458 lines
55 KiB
JSON
458 lines
55 KiB
JSON
{
|
|
"updatedAt": "2026-07-09T21:45:53.243Z",
|
|
"createdAt": "2026-03-13T01:18:19.435Z",
|
|
"id": "cTeeHy4ePiVeELLh",
|
|
"name": "Victron - Auto Charge Manager V1.2",
|
|
"description": null,
|
|
"active": true,
|
|
"isArchived": false,
|
|
"nodes": [
|
|
{
|
|
"parameters": {
|
|
"rule": {
|
|
"interval": [
|
|
{
|
|
"field": "minutes"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"id": "3bc36d27-0e92-4207-bbde-7f23efbc1881",
|
|
"name": "Schedule Trigger",
|
|
"type": "n8n-nodes-base.scheduleTrigger",
|
|
"typeVersion": 1.2,
|
|
"position": [
|
|
0,
|
|
0
|
|
]
|
|
},
|
|
{
|
|
"parameters": {
|
|
"method": "POST",
|
|
"url": "=http://10.10.10.17:8123/api/template\n",
|
|
"authentication": "genericCredentialType",
|
|
"genericAuthType": "httpBearerAuth",
|
|
"sendHeaders": true,
|
|
"headerParameters": {
|
|
"parameters": [
|
|
{
|
|
"name": "Content-Type",
|
|
"value": "application/json"
|
|
},
|
|
{
|
|
"name": "Accept",
|
|
"value": "text/plain"
|
|
}
|
|
]
|
|
},
|
|
"sendBody": true,
|
|
"bodyParameters": {
|
|
"parameters": [
|
|
{
|
|
"name": "template",
|
|
"value": "{{ {\n \"soc_percent\": states(\"sensor.victron_battery_soc\"),\n \"battery_voltage_v\": states(\"sensor.victron_battery_voltage\"),\n \"battery_current_a\": states(\"sensor.victron_battery_current\"),\n \"pv_power_w\": states(\"sensor.victron_pv_power_system\"),\n \"edf_switch\": states(\"switch.edf_general_ok_switch\"),\n \"today_remaining_kwh\": states(\"sensor.energy_production_today_remaining\"),\n \"tomorrow_kwh\": states(\"sensor.energy_production_tomorrow\"),\n \"current_max_charge_current_a\": states(\"sensor.victron_max_charge_current_setting\"),\n \"current_max_charge_voltage_v\": states(\"sensor.victron_max_charge_voltage_setting\"),\n \"auto_enabled\": states(\"input_boolean.victron_auto_charge_enabled\"),\n \"night_takeover\": states(\"input_boolean.victron_evcs_night_grid_takeover_needed\"),\n \"night_target_soc\": states(\"input_number.victron_evcs_night_target_soc\"),\n \"house_ac_power_w\": states(\"sensor.victron_consumption_power_l1\"),\n \"grid_subscription_va\": states(\"input_number.victron_grid_subscription_va\"),\n \"grid_energy_needed_kwh\": states(\"input_number.evcs_balance_grid_energy_needed_kwh\"),\n \"notifications_enabled\": states(\"input_boolean.victron_auto_charge_notifications\"),\n \"last_signature\": states(\"input_text.victron_charge_last_signature\"),\n\n \"override_enabled\": states(\"input_boolean.victron_charge_override_enabled\"),\n \"override_profile\": states(\"input_select.victron_charge_override_profile\"),\n \"override_current_a\": states(\"input_number.victron_override_charge_current\"),\n \"override_voltage_v\": states(\"input_number.victron_override_charge_voltage\"),\n \"override_until\": states(\"input_datetime.victron_charge_override_until\"),\n \"override_reason\": states(\"input_text.victron_charge_override_reason\")\n} | tojson }}\n"
|
|
}
|
|
]
|
|
},
|
|
"options": {}
|
|
},
|
|
"id": "3aa1ccc7-0831-4c25-b511-e4fc76c0cc83",
|
|
"name": "HA Snapshot via Template",
|
|
"type": "n8n-nodes-base.httpRequest",
|
|
"typeVersion": 4.2,
|
|
"position": [
|
|
240,
|
|
0
|
|
],
|
|
"credentials": {
|
|
"httpBearerAuth": {
|
|
"id": "uv3sknYYigxBkaVN",
|
|
"name": "Bearer Auth account 2"
|
|
}
|
|
}
|
|
},
|
|
{
|
|
"parameters": {
|
|
"jsCode": "function num(v, fallback = NaN) {\n const n = Number.parseFloat(v);\n return Number.isFinite(n) ? n : fallback;\n}\n\nfunction low(v) {\n return (v ?? '').toString().trim().toLowerCase();\n}\n\nfunction parseMaybeJson(v) {\n if (typeof v !== 'string') return v;\n try {\n return JSON.parse(v);\n } catch {\n return v;\n }\n}\n\nfunction extractSnapshot(input) {\n if (typeof input === 'string') return parseMaybeJson(input);\n if (input?.data && typeof input.data === 'string') return parseMaybeJson(input.data);\n if (input?.body && typeof input.body === 'string') return parseMaybeJson(input.body);\n if (input?.data && typeof input.data === 'object') return input.data;\n if (input?.body && typeof input.body === 'object') return input.body;\n return input;\n}\n\nfunction round1(v) {\n return Math.round(v * 10) / 10;\n}\n\nfunction timeToMinutes(hh, mm) {\n return hh * 60 + mm;\n}\n\nfunction inRange(minNow, startMin, endMin) {\n return minNow >= startMin && minNow < endMin;\n}\n\nfunction getParisNowParts() {\n const fmt = new Intl.DateTimeFormat('fr-FR', {\n timeZone: 'Europe/Paris',\n year: 'numeric',\n month: '2-digit',\n day: '2-digit',\n hour: '2-digit',\n minute: '2-digit',\n second: '2-digit',\n hour12: false,\n });\n\n const parts = Object.fromEntries(\n fmt.formatToParts(new Date())\n .filter(p => p.type !== 'literal')\n .map(p => [p.type, p.value])\n );\n\n const date = `${parts.year}-${parts.month}-${parts.day}`;\n const localStamp = `${date} ${parts.hour}:${parts.minute}:${parts.second}`;\n\n return {\n year: Number(parts.year),\n month: Number(parts.month),\n day: Number(parts.day),\n hour: Number(parts.hour),\n minute: Number(parts.minute),\n second: Number(parts.second),\n date,\n localStamp,\n minNow: Number(parts.hour) * 60 + Number(parts.minute),\n };\n}\n\nfunction forecastBand(kwh) {\n if (!Number.isFinite(kwh)) return 'unknown';\n if (kwh >= 25) return 'sunny';\n if (kwh >= 12) return 'mixed';\n return 'dark';\n}\n\nconst cfg = {\n winterMonths: [11, 12, 1, 2],\n\n windows: {\n nightHC_start: timeToMinutes(1, 24),\n nightHC_end: timeToMinutes(7, 24),\n\n middayHC_start: timeToMinutes(12, 24),\n middayHC_end: timeToMinutes(14, 24),\n\n winterDay_start: timeToMinutes(7, 15),\n winterDay_end: timeToMinutes(16, 45),\n\n summerDay_start: timeToMinutes(7, 30),\n summerDay_end: timeToMinutes(19, 30),\n },\n\n profiles: {\n night_slow: { current_a: 30, voltage_v: 50.1 },\n takeover_hold: { current_a: 2, voltage_v: 50.1 },\n pv_boost: { current_a: 250, voltage_v: 51.5 },\n pv_mid: { current_a: 160, voltage_v: 51.5 },\n pv_topoff: { current_a: 80, voltage_v: 52.8 },\n pv_hold: { current_a: 30, voltage_v: 50.6 },\n midday_grid_catchup: { current_a: 30, voltage_v: 50.8 },\n emergency_rescue: { current_a: 60, voltage_v: 50.4 },\n },\n\n voltagePublishDelta: 0.05,\n currentPublishDelta: 0.5,\n\n mobileNotifyDomain: 'notify',\n mobileNotifyService: 'mobile_app_iphone_16_de_tt'\n};\n\nconst MQTT_TOPIC_CHARGE_CURRENT = 'W/c0619ab34ac5/settings/0/Settings/SystemSetup/MaxChargeCurrent';\nconst MQTT_TOPIC_CHARGE_VOLTAGE = 'W/c0619ab34ac5/settings/0/Settings/SystemSetup/MaxChargeVoltage';\n\nconst raw = $input.first().json;\nconst input = extractSnapshot(raw);\nconst now = getParisNowParts();\n\nconst soc = num(input.soc_percent, 0);\nconst batteryVoltageV = num(input.battery_voltage_v, NaN);\nconst batteryCurrentA = num(input.battery_current_a, NaN);\nconst pvPowerW = num(input.pv_power_w, 0);\nconst edfSwitch = low(input.edf_switch || 'off') === 'on' ? 