feat: Add afternoon_probe for outside-window solar charging
- Add afternoonProbeEligible in WINDOW_SOURCEV2.js - Enable hybrid_probe sourceMode in outside_window when probe conditions met - Add afternoon probe parameters in INPUTPARSE (inputparse.js + inputparseP2.js) - Update probeStartOk in BATTERY_CLOUD_LOCKS to accept afternoon probe - Update blockStillRelevant for probe_failed to include outside_window Fixes the issue where strong afternoon sun with SOC>85% was blocked by high cloudDebt and no probe mechanism.
This commit is contained in:
@@ -10,7 +10,7 @@ const nextAllowedWindowStartMs =
|
||||
const blockActive = blockedUntilMs !== null && blockedUntilMs > nowMs + 1000;
|
||||
const blockStillRelevant =
|
||||
lastBlockReason === 'outside_window' ? profile === 'outside_window' :
|
||||
lastBlockReason === 'probe_failed' ? (profile === 'morning_solar' || profile === 'midday_hc_or_solar') :
|
||||
lastBlockReason === 'probe_failed' ? (profile === 'morning_solar' || profile === 'midday_hc_or_solar' || profile === 'outside_window') :
|
||||
lastBlockReason === 'battery_protection_stop' ? (
|
||||
batteryCurrentA < -batteryNeutralBandA || anyVebusLowBattery || vebusDcVoltageSoftLow
|
||||
) :
|
||||
@@ -133,7 +133,7 @@ const gridHoldOk =
|
||||
const probeStartOk =
|
||||
sourceMode === 'hybrid_probe' &&
|
||||
commonSafetyStartOk &&
|
||||
(morningProbeEligible || middayProbeEligible);
|
||||
(morningProbeEligible || middayProbeEligible || afternoonProbeEligible);
|
||||
const probeHoldGuardOk =
|
||||
commonSafetyHoldOk &&
|
||||
batteryCurrentA >= profileBatteryDischargeFloorA;
|
||||
|
||||
Reference in New Issue
Block a user