(\"input_datetime.victron_evcs_hc_night_start\"),\n \"hc_night_stop_time\": states(\"input_datetime.victron_evcs_hc_night_stop\"),\n \"morning_start_time\": states(\"input_datetime.victron_evcs_morning_start\"),\n \"morning_stop_time\": states(\"input_datetime.victron_evcs_morning_stop\"),\n \"hc_midday_start_time\": states(\"input_datetime.victron_evcs_hc_midday_start\"),\n \"hc_midday_stop_time\": states(\"input_datetime.victron_evcs_hc_midday_stop\"),\n \"evening_start_time\": states(\"input_datetime.victron_evcs_evening_start\"),\n \"evening_stop_time\": states(\"input_datetime.victron_evcs_evening_stop\"),\n\n \"allow_grid_hc_night\": states(\"input_boolean.victron_evcs_allow_grid_hc_night\"),\n \"night_takeover_prev\": states(\"input_boolean.victron_evcs_night_grid_takeover_needed\"),\n \"night_grid_session_committed_prev\": states(\"input_boolean.victron_evcs_night_grid_session_committed\"),\n \"prev_surplus_state\": states(\"input_text.victron_evcs_surplus_state\"),\n \"evcs_night_session_start_soc\": states(\"input_text.victron_evcs_night_session_start_soc\"),\n \"evcs_night_session_start_at\": states(\"input_text.victron_evcs_night_session_start_at\"),\n \"advisor_apply_night_target\": states(\"input_boolean.evcs_advisor_apply_night_target\"),\n \"advisor_night_target_soc\": states(\"input_number.evcs_advisor_night_target_soc\"),\n \"advisor_status\": states(\"input_text.evcs_advisor_status\"),\n \"advisor_last_run\": states(\"input_text.evcs_advisor_last_run\"),\n\n \"balance_required_soc\": states(\"input_number.evcs_balance_required_soc\"),\n \"balance_energy_to_cover_kwh\": states(\"input_number.evcs_balance_energy_to_cover_kwh\"),\n \"balance_status\": states(\"input_text.evcs_balance_status\"),\n \"balance_last_run\": states(\"input_text.evcs_balance_last_run\"),\n \"allow_grid_hc_midday\": states(\"input_boolean.victron_evcs_allow_grid_hc_midday\"),\n \"probe_enabled\": states(\"input_boolean.victron_evcs_probe_enabled\"),\n\n \"probe_minutes\": states(\"input_number.victron_evcs_probe_minutes\"),\n \"probe_retry_minutes\": states(\"input_number.victron_evcs_probe_retry_minutes\"),\n \"probe_current_a\": states(\"input_number.victron_evcs_probe_current_a\"),\n\n \"grid_battery_soft_a\": states(\"input_number.victron_evcs_grid_battery_soft_a\"),\n \"grid_battery_hard_a\": states(\"input_number.victron_evcs_grid_battery_hard_a\"),\n\n \"morning_probe_pv_avg_min_w\": states(\"input_number.victron_evcs_morning_probe_pv_avg_min_w\"),\n \"morning_probe_pv_trend_min_w\": states(\"input_number.victron_evcs_morning_probe_pv_trend_min_w\"),\n \"midday_probe_pv_avg_min_w\": states(\"input_number.victron_evcs_midday_probe_pv_avg_min_w\"),\n \"afternoon_probe_pv_avg_min_w\": states(\"input_number.victron_evcs_afternoon_probe_pv_avg_min_w\"),\n \"afternoon_probe_soc_min\": states(\"input_number.victron_evcs_afternoon_probe_soc_min\"),\n \"afternoon_battery_max_discharge_a\": states(\"input_number.victron_evcs_afternoon_battery_max_discharge_a\"),\n \"morning_soc_min\": states(\"input_number.victron_evcs_morning_soc_min\"),\n \"midday_soc_min\": states(\"input_number.victron_evcs_midday_soc_min\"),\n \"evening_soc_start_min\": states(\"input_number.victron_evcs_evening_soc_start_min\"),\n \"evening_soc_stop_min\": states(\"input_number.victron_evcs_evening_soc_stop_min\"),\n\n \"morning_battery_max_discharge_a\": states(\"input_number.victron_evcs_morning_battery_max_discharge_a\"),\n \"midday_battery_max_discharge_a\": states(\"input_number.victron_evcs_midday_battery_max_discharge_a\"),\n \"evening_battery_max_discharge_a\": states(\"input_number.victron_evcs_evening_battery_max_discharge_a\"),\n\n \"last_block_reason\": states(\"input_text.victron_evcs_last_block_reason\"),\n \"blocked_until\": states(\"input_datetime.victron_evcs_blocked_until\"),\n \"probe_started_at\": states(\"input_datetime.victron_evcs_probe_started_at\"),\n\n \"victron_evcs_strategy\": states(\"input_select.victron_evcs_strategy\"),\n \"evcs_priority_manual_override\": states(\"input_boolean.victron_evcs_priority_manual_override\"),\n \"evcs_priority_manual_mode\": states(\"input_select.victron_evcs_priority_manual_mode\"),\n \"evcs_priority_manual_reason\": states(\"input_text.victron_evcs_priority_manual_reason\"),\n \"evcs_priority_manual_until\": states(\"input_datetime.victron_evcs_priority_manual_until\"),\n\n \"house_spike_grace_minutes\": states(\"input_number.victron_evcs_house_spike_grace_minutes\"),\n \"solar_potential_grace_minutes\": states(\"input_number.victron_evcs_solar_potential_grace_minutes\"),\n \"step_up_cooldown_seconds\": states(\"input_number.victron_evcs_step_up_cooldown_seconds\"),\n \"step_down_cooldown_seconds\": states(\"input_number.victron_evcs_step_down_cooldown_seconds\"),\n \"force_mode_auto_revert_minutes\": states(\"input_number.victron_evcs_force_mode_auto_revert_minutes\"),\n\n \"overload_step_down_a\": states(\"input_number.victron_evcs_overload_step_down_a\"),\n \"overload_hold_seconds\": states(\"input_number.victron_evcs_overload_hold_seconds\"),\n \"overload_stop_after_seconds\": states(\"input_number.victron_evcs_overload_stop_after_seconds\"),\n\n \"batt_discharge_soft_gt90_a\": states(\"input_number.victron_evcs_batt_discharge_soft_gt90_a\"),\n \"batt_discharge_hard_gt90_a\": states(\"input_number.victron_evcs_batt_discharge_hard_gt90_a\"),\n \"batt_charge_reserve_gt90_a\": states(\"input_number.victron_evcs_batt_charge_reserve_gt90_a\"),\n \"batt_soft_tol_gt90_min\": states(\"input_number.victron_evcs_batt_soft_tol_gt90_min\"),\n \"batt_hard_tol_gt90_sec\": states(\"input_number.victron_evcs_batt_hard_tol_gt90_sec\"),\n \"batt_recovery_gt90_min\": states(\"input_number.victron_evcs_batt_recovery_gt90_min\"),\n\n \"batt_discharge_soft_80_90_a\": states(\"input_number.victron_evcs_batt_discharge_soft_80_90_a\"),\n \"batt_discharge_hard_80_90_a\": states(\"input_number.victron_evcs_batt_discharge_hard_80_90_a\"),\n \"batt_charge_reserve_80_90_a\": states(\"input_number.victron_evcs_batt_charge_reserve_80_90_a\"),\n \"batt_soft_tol_80_90_min\": states(\"input_number.victron_evcs_batt_soft_tol_80_90_min\"),\n \"batt_hard_tol_80_90_sec\": states(\"input_number.victron_evcs_batt_hard_tol_80_90_sec\"),\n \"batt_recovery_80_90_min\": states(\"input_number.victron_evcs_batt_recovery_80_90_min\"),\n\n \"batt_discharge_soft_60_80_a\": states(\"input_number.victron_evcs_batt_discharge_soft_60_80_a\"),\n \"batt_discharge_hard_60_80_a\": states(\"input_number.victron_evcs_batt_discharge_hard_60_80_a\"),\n \"batt_charge_reserve_60_80_a\": states(\"input_number.victron_evcs_batt_charge_reserve_60_80_a\"),\n \"batt_soft_tol_60_80_min\": states(\"input_number.victron_evcs_batt_soft_tol_60_80_min\"),\n \"batt_hard_tol_60_80_sec\": states(\"input_number.victron_evcs_batt_hard_tol_60_80_sec\"),\n \"batt_recovery_60_80_min\": states(\"input_number.victron_evcs_batt_recovery_60_80_min\"),\n\n \"batt_discharge_soft_40_60_a\": states(\"input_number.victron_evcs_batt_discharge_soft_40_60_a\"),\n \"batt_discharge_hard_40_60_a\": states(\"input_number.victron_evcs_batt_discharge_hard_40_60_a\"),\n \"batt_charge_reserve_40_60_a\": states(\"input_number.victron_evcs_batt_charge_reserve_40_60_a\"),\n \"batt_soft_tol_40_60_min\": states(\"input_number.victron_evcs_batt_soft_tol_40_60_min\"),\n \"batt_hard_tol_40_60_sec\": states(\"input_number.victron_evcs_batt_hard_tol_40_60_sec\"),\n \"batt_recovery_40_60_min\": states(\"input_number.victron_evcs_batt_recovery_40_60_min\"),\n\n \"batt_discharge_soft_25_40_a\": states(\"input_number.victron_evcs_batt_discharge_soft_25_40_a\"),\n \"batt_discharge_hard_25_40_a\": states(\"input_number.victron_evcs_batt_discharge_hard_25_40_a\"),\n \"batt_charge_reserve_25_40_a\": states(\"input_number.victron_evcs_batt_charge_reserve_25_40_a\"),\n \"batt_soft_tol_25_40_min\": states(\"input_number.victron_evcs_batt_soft_tol_25_40_min\"),\n \"batt_hard_tol_25_40_sec\": states(\"input_number.victron_evcs_batt_hard_tol_25_40_sec\"),\n \"batt_recovery_25_40_min\": states(\"input_number.victron_evcs_batt_recovery_25_40_min\"),\n\n \"batt_discharge_soft_lt25_a\": states(\"input_number.victron_evcs_batt_discharge_soft_lt25_a\"),\n \"batt_discharge_hard_lt25_a\": states(\"input_number.victron_evcs_batt_discharge_hard_lt25_a\"),\n \"batt_charge_reserve_lt25_a\": states(\"input_number.victron_evcs_batt_charge_reserve_lt25_a\"),\n \"batt_soft_tol_lt25_min\": states(\"input_number.victron_evcs_batt_soft_tol_lt25_min\"),\n \"batt_hard_tol_lt25_sec\": states(\"input_number.victron_evcs_batt_hard_tol_lt25_sec\"),\n \"batt_recovery_lt25_min\": states(\"input_number.victron_evcs_batt_recovery_lt25_min\"),\n\n \"evcs_delivery_ratio_ema\": states(\"input_number.victron_evcs_delivery_ratio_ema\"),\n \"evcs_delivery_noise_ema\": states(\"input_number.victron_evcs_delivery_noise_ema\"),\n \"evcs_no_demand_score_ema\": states(\"input_number.victron_evcs_no_demand_score_ema\"),\n \"evcs_no_demand_semantic_active\": states(\"input_boolean.victron_evcs_no_demand_semantic_active\"),\n \"evcs_no_demand_since_at\": states(\"input_datetime.victron_evcs_no_demand_since_at\"),\n \"evcs_no_demand_filter_eval_at\": states(\"input_datetime.victron_evcs_no_demand_filter_eval_at\")\n} | tojson }}\n" } ] },