Update AGENTS.md with Qwen3-VL screen analysis procedure, add MANUEL_COMPLET.md and vision-notes.md
This commit is contained in:
172
docs/vision-notes.md
Normal file
172
docs/vision-notes.md
Normal file
@@ -0,0 +1,172 @@
|
||||
# OCR brut
|
||||
|
||||
[Image 1]
|
||||
AIRTRIA / MR TALLAGRAND 3,1KW (2X5RECOM) LANNION
|
||||
Dernière mise à jour: OK 20:14
|
||||
Temps réel
|
||||
Temps: 24°C
|
||||
Charges CA 3615 W
|
||||
L1 3615 W 49.9 Hz
|
||||
Charguer VE 1256 W
|
||||
Statut charge
|
||||
Véhicule: Guest EV
|
||||
Temps de charge: 1h, 53m, 43s
|
||||
Mode: Manual
|
||||
Courant de charge: 6.0 A
|
||||
Énergie chargée: 4 kWh
|
||||
Énergie totale: 3266 kWh
|
||||
Décharge en cours: 78.0%
|
||||
Tension: 49.75 V
|
||||
Courant: -19.9 A
|
||||
Température: 25°C
|
||||
Chargeur PV: 2421 W
|
||||
AIRTRIA MPPT1 164 V 0.9 A 141 W
|
||||
V1 57.77 V 3.7 A 215 W
|
||||
V2 - - -
|
||||
MPPT 450/200 HQ2449YR9PT-Solar 1 257 V 1.6 A 409 W
|
||||
MPPT 450/200 HQ2449YR9PT-Solar 2 281 V 1.6 A 447 W
|
||||
MPPT 450/200 HQ2449YR9PT-Solar 3 331 V 1.4 A 456 W
|
||||
MPPT 450/200 HQ2449YR9PT-Solar 4 68.62 V 5.5 A 375 W
|
||||
AIRTRIA MP2 78.0% 49.60 V -77.1 A -3605 W Discharging
|
||||
|
||||
[Image 2]
|
||||
EVCS Master
|
||||
Vue borne / session / stratégie / énergie
|
||||
Charge EVCS active
|
||||
État borne
|
||||
Statut global
|
||||
EVCS: unavailable - Mode Manuell - 6.0 A
|
||||
Statut FR: Indisponible
|
||||
Mode FR: Manuell
|
||||
Statut brut: 2
|
||||
Mode brut: 0
|
||||
EVCS détecté: Connecté
|
||||
Branché
|
||||
Durée charge: 1h 54m
|
||||
Contrôleur surplus actif
|
||||
Session
|
||||
Courant / puissance / énergie
|
||||
Courant EVCS: 6.0 A
|
||||
Session en cours: 1234 W - 6.0 A - Consigne 6.0 A - 1h 54m
|
||||
Puissance EVCS: 1234 W
|
||||
Courant réel: 6.0 A
|
||||
Consigne lue: 6 A
|
||||
Durée charge: 1h 54m
|
||||
Énergie session: Inconnu
|
||||
Stratégie & décision
|
||||
Mode utilisateur: auto_solar_plus - Profil: evening_high_soc - Décision: hold - Source: Solaire
|
||||
Paramètres utilisateur
|
||||
Véhicule cible: Jeep
|
||||
Énergie demandée: 10.5 kWh
|
||||
Priorité départ: On
|
||||
Heure départ: 8:50
|
||||
|
||||
[Image 3]
|
||||
EVCS Master
|
||||
Énergie demandée: 10,5 kWh
|
||||
Priorité départ: On
|
||||
Heure départ: 8:50
|
||||
Stratégie EVCS: auto_solar_plus
|
||||
Réseau HC nuit: On
|
||||
Réseau HC midi: On
|
||||
Contrôleur surplus actif: On
|
||||
Décision contrôleur
|
||||
Profil actif: evening_high_soc
|
||||
État interne: hold_min_run
|
||||
Décision logique: hold
|
||||
Source autorisée: Solaire
|
||||
Raison courte: Maintien jusqu'au temps mini ON | VehicleDemandFilter déliv
|
||||
Dernier blocage: none
|
||||
Blocqué jusqu'à: 17/07/2026
|
||||
Contexte énergie
|
||||
Batterie / PV / réseau
|
||||
Contexte instantané: SOC 78.0% - PV 2758 W - Maison 3645 W - Grid 0 W
|
||||
SOC batterie: 78.0%
|
||||
Courant batterie: -22.70 A
|
||||
Puissance PV: 2758 W
|
||||
Charges maison: 3645 W
|
||||
Puissance réseau: 0 W
|
||||
Réseau EDF: Off
|
||||
Actions rapides
|
||||
Contrôle direct EVCS
|
||||
Charge: On
|
||||
Contrôleur surplus: Activé
|
||||
|
||||
[Image 4]
|
||||
EVCS Master
|
||||