'on' : 'off';\n\nconst todayRemainingKwh = num(input.today_remaining_kwh, 0);\nconst tomorrowKwh = num(input.tomorrow_kwh, 0);\n\nconst currentMaxChargeCurrentA = num(input.current_max_charge_current_a, 0);\nconst currentMaxChargeVoltageV = num(input.current_max_charge_voltage_v, 0);\n\nconst autoEnabled = low(input.auto_enabled || 'off') === 'on';\nconst nightTakeover = low(input.night_takeover || 'off') === 'on';\nconst nightTargetSoc = num(input.night_target_soc, 35);\n// COURANT CALCULE (07/10/2026) : entrees de la recharge reseau HC.\nconst houseAcPowerW = num(input.house_ac_power_w, NaN);\nconst gridSubscriptionVa = num(input.grid_subscription_va, NaN);\nconst gridEnergyNeededKwh = num(input.grid_energy_needed_kwh, NaN);\nconst notificationsEnabled = low(input.notifications_enabled || 'off') === 'on';\nconst lastSignature = (input.last_signature ?? '').toString().trim();\n\nconst overrideEnabled = low(input.override_enabled || 'off') === 'on';\nconst overrideProfile = low(input.override_profile || 'auto');\nconst overrideCurrentA = num(input.override_current_a, NaN);\nconst overrideVoltageV = num(input.override_voltage_v, NaN);\nconst overrideUntil = (input.override_until ?? '').toString().trim();\nconst overrideReason = (input.override_reason ?? '').toString().trim();\n\nconst isWinter = cfg.winterMonths.includes(now.month);\nconst inNightHC = inRange(now.minNow, cfg.windows.nightHC_start, cfg.windows.nightHC_end);\nconst inMiddayHC = inRange(now.minNow, cfg.windows.middayHC_start, cfg.windows.middayHC_end);\nconst inDayWindow = isWinter\n ? inRange(now.minNow, cfg.windows.winterDay_start, cfg.windows.winterDay_end)\n : inRange(now.minNow, cfg.windows.summerDay_start, cfg.windows.summerDay_end);\n\nconst forecastRefKwh = now.hour < 8 ? Math.max(todayRemainingKwh, tomorrowKwh, 0) : todayRemainingKwh;\nconst forecastState = forecastBand(forecastRefKwh);\n\nfunction profileValues(profileName) {\n if (profileName === 'manual') {\n return {\n current_a: Number.isFinite(overrideCurrentA) ? overrideCurrentA : cfg.profiles.pv_boost.current_a,\n voltage_v: Number.isFinite(overrideVoltageV) ? overrideVoltageV : cfg.profiles.pv_boost.voltage_v,\n };\n }\n return cfg.profiles[profileName] || null;\n}\n\nconst overrideActive =\n overrideEnabled &&\n overrideProfile !== 'auto' &&\n /^\\d{4}-\\d{2}-\\d{2}/.test(overrideUntil) &&\n now.localStamp < overrideUntil;\n\nlet mode = 'idle';\nlet effectiveProfile = 'auto_idle';\nlet targetCurrentA = currentMaxChargeCurrentA || 30;\nlet targetVoltageV = currentMaxChargeVoltageV || 50.5;\nlet criticalAlert = false;\nlet reason = [];\n\nif (!autoEnabled) {\n mode = 'automation_disabled';\n effectiveProfile = 'manual_keep_current';\n targetCurrentA = currentMaxChargeCurrentA || 30;\n targetVoltageV = currentMaxChargeVoltageV || 50.5;\n reason.push(\"Automatisation désactivée, conservation des réglages actuels\");\n} else {\n if (soc < 20 && !inNightHC && !inMiddayHC) {\n mode = 'emergency_rescue';\n effectiveProfile = 'emergency_rescue';\n targetCurrentA = cfg.profiles.emergency_rescue.current_a;\n targetVoltageV = cfg.profiles.emergency_rescue.voltage_v;\n criticalAlert = true;\n reason.push(`SOC critique ${soc}%`);\n }\n\n // P4 : takeover EVCS nocturne. EDF est ON pour la maison + le VE (HC),\n // la batterie doit seulement être RAMENÉE à la cible matin puis MAINTENUE,\n // pas rechargée à fond (cible adaptée au forecast : été ~35%, hiver ~85%).\n else if (nightTakeover && edfSwitch === 'on') {\n const holdTargetSoc = Math.min(95, Math.max(20, nightTargetSoc));\n if (soc < holdTargetSoc - 1) {\n mode = 'evcs_takeover_recover';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n // COURANT CALCULE (07/10/2026) : energie a reprendre (bilan, sinon SOC x\n // 0,30 kWh/point mesure le 20/09) / temps restant dans la fenetre HC, +15 %\n // de marge ; borne bas 10 A, haut = min(chargeur des 2 MultiPlus 140 A,\n // (90 % de l'abonnement - maison) / tension). Recalcule a chaque cycle :\n // il suit la maison et rattrape le retard en fin de fenetre.\n const fin = inMiddayHC ? cfg.windows.middayHC_end : (inNightHC ? cfg.windows.nightHC_end : null);\n const restantH = fin === null ? null : Math.max(0.25, ((fin - now.minNow + 1440) % 1440) / 60);\n const energieKwh = Number.isFinite(gridEnergyNeededKwh) && gridEnergyNeededKwh > 0\n ? gridEnergyNeededKwh : Math.max(0, holdTargetSoc - soc) * 0.30;\n const tensionV = Number.isFinite(batteryVoltageV) && batteryVoltageV > 40 ? batteryVoltageV : 51;\n if (restantH !== null && energieKwh > 0) {\n const besoinA = energieKwh * 1000 / restantH / tensionV * 1.15;\n // PLAFOND SOLAIRE (08/10/2026) : le solaire (MPPT, courant continu) charge\n // la batterie en plus de ce que l'entree reseau laisse libre.\n const reseauLibreW = Number.isFinite(gridSubscriptionVa) && Number.isFinite(houseAcPowerW)\n ? gridSubscriptionVa * 0.9 - houseAcPowerW + Math.max(0, pvPowerW) : NaN;\n const plafondA = Math.min(140, Number.isFinite(reseauLibreW) ? Math.max(0, reseauLibreW / tensionV) : 140);\n targetCurrentA = Math.round(Math.max(10, Math.min(plafondA, Math.ceil(besoinA / 5) * 5)) * 10) / 10;\n // TENSION DE RECHARGE (09/10/2026) : 50,1 V (night_slow) bride le courant des que\n // la batterie depasse ~50 % ; on charge a la tension solaire normale.