logique de traitement erron
This commit is contained in:
188
decoupesurplus/V2/batcloudP13.js
Normal file
188
decoupesurplus/V2/batcloudP13.js
Normal file
@@ -0,0 +1,188 @@
|
||||
// =====================================================
|
||||
// LEGACY / FORECAST MODES
|
||||
// =====================================================
|
||||
const batteryFullHarvestMode =
|
||||
parsed.forecastModeEnabled &&
|
||||
context.profile !== 'night_hc' &&
|
||||
context.profile !== 'outside_window' &&
|
||||
parsed.soc >= params.batteryFullSoc &&
|
||||
parsed.todayRemainingKwh >= params.batteryFullForecastMinKwh &&
|
||||
derived.projectedEndSocAfterCharge >= (derived.endDayGuardSoc - 2);
|
||||
|
||||
const forecastCommitMode =
|
||||
parsed.forecastModeEnabled &&
|
||||
context.profile !== 'night_hc' &&
|
||||
context.profile !== 'outside_window' &&
|
||||
parsed.soc >= params.forecastCommitSocFloor &&
|
||||
parsed.todayRemainingKwh >= params.forecastCommitMinKwh &&
|
||||
derived.projectedEndSocAfterCharge >= derived.endDayGuardSoc;
|
||||
|
||||
const batteryPriorityMode =
|
||||
!batteryFullHarvestMode && !forecastCommitMode;
|
||||
|
||||
// =====================================================
|
||||
// PROFILE-BASED THRESHOLDS
|
||||
// =====================================================
|
||||
const profileSocStartFloor =
|
||||
context.profile === 'morning_solar' ? params.morningSocMin :
|
||||
context.profile === 'midday_hc_or_solar' ? params.middaySocMin :
|
||||
context.profile === 'evening_high_soc' ? params.eveningSocStartMin :
|
||||
params.socStartMin;
|
||||
|
||||
const profileSocHoldFloor =
|
||||
context.profile === 'morning_solar' ? Math.max(params.socStopMin, params.morningSocMin - 10) :
|
||||
context.profile === 'midday_hc_or_solar' ? Math.max(params.socStopMin, params.middaySocMin - 15) :
|
||||
context.profile === 'evening_high_soc' ? params.eveningSocStopMin :
|
||||
params.socStopMin;
|
||||
|
||||
const profileSpecificDischargeFloorA =
|
||||
context.profile === 'morning_solar' ? params.morningBatteryMaxDischargeA :
|
||||
context.profile === 'midday_hc_or_solar' ? params.middayBatteryMaxDischargeA :
|
||||
context.profile === 'evening_high_soc' ? params.eveningBatteryMaxDischargeA :
|
||||
params.batteryDischargeSoftA;
|
||||
|
||||
const profileBatteryDischargeFloorA =
|
||||
Math.max(profileSpecificDischargeFloorA, batteryDischargeSoftDynamicA);
|
||||
|
||||
// =====================================================
|
||||
// GRID RELAX IN force_charge_now
|
||||
// =====================================================
|
||||
// Assouplissement uniquement pour la garde réseau,
|
||||
// sans toucher aux sécurités dures globales.
|
||||
const gridForceChargeRelaxSoftA =
|
||||
strategy.forceChargeRequested && isGridSource
|
||||
? (
|
||||
parsed.soc >= 90 ? 28 :
|
||||
parsed.soc >= 80 ? 16 :
|
||||
parsed.soc >= 60 ? 8 :
|
||||
parsed.soc >= 40 ? 4 :
|
||||
0
|
||||
)
|
||||
: 0;
|
||||
|
||||
const gridForceChargeRelaxHardA =
|
||||
strategy.forceChargeRequested && isGridSource
|
||||
? (
|
||||
parsed.soc >= 90 ? 39 :
|
||||
parsed.soc >= 80 ? 29 :
|
||||
parsed.soc >= 60 ? 18 :
|
||||
parsed.soc >= 40 ? 8 :
|
||||
0
|
||||
)
|
||||
: 0;
|
||||
|
||||
const gridBatterySoftDynamicABase =
|
||||
Math.max(params.gridBatterySoftA, batteryDischargeSoftDynamicA);
|
||||
|
||||
const gridBatteryHardDynamicABase =
|
||||
Math.max(params.gridBatteryHardA, batteryDischargeHardDynamicA);
|
||||
|
||||
let gridBatterySoftDynamicA =
|
||||
gridBatterySoftDynamicABase - gridForceChargeRelaxSoftA;
|
||||
|
||||
let gridBatteryHardDynamicA =
|
||||
gridBatteryHardDynamicABase - gridForceChargeRelaxHardA;
|
||||
|
||||
