input_number: # ===================================================== # RUNTIME HELPERS EVCS NIGHT # ===================================================== victron_evcs_night_target_soc: name: Victron EVCS Night Target SOC min: 0 max: 100 step: 0.1 mode: box unit_of_measurement: "%" icon: mdi:battery-clock initial: 35 victron_evcs_night_grid_trigger_soc: name: Victron EVCS Night Grid Trigger SOC min: 0 max: 100 step: 0.1 mode: box unit_of_measurement: "%" icon: mdi:transmission-tower initial: 35 # ===================================================== # EVCS NIGHT PARAMETERS # ===================================================== victron_evcs_night_battery_hard_floor_pct: name: Victron EVCS Night Battery Hard Floor Pct min: 0 max: 100 step: 0.1 mode: box unit_of_measurement: "%" icon: mdi:battery-alert-variant-outline initial: 22 victron_evcs_night_strong_forecast_kwh: name: Victron EVCS Night Strong Forecast Kwh min: 0 max: 80 step: 0.1 mode: box unit_of_measurement: "kWh" icon: mdi:weather-sunny initial: 18 victron_evcs_night_medium_forecast_kwh: name: Victron EVCS Night Medium Forecast Kwh min: 0 max: 80 step: 0.1 mode: box unit_of_measurement: "kWh" icon: mdi:weather-partly-cloudy initial: 10 victron_evcs_night_target_strong_forecast_pct: name: Victron EVCS Night Target Strong Forecast Pct min: 0 max: 100 step: 0.1 mode: box unit_of_measurement: "%" icon: mdi:battery-30 initial: 35 victron_evcs_night_target_medium_forecast_pct: name: Victron EVCS Night Target Medium Forecast Pct min: 0 max: 100 step: 0.1 mode: box unit_of_measurement: "%" icon: mdi:battery-50 initial: 55 victron_evcs_night_target_weak_forecast_pct: name: Victron EVCS Night Target Weak Forecast Pct min: 0 max: 100 step: 0.1 mode: box unit_of_measurement: "%" icon: mdi:battery-80 initial: 85 victron_evcs_night_battery_recovery_power_kw: name: Victron EVCS Night Battery Recovery Power Kw min: 0.1 max: 10 step: 0.1 mode: box unit_of_measurement: "kW" icon: mdi:battery-sync initial: 2.5 victron_evcs_night_departure_safety_min: name: Victron EVCS Night Departure Safety Min min: 0 max: 240 step: 1 mode: box unit_of_measurement: "min" icon: mdi:clock-alert-outline initial: 30 input_text: # ===================================================== # RUNTIME HELPERS EVCS NIGHT # ===================================================== victron_evcs_night_preferred_source_mode: name: Victron EVCS Night Preferred Source Mode max: 64 initial: "blocked" icon: mdi:source-branch victron_evcs_night_session_start_soc: name: Victron EVCS Night Session Start SOC max: 16 initial: "" icon: mdi:battery-start victron_evcs_night_session_start_at: name: Victron EVCS Night Session Start At max: 32 initial: "" icon: mdi:clock-start input_boolean: # ===================================================== # RUNTIME HELPERS EVCS NIGHT # ===================================================== victron_evcs_night_grid_takeover_needed: name: Victron EVCS Night Grid Takeover Needed icon: mdi:transmission-tower-import initial: false # ===================================================== # SESSION RESEAU UNIQUE DE LA NUIT (03/09/2026) # ===================================================== # Ecrit par le controleur EVCS, ne se regle pas a la main. # # ON = pendant CETTE session de nuit, le bilan energetique a constate que la # batterie ne couvrait pas la nuit, et on s'est engage a utiliser la fenetre # d'heures creuses en UNE session continue. # # Ce bit existe pour que le relachement ne depende PAS d'un seuil de SOC : # engagement sur le bilan, relachement a la FIN DE LA FENETRE. Sans lui, tout # relachement sur seuil rouvre l'oscillateur corrige le 27/08 — et il le # rouvrirait sur une grandeur fausse, la conversion kWh -> points de SOC du # bilan etant lineaire (15 kWh) alors que la jauge vaut ~17 kWh au-dessus de # 42 % et s'effondre a 8-12 kWh en dessous (mesures du 03/09). victron_evcs_night_grid_session_committed: name: Victron EVCS Night - Session reseau engagee icon: mdi:transmission-tower initial: false victron_evcs_night_battery_recovery_urgent: name: Victron EVCS Night Battery Recovery Urgent icon: mdi:battery-alert initial: false victron_evcs_night_session_active: name: Victron EVCS Night Session Active icon: mdi:car-electric initial: false