\n targetVoltageV = cfg.profiles.pv_mid.voltage_v;\n reason.push(`Recharge reseau HC : ${round1(energieKwh)} kWh en ${round1(restantH)} h -> ${targetCurrentA} A`\n + (Number.isFinite(reseauLibreW) ? ` (abonnement + solaire : ${Math.round(reseauLibreW)} W libres)` : ''));\n }\n reason.push(`Takeover EVCS : recharge vers cible matin ${holdTargetSoc}% (SOC ${soc}%)`);\n } else {\n mode = 'evcs_takeover_hold';\n effectiveProfile = 'takeover_hold';\n targetCurrentA = cfg.profiles.takeover_hold.current_a;\n targetVoltageV = cfg.profiles.takeover_hold.voltage_v;\n reason.push(`Takeover EVCS : maintien SOC ~${holdTargetSoc}% (maison+VE sur HC, batterie en pause)`);\n }\n }\n\n else if (isWinter && inNightHC) {\n let targetSoc;\n if (forecastState === 'sunny') targetSoc = 40;\n else if (forecastState === 'mixed') targetSoc = 60;\n else targetSoc = 80;\n\n if (soc < targetSoc - 1) {\n mode = 'winter_night_charge_window';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n reason.push(`Hiver HC nuit, cible SOC ${targetSoc}% selon forecast ${forecastState}`);\n } else {\n mode = 'winter_night_idle';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n reason.push(`Hiver HC nuit, SOC ${soc}% déjà suffisant`);\n }\n }\n\n else if (!isWinter && inNightHC) {\n if (soc < 22) {\n mode = 'summer_night_rescue_window';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n reason.push(\"Été HC nuit, secours SOC < 22%\");\n } else {\n mode = 'summer_night_idle';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n reason.push(\"Été HC nuit, pas de besoin réseau\");\n }\n }\n\n else if (\n inMiddayHC &&\n soc < 85 &&\n forecastRefKwh < 8 &&\n pvPowerW < 1500\n ) {\n mode = 'midday_catchup_window';\n effectiveProfile = 'midday_grid_catchup';\n targetCurrentA = cfg.profiles.midday_grid_catchup.current_a;\n targetVoltageV = cfg.profiles.midday_grid_catchup.voltage_v;\n reason.push(`HC midi rattrapage : SOC ${soc}% | forecast ${forecastRefKwh} kWh | PV ${pvPowerW} W`);\n }\n\n else if (inDayWindow) {\n if (soc < 80) {\n mode = 'day_pv_boost';\n effectiveProfile = 'pv_boost';\n targetCurrentA = cfg.profiles.pv_boost.current_a;\n targetVoltageV = cfg.profiles.pv_boost.voltage_v;\n reason.push(`Jour SOC bas ${soc}% : capture PV max`);\n } else if (soc < 90) {\n mode = 'day_pv_mid';\n effectiveProfile = 'pv_mid';\n targetCurrentA = cfg.profiles.pv_mid.current_a;\n targetVoltageV = cfg.profiles.pv_mid.voltage_v;\n reason.push(`Jour SOC intermédiaire ${soc}%`);\n } else if (soc < 95) {\n mode = 'day_pv_topoff';\n effectiveProfile = 'pv_topoff';\n targetCurrentA = cfg.profiles.pv_topoff.current_a;\n targetVoltageV = cfg.profiles.pv_topoff.voltage_v;\n reason.push(`Jour top-off vers 95% | SOC ${soc}%`);\n } else {\n mode = 'day_pv_hold';\n effectiveProfile = 'pv_hold';\n targetCurrentA = cfg.profiles.pv_hold.current_a;\n targetVoltageV = cfg.profiles.pv_hold.voltage_v;\n reason.push(`Jour maintien haut SOC ${soc}%`);\n }\n\n if (\n Number.isFinite(batteryVoltageV) &&\n soc < 95 &&\n pvPowerW > 2000 &&\n batteryVoltageV >= (targetVoltageV - 0.15)\n ) {\n targetVoltageV = Math.max(targetVoltageV, 51.3);\n targetCurrentA = Math.max(targetCurrentA, 80);\n if (soc >= 90) {\n effectiveProfile = 'pv_topoff';\n mode = 'day_pv_topoff';\n } else {\n effectiveProfile = 'pv_boost';\n }\n reason.push(`Batterie proche consigne (${round1(batteryVoltageV)}V), relèvement anti-bridage`);\n }\n\n if (\n Number.isFinite(batteryCurrentA) &&\n soc < 95 &&\n pvPowerW > 6000 &&\n batteryCurrentA >= (targetCurrentA - 3)\n ) {\n targetCurrentA = Math.max(targetCurrentA,\n // Valeurs de la table, et non des constantes qui prennent du retard.\n // ⚠️ Ce Math.max est un NO-OP : le plafond du profil est au-dessus du\n // plancher dans toutes les bandes. Constate le 14/09/2026 ; le\n // mecanisme n'a pas ete ranime deliberement (un plafond qui se releve\n // parce qu'on bute dessus est une boucle de retroaction).\n soc >= 90 ? cfg.profiles.pv_topoff.current_a : cfg.profiles.pv_mid.current_a);\n reason.push(`Courant batterie proche limite (${round1(batteryCurrentA)}A), relèvement du plafond`);\n }\n }\n\n\n else {\n mode = 'off_window_idle';\n effectiveProfile = 'pv_hold';\n targetCurrentA = cfg.profiles.pv_hold.current_a;\n targetVoltageV = cfg.profiles.pv_hold.voltage_v;\n reason.push(\"Hors fenêtre utile\");\n }\n}\n\nif (overrideActive) {\n const ov = profileValues(overrideProfile);\n if (ov) {\n targetCurrentA = ov.current_a;\n targetVoltageV = ov.voltage_v;\n effectiveProfile = `override_${overrideProfile}`;\n mode = `${mode}_override`;\n reason.unshift(\n `Override actif jusqu'à ${overrideUntil} | profil=${overrideProfile}` +\n (overrideReason ? ` | ${overrideReason}` : '')\n );\n }\n} else if (overrideEnabled && overrideProfile !== 'auto') {\n reason.push(\"Override configuré mais inactif ou expiré\");\n}\n\ntargetCurrentA = round1(targetCurrentA);\ntargetVoltageV = round1(targetVoltageV);\n\nconst shouldPublishCurrent =\n !Number.isFinite(currentMaxChargeCurrentA) ||\n Math.abs(targetCurrentA - currentMaxChargeCurrentA) >= cfg.currentPublishDelta;\n\nconst shouldPublishVoltage =\n !Number.isFinite(currentMaxChargeVoltageV) ||\n Math.abs(targetVoltageV - currentMaxChargeVoltageV) >= cfg.voltagePublishDelta;\n\nconst shortReason = reason.join(' | ').slice(0, 255);\n\nconst signature = [\n now.date,\n mode,\n effectiveProfile,\n `i=${targetCurrentA}`,\n `v=${targetVoltageV}`\n].join('|');\n\nconst signatureChanged = signature !