// Garantit que le hard reste plus permissif que le soft d'au moins 3 A
|
||||
if (gridBatteryHardDynamicA > (gridBatterySoftDynamicA - 3)) {
|
||||
gridBatteryHardDynamicA = gridBatterySoftDynamicA - 3;
|
||||
}
|
||||
|
||||
// =====================================================
|
||||
// BASE SAFETY
|
||||
// =====================================================
|
||||
const commonSafetyStartOk =
|
||||
derived.canRunAtMinCurrent &&
|
||||
!derived.anyVebusOverload &&
|
||||
!derived.anyVebusLowBattery &&
|
||||
!derived.vebusDcVoltageSoftLow &&
|
||||
!derived.vebusAcOutSoftReached &&
|
||||
parsed.evcsDeviceConnected &&
|
||||
parsed.evcsVehicleConnected &&
|
||||
!parsed.evcsModeIsAuto;
|
||||
|
||||
const commonSafetyHoldOk =
|
||||
derived.canRunAtMinCurrent &&
|
||||
!derived.anyVebusLowBattery &&
|
||||
!derived.vebusDcVoltageHardLow &&
|
||||
parsed.evcsDeviceConnected &&
|
||||
parsed.evcsVehicleConnected &&
|
||||
!parsed.evcsModeIsAuto;
|
||||
|
||||
// =====================================================
|
||||
// START / HOLD CONDITIONS
|
||||
// =====================================================
|
||||
const solarStartOk =
|
||||
(context.sourceMode === 'solar_only' || context.sourceMode === 'solar_potential') &&
|
||||
commonSafetyStartOk &&
|
||||
parsed.soc >= profileSocStartFloor &&
|
||||
parsed.batteryCurrentA >= profileBatteryDischargeFloorA &&
|
||||
(
|
||||
context.sourceMode === 'solar_potential' ||
|
||||
parsed.pvPowerW >= context.effectivePvStartMinW
|
||||
);
|
||||
|
||||
const solarHoldOk =
|
||||
(context.sourceMode === 'solar_only' || context.sourceMode === 'solar_potential') &&
|
||||
commonSafetyHoldOk &&
|
||||
parsed.soc >= profileSocHoldFloor &&
|
||||
parsed.batteryCurrentA >= profileBatteryDischargeFloorA &&
|
||||
(
|
||||
parsed.pvPowerW >= params.pvHoldMinW ||
|
||||
cloudToleranceOk
|
||||
);
|
||||
|
||||
const gridStartOk =
|
||||
isGridSource &&
|
||||
commonSafetyStartOk &&
|
||||
parsed.gridAvailable &&
|
||||
parsed.batteryCurrentA >= gridBatterySoftDynamicA;
|
||||
|
||||
const gridHoldOk =
|
||||
isGridSource &&
|
||||
commonSafetyHoldOk &&
|
||||
parsed.gridAvailable &&
|
||||
parsed.batteryCurrentA >= gridBatteryHardDynamicA;
|
||||
|
||||
// =====================================================
|
||||
// PROBE LOGIC — STRICTEMENT LIMITÉE AU MODE PROBE
|
||||
// =====================================================
|
||||
const probeModeActive = context.sourceMode === 'hybrid_probe';
|
||||
|
||||
const probeStartOk =
|
||||
probeModeActive &&
|
||||
commonSafetyStartOk &&
|
||||
(context.morningProbeEligible || context.middayProbeEligible);
|
||||
|
||||
const probeHoldGuardOk =
|
||||
probeModeActive &&
|
||||
commonSafetyHoldOk &&
|
||||
parsed.batteryCurrentA >= profileBatteryDischargeFloorA;
|
||||
|
||||
const probeWindowActive =
|
||||
probeModeActive &&
|
||||
sessionObservedActive &&
|
||||
history.probeStartedMs !== null &&
|
||||
lifecycle.minutesSinceProbeStart !== null &&
|
||||
lifecycle.minutesSinceProbeStart < params.probeMinutes;
|
||||
|
||||
const probeElapsedReached =
|
||||
probeModeActive &&
|
||||
sessionObservedActive &&
|
||||
history.probeStartedMs !== null &&
|
||||
lifecycle.minutesSinceProbeStart !== null &&
|
||||
lifecycle.minutesSinceProbeStart >= params.probeMinutes;
|
||||
|
||||
const probeSuccessNow =
|
||||
probeModeActive &&
|
||||
sessionObservedActive &&
|
||||
history.probeStartedMs !== null &&
|
||||
(
|
||||
parsed.pvPowerW >= params.pvHoldMinW &&
|
||||
parsed.batteryCurrentA >= Math.min(0, batteryDischargeSoftDynamicA)
|
||||
);
|
||||
|
||||
const probeFailedNow =
|
||||
probeModeActive &&
|
||||
probeElapsedReached &&
|
||||
!probeSuccessNow;
|
||||
Reference in New Issue