diff --git a/dashboards/victron_mobile.yaml b/dashboards/victron_mobile.yaml index 71fec96..4546a15 100755 --- a/dashboards/victron_mobile.yaml +++ b/dashboards/victron_mobile.yaml @@ -214,9 +214,14 @@ views: - entity: sensor.victron_pv_power_system name: Solaire color: "#fdd835" - - entity: sensor.victron_consumption_power_l1 + # Maison SANS le chauffe-eau (07/10), le chauffe-eau a part. + - entity: sensor.maison_hors_chauffe_eau name: Maison color: "#42a5f5" + - entity: input_number.victron_water_heater_observed_power_w + name: Chauffe-eau + color: "#ff9800" + curve: stepline - entity: sensor.victron_grid_power_l1 name: EDF color: "#ef5350" diff --git a/packages/evcs_chauffe_eau_nuit.yaml b/packages/evcs_chauffe_eau_nuit.yaml index 3abf5d4..8176e2c 100755 --- a/packages/evcs_chauffe_eau_nuit.yaml +++ b/packages/evcs_chauffe_eau_nuit.yaml @@ -23,3 +23,20 @@ input_text: name: "EVCS - Chauffe-eau : decision du jour" max: 255 icon: mdi:calendar-check + +# Flux d'energie de Victron Mobile (07/10/2026, demande du proprietaire) : la +# maison SANS le chauffe-eau. La prise du chauffe-eau ne donne que son compteur ; +# sa puissance est celle mesuree par le workflow ECS sur 5 min (0 quand il est +# coupe), donc la difference est lissee a l'echelle de quelques minutes. +template: + - sensor: + - name: "Maison hors chauffe-eau" + unique_id: evcs_maison_hors_chauffe_eau_w + unit_of_measurement: W + device_class: power + state_class: measurement + state: >- + {% set m = states('sensor.victron_consumption_power_l1') | float(none) %} + {% set e = states('input_number.victron_water_heater_observed_power_w') | float(0) %} + {{ [m - e, 0] | max | round(0) if m is not none else none }} + availability: "{{ states('sensor.victron_consumption_power_l1') | is_number }}"