== lastSignature;\n\nconst result = {\n timestamp_paris: now.localStamp,\n\n inputs: {\n soc_percent: soc,\n battery_voltage_v: Number.isFinite(batteryVoltageV) ? batteryVoltageV : null,\n battery_current_a: Number.isFinite(batteryCurrentA) ? batteryCurrentA : null,\n pv_power_w: pvPowerW,\n edf_switch_observed: edfSwitch,\n today_remaining_kwh: todayRemainingKwh,\n tomorrow_kwh: tomorrowKwh,\n current_max_charge_current_a: currentMaxChargeCurrentA,\n current_max_charge_voltage_v: currentMaxChargeVoltageV,\n auto_enabled: autoEnabled,\n notifications_enabled: notificationsEnabled,\n last_signature: lastSignature || null,\n\n override_enabled: overrideEnabled,\n override_profile: overrideProfile,\n override_current_a: Number.isFinite(overrideCurrentA) ? overrideCurrentA : null,\n override_voltage_v: Number.isFinite(overrideVoltageV) ? overrideVoltageV : null,\n override_until: overrideUntil || null,\n override_reason: overrideReason || null\n },\n\n computed: {\n is_winter: isWinter,\n in_night_hc: inNightHC,\n in_midday_hc: inMiddayHC,\n in_day_window: inDayWindow,\n forecast_reference_kwh: round1(forecastRefKwh),\n forecast_state: forecastState,\n override_active: overrideActive\n },\n\n decision: {\n mode,\n effective_profile: effectiveProfile,\n target_current_a: targetCurrentA,\n target_voltage_v: targetVoltageV,\n should_publish_current: shouldPublishCurrent,\n should_publish_voltage: shouldPublishVoltage,\n critical_alert: criticalAlert,\n signature,\n signature_changed: signatureChanged,\n reason,\n short_reason: shortReason\n },\n\n ha_service_calls: {\n helper_current: {\n domain: 'input_number',\n service: 'set_value',\n data: {\n entity_id: 'input_number.victron_target_charge_current',\n value: targetCurrentA\n }\n },\n\n helper_voltage: {\n domain: 'input_number',\n service: 'set_value',\n data: {\n entity_id: 'input_number.victron_target_charge_voltage',\n value: targetVoltageV\n }\n },\n\n helper_soc_live: {\n domain: 'input_number',\n service: 'set_value',\n data: {\n entity_id: 'input_number.victron_soc_live',\n value: soc\n }\n },\n\n helper_mode: {\n domain: 'input_text',\n service: 'set_value',\n data: {\n entity_id: 'input_text.victron_charge_mode',\n value: mode\n }\n },\n\n helper_reason: {\n domain: 'input_text',\n service: 'set_value',\n data: {\n entity_id: 'input_text.victron_charge_reason',\n value: shortReason || 'Aucune raison'\n }\n },\n\n helper_profile: {\n domain: 'input_text',\n service: 'set_value',\n data: {\n entity_id: 'input_text.victron_effective_charge_profile',\n value: effectiveProfile\n }\n },\n\n helper_signature: {\n domain: 'input_text',\n service: 'set_value',\n data: {\n entity_id: 'input_text.victron_charge_last_signature',\n value: signature\n }\n },\n\n mqtt_current: {\n domain: 'mqtt',\n service: 'publish',\n data: {\n topic: MQTT_TOPIC_CHARGE_CURRENT,\n payload: JSON.stringify({ value: targetCurrentA }),\n retain: false\n }\n },\n\n mqtt_voltage: {\n domain: 'mqtt',\n service: 'publish',\n data: {\n topic: MQTT_TOPIC_CHARGE_VOLTAGE,\n payload: JSON.stringify({ value: targetVoltageV }),\n retain: false\n }\n },\n\n logbook: {\n domain: 'logbook',\n service: 'log',\n data: {\n name: 'Victron Auto Charge',\n message: `${mode} | profile=${effectiveProfile} | I=${targetCurrentA}A | V=${targetVoltageV}V | SOC=${soc}% | ${shortReason}`,\n entity_id: 'sensor.victron_battery_soc'\n }\n },\n\n mobile_notification: {\n domain: cfg.mobileNotifyDomain,\n service: cfg.mobileNotifyService,\n data: {\n title: 'Victron Auto Charge',\n message: `${mode} | profile=${effectiveProfile} | I=${targetCurrentA}A | V=${targetVoltageV}V | SOC=${soc}%`,\n data: {\n push: {\n \"interruption-level\": \"time-sensitive\",\n sound: { name: \"default\" }\n },\n ttl: 0,\n priority: \"high\"\n }\n }\n }\n }\n};\n\nreturn [{ json: result }];\n"
|
|
},
|
|
"id": "a98c5bda-cf34-447e-942e-37ae75a45d5c",
|
|
"name": "Compute Charge Targets",
|
|
"type": "n8n-nodes-base.code",
|
|
"typeVersion": 2,
|
|
"position": [
|
|
512,
|
|
0
|
|
]
|
|
},
|
|
{
|
|
"parameters": {
|
|
"jsCode": "const root = $input.first().json;\nconst actions = [];\n\n// Helpers : toujours mis à jour\nactions.push({\n json: {\n action: 'helper_mode',\n ...root.ha_service_calls.helper_mode\n }\n});\n\nactions.push({\n json: {\n action: 'helper_reason',\n ...root.ha_service_calls.helper_reason\n }\n});\n\nactions.push({\n json: {\n action: 'helper_current',\n ...root.ha_service_calls.helper_current\n }\n});\n\nactions.push({\n json: {\n action: 'helper_voltage',\n ...root.ha_service_calls.helper_voltage\n }\n});\n\nactions.push({\n json: {\n action: 'helper_soc_live',\n ...root.ha_service_calls.helper_soc_live\n }\n});\n\nif (root.ha_service_calls.helper_profile) {\n actions.push({\n json: {\n action: 'helper_profile',\n ...root.ha_service_calls.helper_profile\n }\n });\n}\n\n// Signature + log seulement si changement réel\nif (root.decision.signature_changed) {\n actions.push({\n json: {\n action: 'helper_signature',\n ...root.ha_service_calls.helper_signature\n }\n });\n\n actions.push({\n json: {\n action: 'logbook',\n ...root.ha_service_calls.logbook\n }\n });\n}\n\n// D'abord les limites Victron\nif (root.decision.should_publish_current) {\n actions.push({\n json: {\n action: 'mqtt_current',\n ...root.ha_service_calls.mqtt_current\n }\n });\n}\n\nif (root.decision.should_publish_voltage) {\n actions.push({\n json: {\n action: 'mqtt_voltage',\n ...root.ha_service_calls.mqtt_voltage\n }\n });\n}\n\n// Notification iPhone seulement si critique + activée\nif (root.inputs.notifications_enabled && root.decision.critical_alert) {\n actions.push({\n json: {\n action: 'mobile_notification',\n ...root.ha_service_calls.mobile_notification\n }\n });\n}\n\nreturn actions;\n"
|
|
},
|
|
"id": "d0a3ecb8-6c4d-46e6-a81c-cb84a789b0d7",
|
|
"name": "Build HA Service Actions",
|
|
"type": "n8n-nodes-base.code",
|
|
"typeVersion": 2,
|
|
"position": [
|
|
768,
|
|
0
|
|
]
|
|
},
|
|
{
|
|
"parameters": {
|
|
"method": "POST",
|
|
"url": "={{ 'http://10.10.10.17:8123/api/services/' + $json.domain + '/' + $json.service }}\n",
|
|
"authentication": "genericCredentialType",
|
|
"genericAuthType": "httpBearerAuth",
|
|
"sendHeaders": true,
|
|
"headerParameters": {
|
|
"parameters": [
|
|
{
|
|
"name": "Content-Type",
|
|
"value": "application/json"
|
|
},
|
|
{
|
|
"name": "accept",
|
|
"value": "application/json"
|
|
}
|
|
]
|
|
},
|
|
"sendBody": true,
|
|
"specifyBody": "json",
|
|
"jsonBody": "={{ $json.data }}",
|
|
"options": {}
|
|
},
|
|
"id": "88eb5cba-7ecb-4fca-a995-fd8612118f3a",
|
|
"name": "Execute HA Service",
|
|
"type": "n8n-nodes-base.httpRequest",
|
|
"typeVersion": 4.2,
|
|
"position": [
|
|
1040,
|
|
0
|
|
],
|
|
"alwaysOutputData": true,
|
|
"credentials": {
|
|
"httpBearerAuth": {
|
|
"id": "uv3sknYYigxBkaVN",
|
|
"name": "Bearer Auth account 2"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"connections": {
|
|
"Schedule Trigger": {
|
|
"main": [
|
|
[
|
|
{
|
|
"node": "HA Snapshot via Template",
|
|
"type": "main",
|
|
"index": 0
|
|
}
|
|
]
|
|
]
|
|
},
|
|
"HA Snapshot via Template": {