ON
|
||||
Activé
|
||||
Véhicule: Branché
|
||||
Courant demandé: 6 A
|
||||
Commandes manuelles
|
||||
Start / Stop charge: On
|
||||
Courant demandé: 6 A
|
||||
Permission charge: On
|
||||
Latch contrôle: On
|
||||
Auto Start borne (diagnostic): Off
|
||||
BOOST EDF 28A
|
||||
Retour normal
|
||||
Plafonds courant EVCS
|
||||
Plafond EDF ON tous modes: 28 A
|
||||
Plafond modes auto: 28 A
|
||||
Diagnostic
|
||||
Identité / version / brut
|
||||
Produit: EV Charging Station
|
||||
Nom borne: EVCS-HQ229DNT7P
|
||||
Numéro de série: HQ229DNT7P
|
||||
Firmware: 13375
|
||||
Statut brut: 2
|
||||
Mode brut: 0
|
||||
Auto Start borne: Off
|
||||
Dernier start: 17/07/2026 19:54
|
||||
Dernier stop: 17/07/2026 19:30
|
||||
Dernier changement courant: 17/07/2026 19:54
|
||||
Début probe: 31/03/2026 0:00
|
||||
Début cloud deb: 16/07/2026 19:41
|
||||
Cloud deb: 0.49 kWh
|
||||
Signature: hold_min_runprofile=evening_high_socsource=solar_onlych
|
||||
|
||||
# Éléments UI
|
||||
- Charge EVCS active
|
||||
- Mode: Manual (mais stratégie configurée: auto_solar_plus)
|
||||
- Courant EVCS: 6.0 A
|
||||
- SOC batterie: 78.0%
|
||||
- Puissance PV: 2758 W
|
||||
- Réseau EDF: Off (autoconsommation sans injection)
|
||||
- Stratégie: auto_solar_plus
|
||||
- Profil actif: evening_high_soc
|
||||
- Contrôleur surplus: Activé
|
||||
|
||||
# Erreurs visibles
|
||||
- Mode Manual actif alors que stratégie auto_solar_plus est configurée
|
||||
- Statut FR: Indisponible (mode français non disponible)
|
||||
- EVCS: unavailable (même si charge active)
|
||||
- Grid 0 W - pas d'injection réseau (configuration recherchée)
|
||||
- Tension batterie 49.60V - proche de la tension de Floating
|
||||
|
||||
# État actuel
|
||||
- Session de charge en cours (1h 54m)
|
||||
- Courant de charge: 6.0 A (mode manuel)
|
||||
- SOC batterie: 78.0% (en décharge: -22.70A)
|
||||
- Puissance PV: 2758 W
|
||||
- Grid: 0 W (autoconsommation pure, pas d'injection)
|
||||
- Maison: 3645 W de consommation
|
||||
- Contrôleur surplus actif
|
||||
- Décision: hold (maintien du courant minimum)
|
||||
- Profil: evening_high_soc
|
||||
|
||||
# Actions recommandées
|
||||
- Vérifier si le passage en mode auto_solar_plus est souhaité (actuellement en Manual)
|
||||
- Le système est en autoconsommation sans injection - comportement normal avec Grid 0W
|
||||
- La batterie se décharge (-22.70A) pour alimenter la maison + VE
|
||||
- PV 2758W couvre partiellement la consommation maison (3645W) + charge VE (1234W)
|
||||
- Le courant de charge pourrait être augmenté si plus de PV disponible
|
||||
- Surveiller le SOC pour ne pas descendre sous le seuil critique
|
||||
|
||||
# Contexte HANDOFF.md
|
||||
Suite à la session de débogage du 17/07/2026:
|
||||
- 4 bugs critiques corrigés (typo DECISION_ENGINEV2, artefacts WINDOWS_SOURCEV2, session nuit stuck, EDF rebranché en journée)
|
||||
- Configuration actuelle: soc_start_min=80%, night_target_soc=70%, battery_discharge_soft_a=0A
|
||||
- Mode sonde activé (probe_enabled: ON)
|
||||
- Système fonctionnel avec delivery 99.9%
|
||||
- EDF OFF la journée, uniquement la nuit
|
||||
Reference in New Issue
Block a user