HC de midi : consigne qui ne descend plus avec un manque batterie, voiture autorisee au-dessus de 35 % en session, tension de recharge 51,5 V
This commit is contained in:
@@ -2823,6 +2823,52 @@ export const scenarios = [
|
||||
},
|
||||
expect: { profile: 'midday_hc_or_solar', sourceMode: 'grid_hc_allowed', takeoverNeeded: true },
|
||||
},
|
||||
{
|
||||
// RELEVE 09/10 13:59 : JEEP branchee 13:01 a 52 %, SOC 55-57, session de midi
|
||||
// engagee (jour faible), EDF ferme : « Conditions de demarrage non reunies ».
|
||||
// La garde gridAllowedBySoc (SOC <= 35 hors nuit) bloquait le demarrage. Le
|
||||
// scenario precedent ne verifiait que la source, pas la charge.
|
||||
id: 'hc-midi-session-engagee-voiture-demarre-soc-55',
|
||||
label: 'RELEVE 09/10 13:59 — midi, session engagee, EDF ferme, SOC 55 : la JEEP DEMARRE sur le reseau',
|
||||
time: MIDDAY,
|
||||
overrides: {
|
||||
evcs_vehicle_connected: 'on', evcs_device_connected: 'on',
|
||||
grid_state: 'on', victron_acin1_available: '1',
|
||||
night_grid_session_committed_prev: 'on',
|
||||
soc_percent: '55', battery_current_a: '30',
|
||||
pv_power_w: '1750', pv_power_10m_avg_w: '1700', pv_trend_w: '0',
|
||||
house_ac_power_w: '1650', vebus_ac_out_l1_power_w: '1650',
|
||||
evcs_ac_power_w: '0',
|
||||
balance_required_soc: '100', balance_energy_to_cover_kwh: '0.33',
|
||||
balance_grid_energy_needed_kwh: '12.9',
|
||||
balance_status: 'ok', balance_last_run: '08/08 12:50',
|
||||
balance_vehicle_grid_needed: 'off', balance_ecs_nuit: 'on',
|
||||
},
|
||||
expect: { profile: 'midday_hc_or_solar', sourceMode: 'grid_hc_allowed', desiredCharging: true },
|
||||
},
|
||||
{
|
||||
id: 'consigne-hc-midi-chargeur-bride-batterie-loin-de-sa-limite',
|
||||
label: 'RELEVE 09/10 13:59 — midi, manque 12,9 kWh, un chargeur bride, batterie a 32 A sur 140 : la consigne NE DESCEND PAS a la maison',
|
||||
time: MIDDAY,
|
||||
overrides: {
|
||||
evcs_vehicle_connected: 'off', evcs_device_connected: 'on',
|
||||
grid_state: 'on', victron_acin1_available: '1',
|
||||
night_grid_session_committed_prev: 'on',
|
||||
soc_percent: '57', battery_current_a: '32',
|
||||
pv_power_w: '1750', pv_power_10m_avg_w: '1700', pv_trend_w: '0',
|
||||
mppt_operation_modes: 'voltage_current_limited,mppt_active,mppt_active,mppt_active,mppt_active,mppt_active,mppt_active',
|
||||
house_ac_power_w: '1650', vebus_ac_out_l1_power_w: '1650',
|
||||
evcs_ac_power_w: '0',
|
||||
grid_setpoint_w: '2524',
|
||||
dvcc_max_charge_current_a: '140',
|
||||
balance_required_soc: '100', balance_energy_to_cover_kwh: '0.33',
|
||||
balance_grid_energy_needed_kwh: '12.9',
|
||||
balance_status: 'ok', balance_last_run: '08/08 12:50',
|
||||
balance_ecs_nuit: 'on',
|
||||
},
|
||||
// Maison 1 650 + 140 A x 52,9 V (tension de reference) = 9 059 W ; sans le correctif : 2 087 W (descente).
|
||||
expect: { gridSetpointW: 9059 },
|
||||
},
|
||||
{
|
||||
id: 'consigne-bilan-plancher-nuage-exclut-la-batterie',
|
||||
label: 'CONSIGNE 18/09 — midi, soleil bride, manque batterie, PAS de voiture : le terme batterie ne doit PAS remonter le plancher nuage',
|
||||
@@ -2842,7 +2888,9 @@ export const scenarios = [
|
||||
victron_evcs_strategy: 'force_grid_now',
|
||||
evcs_vehicle_connected: 'off', evcs_device_connected: 'on',
|
||||
grid_state: 'on', victron_acin1_available: '1',
|
||||
soc_percent: '35', battery_current_a: '20',
|
||||
// 09/10 : batterie a sa limite (170 A sur 180) -> la descente est legitime ;
|
||||
// a 20 A elle ne l'est plus (scenario consigne-hc-midi-chargeur-bride-batterie-loin-de-sa-limite).
|
||||
soc_percent: '35', battery_current_a: '170',
|
||||
pv_power_w: '7000', pv_power_10m_avg_w: '6500', pv_trend_w: '0',
|
||||
mppt_operation_modes: 'voltage_current_limited,voltage_current_limited,mppt_active,mppt_active,mppt_active,mppt_active,mppt_active',
|
||||
house_ac_power_w: '900', vebus_ac_out_l1_power_w: '900',
|
||||
|
||||