|
|
"main": [
|
|
[
|
|
{
|
|
"node": "Compute Charge Targets",
|
|
"type": "main",
|
|
"index": 0
|
|
}
|
|
]
|
|
]
|
|
},
|
|
"Compute Charge Targets": {
|
|
"main": [
|
|
[
|
|
{
|
|
"node": "Build HA Service Actions",
|
|
"type": "main",
|
|
"index": 0
|
|
}
|
|
]
|
|
]
|
|
},
|
|
"Build HA Service Actions": {
|
|
"main": [
|
|
[
|
|
{
|
|
"node": "Execute HA Service",
|
|
"type": "main",
|
|
"index": 0
|
|
}
|
|
]
|
|
]
|
|
}
|
|
},
|
|
"settings": {
|
|
"executionOrder": "v1",
|
|
"binaryMode": "separate",
|
|
"availableInMCP": true,
|
|
"timeSavedMode": "fixed",
|
|
"callerPolicy": "workflowsFromSameOwner",
|
|
"saveDataErrorExecution": "all"
|
|
},
|
|
"staticData": {
|
|
"node:Schedule Trigger": {
|
|
"recurrenceRules": [
|
|
null
|
|
],
|
|
"recurrenceRuleSignatures": [
|
|
null
|
|
]
|
|
}
|
|
},
|
|
"meta": null,
|
|
"nodeGroups": [],
|
|
"pinData": {},
|
|
"versionId": "de4ce3dd-bda2-4d27-ba39-72cfc4cfbcbb",
|
|
"activeVersionId": "de4ce3dd-bda2-4d27-ba39-72cfc4cfbcbb",
|
|
"versionCounter": 180,
|
|
"triggerCount": 1,
|
|
"sourceWorkflowId": null,
|
|
"shared": [
|
|
{
|
|
"updatedAt": "2026-03-13T01:18:19.440Z",
|
|
"createdAt": "2026-03-13T01:18:19.440Z",
|
|
"role": "workflow:owner",
|
|
"workflowId": "cTeeHy4ePiVeELLh",
|
|
"projectId": "1q2yd8IyTc8fb25V",
|
|
"project": {
|
|
"updatedAt": "2026-02-06T16:27:24.469Z",
|
|
"createdAt": "2026-02-06T16:23:40.444Z",
|
|
"id": "1q2yd8IyTc8fb25V",
|
|
"name": "thierry tallagrand <tallagrand.thierry@gmail.com>",
|
|
"type": "personal",
|
|
"icon": null,
|
|
"description": null,
|
|
"customTelemetryTags": [],
|
|
"creatorId": "8b9e9552-cd74-4863-82a3-174b3b3befa2"
|
|
}
|
|
}
|
|
],
|
|
"tags": [],
|
|
"activeVersion": {
|
|
"updatedAt": "2026-07-09T16:18:50.134Z",
|
|
"createdAt": "2026-07-09T16:18:50.134Z",
|
|
"versionId": "de4ce3dd-bda2-4d27-ba39-72cfc4cfbcbb",
|
|
"workflowId": "cTeeHy4ePiVeELLh",
|
|
"nodes": [
|
|
{
|
|
"parameters": {
|
|
"rule": {
|
|
"interval": [
|
|
{
|
|
"field": "minutes"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"id": "3bc36d27-0e92-4207-bbde-7f23efbc1881",
|
|
"name": "Schedule Trigger",
|
|
"type": "n8n-nodes-base.scheduleTrigger",
|
|
"typeVersion": 1.2,
|
|
"position": [
|
|
0,
|
|
0
|
|
]
|
|
},
|
|
{
|
|
"parameters": {
|
|
"method": "POST",
|
|
"url": "=http://10.10.10.17:8123/api/template\n",
|
|
"authentication": "genericCredentialType",
|
|
"genericAuthType": "httpBearerAuth",
|
|
"sendHeaders": true,
|
|
"headerParameters": {
|
|
"parameters": [
|
|
{
|
|
"name": "Content-Type",
|
|
"value": "application/json"
|
|
},
|
|
{
|
|
"name": "Accept",
|
|
"value": "text/plain"
|
|
}
|
|
]
|
|
},
|
|
"sendBody": true,
|
|
"bodyParameters": {
|
|
"parameters": [
|
|
{
|
|
"name": "template",
|
|
"value": "{{ {\n \"soc_percent\": states(\"sensor.victron_battery_soc\"),\n \"battery_voltage_v\": states(\"sensor.victron_battery_voltage\"),\n \"battery_current_a\": states(\"sensor.victron_battery_current\"),\n \"pv_power_w\": states(\"sensor.victron_pv_power_system\"),\n \"edf_switch\": states(\"switch.edf_general_ok_switch\"),\n \"today_remaining_kwh\": states(\"sensor.energy_production_today_remaining\"),\n \"tomorrow_kwh\": states(\"sensor.energy_production_tomorrow\"),\n \"current_max_charge_current_a\": states(\"sensor.victron_max_charge_current_setting\"),\n \"current_max_charge_voltage_v\": states(\"sensor.victron_max_charge_voltage_setting\"),\n \"auto_enabled\": states(\"input_boolean.victron_auto_charge_enabled\"),\n \"night_takeover\": states(\"input_boolean.victron_evcs_night_grid_takeover_needed\"),\n \"night_target_soc\": states(\"input_number.victron_evcs_night_target_soc\"),\n \"notifications_enabled\": states(\"input_boolean.victron_auto_charge_notifications\"),\n \"last_signature\": states(\"input_text.victron_charge_last_signature\"),\n\n \"override_enabled\": states(\"input_boolean.victron_charge_override_enabled\"),\n \"override_profile\": states(\"input_select.victron_charge_override_profile\"),\n \"override_current_a\": states(\"input_number.victron_override_charge_current\"),\n \"override_voltage_v\": states(\"input_number.victron_override_charge_voltage\"),\n \"override_until\": states(\"input_datetime.victron_charge_override_until\"),\n \"override_reason\": states(\"input_text.victron_charge_override_reason\")\n} | tojson }}\n"
|
|
}
|
|
]
|
|
},
|
|
"options": {}
|
|
},
|
|
"id": "3aa1ccc7-0831-4c25-b511-e4fc76c0cc83",
|
|
"name": "HA Snapshot via Template",
|
|
"type": "n8n-nodes-base.httpRequest",
|
|
"typeVersion": 4.2,
|
|
"position": [
|
|
240,
|
|
0
|
|
],
|
|
"credentials": {
|
|
"httpBearerAuth": {
|
|
"id": "uv3sknYYigxBkaVN",
|
|
"name": "Bearer Auth account 2"
|
|
}
|
|
}
|
|
},
|
|
{
|
|
"parameters": {
|
|
"jsCode": "function num(v, fallback = NaN) {\n const n = Number.parseFloat(v);\n return Number.isFinite(n) ? n : fallback;\n}\n\nfunction low(v) {\n return (v ?? '').toString().trim().toLowerCase();\n}\n\nfunction parseMaybeJson(v) {\n if (typeof v !== 'string') return v;\n try {\n return JSON.parse(v);\n } catch {\n return v;\n }\n}\n\nfunction extractSnapshot(input) {\n if (typeof input === 'string') return parseMaybeJson(input);\n if (input?.data && typeof input.data === 'string') return parseMaybeJson(input.data);\n if (input?.body && typeof input.body === 'string') return parseMaybeJson(input.body);\n if (input?.data && typeof input.data === 'object') return input.data;\n if (input?.body && typeof input.body === 'object') return input.body;\n return input;\n}\n\nfunction round1(v) {\n return Math.round(v * 10) / 10;\n}\n\nfunction timeToMinutes(hh, mm) {\n return hh * 60 + mm;\n}\n\nfunction inRange(minNow, startMin, endMin) {\n return minNow >= startMin && minNow < endMin;\n}\n\nfunction getParisNowParts() {\n const fmt = new Intl.DateTimeFormat('fr-FR', {\n timeZone: 'Europe/Paris',\n year: 'numeric',\n month: '2-digit',\n day: '2-digit',\n hour: '2-digit',\n minute: '2-digit',\n second: '2-digit',\n hour12: false,\n });\n\n const parts = Object.fromEntries(\n fmt.formatToParts(new Date())\n .filter(p => p.type !== 'literal')\n .map(p => [p.type, p.value])\n );\n\n const date = `${parts.year}-${parts.month}-${parts.day}`;\n const localStamp = `${date} ${parts.hour}:${parts.minute}:${parts.second}`;\n\n return {\n year: Number(parts.year),\n month: Number(parts.month),\n day: Number(parts.day),\n hour: Number(parts.hour),\n minute: Number(parts.minute),\n second: Number(parts.second),\n date,\n localStamp,\n minNow: Number(parts.hour) * 60 + Number(parts.minute),\n };\n}\n\nfunction forecastBand(kwh) {\n if (!Number.isFinite(kwh)) return 'unknown';\n if (kwh >= 25) return 'sunny';\n if (kwh >= 12) return 'mixed';\n return 'dark';\n}\n\nconst cfg = {\n winterMonths: [11, 12, 1, 2],\n\n windows: {\n nightHC_start: timeToMinutes(1, 24),\n nightHC_end: timeToMinutes(7, 24),\n\n middayHC_start: timeToMinutes(12, 24),\n middayHC_end: timeToMinutes(14, 24),\n\n winterDay_start: timeToMinutes(7, 15),\n winterDay_end: timeToMinutes(16, 45),\n\n summerDay_start: timeToMinutes(7, 30),\n summerDay_end: timeToMinutes(19, 30),\n },\n\n profiles: {\n night_slow: { current_a: 30, voltage_v: 50.1 },\n takeover_hold: { current_a: 2, voltage_v: 50.1 },\n pv_boost: { current_a: 130, voltage_v: 51.5 },\n pv_mid: { current_a: 110, voltage_v: 51.2 },\n pv_topoff: { current_a: 80, voltage_v: 51.3 },\n pv_hold: { current_a: 30, voltage_v: 50.6 },\n midday_grid_catchup: { current_a: 30, voltage_v: 50.8 },\n emergency_rescue: { current_a: 60, voltage_v: 50.4 },\n },\n\n voltagePublishDelta: 0.05,\n currentPublishDelta: 0.5,\n\n mobileNotifyDomain: 'notify',\n mobileNotifyService: 'mobile_app_iphone_16_de_tt'\n};\n\nconst MQTT_TOPIC_CHARGE_CURRENT = 'W/c0619ab34ac5/settings/0/Settings/SystemSetup/MaxChargeCurrent';\nconst MQTT_TOPIC_CHARGE_VOLTAGE = 'W/c0619ab34ac5/settings/0/Settings/SystemSetup/MaxChargeVoltage';\n\nconst raw = $input.first().json;\nconst input = extractSnapshot(raw);\nconst now = getParisNowParts();\n\nconst soc = num(input.soc_percent, 0);\nconst batteryVoltageV = num(input.battery_voltage_v, NaN);\nconst batteryCurrentA = num(input.battery_current_a, NaN);\nconst pvPowerW = num(input.pv_power_w, 0);\nconst edfSwitch = low(input.edf_switch || 'off') === 'on' ? 'on' : 'off';\n\nconst todayRemainingKwh = num(input.today_remaining_kwh, 0);\nconst tomorrowKwh = num(input.tomorrow_kwh, 0);\n\nconst currentMaxChargeCurrentA = num(input.current_max_charge_current_a, 0);\nconst currentMaxChargeVoltageV = num(input.current_max_charge_voltage_v, 0);\n\nconst autoEnabled = low(input.auto_enabled || 'off') === 'on';\nconst nightTakeover = low(input.night_takeover || 'off') === 'on';\nconst nightTargetSoc = num(input.night_target_soc, 35);\nconst notificationsEnabled = low(input.notifications_enabled || 'off') === 'on';\nconst lastSignature = (input.last_signature ?? '').toString().trim();\n\nconst overrideEnabled = low(input.override_enabled || 'off') === 'on';\nconst overrideProfile = low(input.override_profile || 'auto');\nconst overrideCurrentA = num(input.override_current_a, NaN);\nconst overrideVoltageV = num(input.override_voltage_v, NaN);\nconst overrideUntil = (input.override_until ?? '').toString().trim();\nconst overrideReason = (input.override_reason ?? '').toString().trim();\n\nconst isWinter = cfg.winterMonths.includes(now.month);\nconst inNightHC = inRange(now.minNow, cfg.windows.nightHC_start, cfg.windows.nightHC_end);\nconst inMiddayHC = inRange(now.minNow, cfg.windows.middayHC_start, cfg.windows.middayHC_end);\nconst inDayWindow = isWinter\n ? inRange(now.minNow, cfg.windows.winterDay_start, cfg.windows.winterDay_end)\n : inRange(now.minNow, cfg.windows.summerDay_start, cfg.windows.summerDay_end);\n\nconst forecastRefKwh = now.hour < 8 ? Math.max(todayRemainingKwh, tomorrowKwh, 0) : todayRemainingKwh;\nconst forecastState = forecastBand(forecastRefKwh);\n\nfunction profileValues(profileName) {\n if (profileName === 'manual') {\n return {\n current_a: Number.isFinite(overrideCurrentA) ? overrideCurrentA : cfg.profiles.pv_boost.current_a,\n voltage_v: Number.isFinite(overrideVoltageV) ? overrideVoltageV : cfg.profiles.pv_boost.voltage_v,\n };\n }\n return cfg.profiles[profileName] || null;\n}\n\nconst overrideActive =\n overrideEnabled &&\n overrideProfile !== 'auto' &&\n /^\\d{4}-\\d{2}-\\d{2}/.test(overrideUntil) &&\n now.localStamp < overrideUntil;\n\nlet mode = 'idle';\nlet effectiveProfile = 'auto_idle';\nlet targetCurrentA = currentMaxChargeCurrentA || 30;\nlet targetVoltageV = currentMaxChargeVoltageV || 50.5;\nlet criticalAlert = false;\nlet reason = [];\n\nif (!autoEnabled) {\n mode = 'automation_disabled';\n effectiveProfile = 'manual_keep_current';\n targetCurrentA = currentMaxChargeCurrentA || 30;\n targetVoltageV = currentMaxChargeVoltageV || 50.5;\n reason.push(\"Automatisation désactivée, conservation des réglages actuels\");\n} else {\n if (soc < 20 && !inNightHC && !inMiddayHC) {\n mode = 'emergency_rescue';\n effectiveProfile = 'emergency_rescue';\n targetCurrentA = cfg.profiles.emergency_rescue.current_a;\n targetVoltageV = cfg.profiles.emergency_rescue.voltage_v;\n criticalAlert = true;\n reason.push(`SOC critique ${soc}%`);\n }\n\n // P4 : takeover EVCS nocturne. EDF est ON pour la maison + le VE (HC),\n // la batterie doit seulement être RAMENÉE à la cible matin puis MAINTENUE,\n // pas rechargée à fond (cible adaptée au forecast : été ~35%, hiver ~85%).\n else if (nightTakeover && edfSwitch === 'on') {\n const holdTargetSoc = Math.min(95, Math.max(20, nightTargetSoc));\n if (soc < holdTargetSoc - 1) {\n mode = 'evcs_takeover_recover';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n reason.push(`Takeover EVCS : recharge vers cible matin ${holdTargetSoc}% (SOC ${soc}%)`);\n } else {\n mode = 'evcs_takeover_hold';\n effectiveProfile = 'takeover_hold';\n targetCurrentA = cfg.profiles.takeover_hold.current_a;\n targetVoltageV = cfg.profiles.takeover_hold.voltage_v;\n reason.push(`Takeover EVCS : maintien SOC ~${holdTargetSoc}% (maison+VE sur HC, batterie en pause)`);\n }\n }\n\n else if (isWinter && inNightHC) {\n let targetSoc;\n if (forecastState === 'sunny') targetSoc = 40;\n else if (forecastState === 'mixed') targetSoc = 60;\n else targetSoc = 80;\n\n if (soc < targetSoc - 1) {\n mode = 'winter_night_charge_window';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n reason.push(`Hiver HC nuit, cible SOC ${targetSoc}% selon forecast ${forecastState}`);\n } else {\n mode = 'winter_night_idle';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n reason.push(`Hiver HC nuit, SOC ${soc}% déjà suffisant`);\n }\n }\n\n else if (!isWinter && inNightHC) {\n if (soc < 22) {\n mode = 'summer_night_rescue_window';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n reason.push(\"Été HC nuit, secours SOC < 22%\");\n } else {\n mode = 'summer_night_idle';\n effectiveProfile = 'night_slow';\n targetCurrentA = cfg.profiles.night_slow.current_a;\n targetVoltageV = cfg.profiles.night_slow.voltage_v;\n reason.push(\"Été HC nuit, pas de besoin réseau\");\n }\n }\n\n else if (\n inMiddayHC &&\n soc < 85 &&\n forecastRefKwh < 8 &&\n pvPowerW < 1500\n ) {\n mode = 'midday_catchup_window';\n effectiveProfile = 'midday_grid_catchup';\n targetCurrentA = cfg.profiles.midday_grid_catchup.current_a;\n targetVoltageV = cfg.profiles.midday_grid_catchup.voltage_v;\n reason.push(`HC midi rattrapage : SOC ${soc}% | forecast ${forecastRefKwh} kWh | PV ${pvPowerW} W`);\n }\n\n else if (inDayWindow) {\n if (soc < 80) {\n mode = 'day_pv_boost';\n effectiveProfile = 'pv_boost';\n targetCurrentA = cfg.profiles.pv_boost.current_a;\n targetVoltageV = cfg.profiles.pv_boost.voltage_v;\n reason.push(`Jour SOC bas ${soc}% : capture PV max`);\n } else if (soc < 90) {\n mode = 'day_pv_mid';\n effectiveProfile = 'pv_mid';\n targetCurrentA = cfg.profiles.pv_mid.current_a;\n targetVoltageV = cfg.profiles.pv_mid.voltage_v;\n reason.push(`Jour SOC intermédiaire ${soc}%`);\n } else if (soc < 95) {\n mode = 'day_pv_topoff';\n effectiveProfile = 'pv_topoff';\n targetCurrentA = cfg.profiles.pv_topoff.current_a;\n targetVoltageV = cfg.profiles.pv_topoff.voltage_v;\n reason.push(`Jour top-off vers 95% | SOC ${soc}%`);\n } else {\n mode = 'day_pv_hold';\n effectiveProfile = 'pv_hold';\n targetCurrentA = cfg.profiles.pv_hold.current_a;\n targetVoltageV = cfg.profiles.pv_hold.voltage_v;\n reason.push(`Jour maintien haut SOC ${soc}%`);\n }\n\n if (\n Number.isFinite(batteryVoltageV) &&\n soc < 95 &&\n pvPowerW > 2000 &&\n batteryVoltageV >= (targetVoltageV - 0.15)\n ) {\n targetVoltageV = Math.max(targetVoltageV, 51.3);\n targetCurrentA = Math.max(targetCurrentA, 80);\n if (soc >= 90) {\n effectiveProfile = 'pv_topoff';\n mode = 'day_pv_topoff';\n } else {\n effectiveProfile = 'pv_boost';\n }\n reason.push(`Batterie proche consigne (${round1(batteryVoltageV)}V), relèvement anti-bridage`);\n }\n\n if (\n Number.isFinite(batteryCurrentA) &&\n soc < 95 &&\n pvPowerW > 6000 &&\n batteryCurrentA >= (targetCurrentA - 3)\n ) {\n targetCurrentA = Math.max(targetCurrentA, soc >= 90 ? 80 : 130);\n reason.push(`Courant batterie proche limite (${round1(batteryCurrentA)}A), relèvement du plafond`);\n }\n }\n\n\n else {\n mode = 'off_window_idle';\n effectiveProfile = 'pv_hold';\n targetCurrentA = cfg.profiles.pv_hold.current_a;\n targetVoltageV = cfg.profiles.pv_hold.voltage_v;\n reason.push(\"Hors fenêtre utile\");\n }\n}\n\nif (overrideActive) {\n const ov = profileValues(overrideProfile);\n if (ov) {\n targetCurrentA = ov.current_a;\n targetVoltageV = ov.voltage_v;\n effectiveProfile = `override_${overrideProfile}`;\n mode = `${mode}_override`;\n reason.unshift(\n `Override actif jusqu'à ${overrideUntil} | profil=${overrideProfile}` +\n (overrideReason ? ` | ${overrideReason}` : '')\n );\n }\n} else if (overrideEnabled && overrideProfile !== 'auto') {\n reason.push(\"Override configuré mais inactif ou expiré\");\n}\n\ntargetCurrentA = round1(targetCurrentA);\ntargetVoltageV = round1(targetVoltageV);\n\nconst shouldPublishCurrent =\n !Number.isFinite(currentMaxChargeCurrentA) ||\n Math.abs(targetCurrentA - currentMaxChargeCurrentA) >= cfg.currentPublishDelta;\n\nconst shouldPublishVoltage =\n !Number.isFinite(currentMaxChargeVoltageV) ||\n Math.abs(targetVoltageV - currentMaxChargeVoltageV) >= cfg.voltagePublishDelta;\n\nconst shortReason = reason.join(' | ').slice(0, 255);\n\nconst signature = [\n now.date,\n mode,\n effectiveProfile,\n `i=${targetCurrentA}`,\n `v=${targetVoltageV}`\n].join('|');\n\nconst signatureChanged = signature !== lastSignature;\n\nconst result = {\n timestamp_paris: now.localStamp,\n\n inputs: {\n soc_percent: soc,\n battery_voltage_v: Number.isFinite(batteryVoltageV) ? batteryVoltageV : null,\n battery_current_a: Number.isFinite(batteryCurrentA) ? batteryCurrentA : null,\n pv_power_w: pvPowerW,\n edf_switch_observed: edfSwitch,\n today_remaining_kwh: todayRemainingKwh,\n tomorrow_kwh: tomorrowKwh,\n current_max_charge_current_a: currentMaxChargeCurrentA,\n current_max_charge_voltage_v: currentMaxChargeVoltageV,\n auto_enabled: autoEnabled,\n notifications_enabled: notificationsEnabled,\n last_signature: lastSignature || null,\n\n override_enabled: overrideEnabled,\n override_profile: overrideProfile,\n override_current_a: Number.isFinite(overrideCurrentA) ? overrideCurrentA : null,\n override_voltage_v: Number.isFinite(overrideVoltageV) ? overrideVoltageV : null,\n override_until: overrideUntil || null,\n override_reason: overrideReason || null\n },\n\n computed: {\n is_winter: isWinter,\n in_night_hc: inNightHC,\n in_midday_hc: inMiddayHC,\n in_day_window: inDayWindow,\n forecast_reference_kwh: round1(forecastRefKwh),\n forecast_state: forecastState,\n override_active: overrideActive\n },\n\n decision: {\n mode,\n effective_profile: effectiveProfile,\n target_current_a: targetCurrentA,\n target_voltage_v: targetVoltageV,\n should_publish_current: shouldPublishCurrent,\n should_publish_voltage: shouldPublishVoltage,\n critical_alert: criticalAlert,\n signature,\n signature_changed: signatureChanged,\n reason,\n short_reason: shortReason\n },\n\n ha_service_calls: {\n helper_current: {\n domain: 'input_number',\n service: 'set_value',\n data: {\n entity_id: 'input_number.victron_target_charge_current',\n value: targetCurrentA\n }\n },\n\n helper_voltage: {\n domain: 'input_number',\n service: 'set_value',\n data: {\n entity_id: 'input_number.victron_target_charge_voltage',\n value: targetVoltageV\n }\n },\n\n helper_soc_live: {\n domain: 'input_number',\n service: 'set_value',\n data: {\n entity_id: 'input_number.victron_soc_live',\n value: soc\n }\n },\n\n helper_mode: {\n domain: 'input_text',\n service: 'set_value',\n data: {\n entity_id: 'input_text.victron_charge_mode',\n value: mode\n }\n },\n\n helper_reason: {\n domain: 'input_text',\n service: 'set_value',\n data: {\n entity_id: 'input_text.victron_charge_reason',\n value: shortReason || 'Aucune raison'\n }\n },\n\n helper_profile: {\n domain: 'input_text',\n service: 'set_value',\n data: {\n entity_id: 'input_text.victron_effective_charge_profile',\n value: effectiveProfile\n }\n },\n\n helper_signature: {\n domain: 'input_text',\n service: 'set_value',\n data: {\n entity_id: 'input_text.victron_charge_last_signature',\n value: signature\n }\n },\n\n mqtt_current: {\n domain: 'mqtt',\n service: 'publish',\n data: {\n topic: MQTT_TOPIC_CHARGE_CURRENT,\n payload: JSON.stringify({ value: targetCurrentA }),\n retain: false\n }\n },\n\n mqtt_voltage: {\n domain: 'mqtt',\n service: 'publish',\n data: {\n topic: MQTT_TOPIC_CHARGE_VOLTAGE,\n payload: JSON.stringify({ value: targetVoltageV }),\n retain: false\n }\n },\n\n logbook: {\n domain: 'logbook',\n service: 'log',\n data: {\n name: 'Victron Auto Charge',\n message: `${mode} | profile=${effectiveProfile} | I=${targetCurrentA}A | V=${targetVoltageV}V | SOC=${soc}% | ${shortReason}`,\n entity_id: 'sensor.victron_battery_soc'\n }\n },\n\n mobile_notification: {\n domain: cfg.mobileNotifyDomain,\n service: cfg.mobileNotifyService,\n data: {\n title: 'Victron Auto Charge',\n message: `${mode} | profile=${effectiveProfile} | I=${targetCurrentA}A | V=${targetVoltageV}V | SOC=${soc}%`,\n data: {\n push: {\n \"interruption-level\": \"time-sensitive\",\n sound: { name: \"default\" }\n },\n ttl: 0,\n priority: \"high\"\n }\n }\n }\n }\n};\n\nreturn [{ json: result }];\n"
|
|
},
|
|
"id": "a98c5bda-cf34-447e-942e-37ae75a45d5c",
|
|
"name": "Compute Charge Targets",
|
|
"type": "n8n-nodes-base.code",
|
|
"typeVersion": 2,
|
|
"position": [
|
|
512,
|
|
0
|
|
]
|
|
},
|
|
{
|
|
"parameters": {
|
|
"jsCode": "const root = $input.first().json;\nconst actions = [];\n\n// Helpers : toujours mis à jour\nactions.push({\n json: {\n action: 'helper_mode',\n ...root.ha_service_calls.helper_mode\n }\n});\n\nactions.push({\n json: {\n action: 'helper_reason',\n ...root.ha_service_calls.helper_reason\n }\n});\n\nactions.push({\n json: {\n action: 'helper_current',\n ...root.ha_service_calls.helper_current\n }\n});\n\nactions.push({\n json: {\n action: 'helper_voltage',\n ...root.ha_service_calls.helper_voltage\n }\n});\n\nactions.push({\n json: {\n action: 'helper_soc_live',\n ...root.ha_service_calls.helper_soc_live\n }\n});\n\nif (root.ha_service_calls.helper_profile) {\n actions.push({\n json: {\n action: 'helper_profile',\n ...root.ha_service_calls.helper_profile\n }\n });\n}\n\n// Signature + log seulement si changement réel\nif (root.decision.signature_changed) {\n actions.push({\n json: {\n action: 'helper_signature',\n ...root.ha_service_calls.helper_signature\n }\n });\n\n actions.push({\n json: {\n action: 'logbook',\n ...root.ha_service_calls.logbook\n }\n });\n}\n\n// D'abord les limites Victron\nif (root.decision.should_publish_current) {\n actions.push({\n json: {\n action: 'mqtt_current',\n ...root.ha_service_calls.mqtt_current\n }\n });\n}\n\nif (root.decision.should_publish_voltage) {\n actions.push({\n json: {\n action: 'mqtt_voltage',\n ...root.ha_service_calls.mqtt_voltage\n }\n });\n}\n\n// Notification iPhone seulement si critique + activée\nif (root.inputs.notifications_enabled && root.decision.critical_alert) {\n actions.push({\n json: {\n action: 'mobile_notification',\n ...root.ha_service_calls.mobile_notification\n }\n });\n}\n\nreturn actions;\n"
|
|
},
|
|
"id": "d0a3ecb8-6c4d-46e6-a81c-cb84a789b0d7",
|
|
"name": "Build HA Service Actions",
|
|
"type": "n8n-nodes-base.code",
|
|
"typeVersion": 2,
|
|
"position": [
|
|
768,
|
|
0
|
|
]
|
|
},
|
|
{
|
|
"parameters": {
|
|
"method": "POST",
|
|
"url": "={{ 'http://10.10.10.17:8123/api/services/' + $json.domain + '/' + $json.service }}\n",
|
|
"authentication": "genericCredentialType",
|
|
"genericAuthType": "httpBearerAuth",
|
|
"sendHeaders": true,
|
|
"headerParameters": {
|
|
"parameters": [
|
|
{
|
|
"name": "Content-Type",
|
|
"value": "application/json"
|
|
},
|
|
{
|
|
"name": "accept",
|
|
"value": "application/json"
|
|
}
|
|
]
|
|
},
|
|
"sendBody": true,
|
|
"specifyBody": "json",
|
|
"jsonBody": "={{ $json.data }}",
|
|
"options": {}
|
|
},
|
|
"id": "88eb5cba-7ecb-4fca-a995-fd8612118f3a",
|
|
"name": "Execute HA Service",
|
|
"type": "n8n-nodes-base.httpRequest",
|
|
"typeVersion": 4.2,
|
|
"position": [
|
|
1040,
|
|
0
|
|
],
|
|
"alwaysOutputData": true,
|
|
"credentials": {
|
|
"httpBearerAuth": {
|
|
"id": "uv3sknYYigxBkaVN",
|
|
"name": "Bearer Auth account 2"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"connections": {
|
|
"Schedule Trigger": {
|
|
"main": [
|
|
[
|
|
{
|
|
"node": "HA Snapshot via Template",
|
|
"type": "main",
|
|
"index": 0
|
|
}
|
|
]
|
|
]
|
|
},
|
|
"HA Snapshot via Template": {
|
|
"main": [
|
|
[
|
|
{
|
|
"node": "Compute Charge Targets",
|
|
"type": "main",
|
|
"index": 0
|
|
}
|
|
]
|
|
]
|
|
},
|
|
"Compute Charge Targets": {
|
|
"main": [
|
|
[
|
|
{
|
|
"node": "Build HA Service Actions",
|
|
"type": "main",
|
|
"index": 0
|
|
}
|
|
]
|
|
]
|
|
},
|
|
"Build HA Service Actions": {
|
|
"main": [
|
|
[
|
|
{
|
|
"node": "Execute HA Service",
|
|
"type": "main",
|
|
"index": 0
|
|
}
|
|
]
|
|
]
|
|
}
|
|
},
|
|
"nodeGroups": [],
|
|
"authors": "thierry tallagrand",
|
|
"name": null,
|
|
"description": null,
|
|
"autosaved": false,
|
|
"workflowPublishHistory": [
|
|
{
|
|
"createdAt": "2026-07-09T16:18:50.209Z",
|
|
"id": 180,
|
|
"workflowId": "cTeeHy4ePiVeELLh",
|
|
"versionId": "de4ce3dd-bda2-4d27-ba39-72cfc4cfbcbb",
|
|
"event": "activated",
|
|
"userId": "8b9e9552-cd74-4863-82a3-174b3b3befa2"
|
|
},
|
|
{
|
|
"createdAt": "2026-07-09T21:45:53.307Z",
|
|
"id": 190,
|
|
"workflowId": "cTeeHy4ePiVeELLh",
|
|
"versionId": "de4ce3dd-bda2-4d27-ba39-72cfc4cfbcbb",
|
|
"event": "activated",
|
|
"userId": "8b9e9552-cd74-4863-82a3-174b3b3befa2"
|
|
},
|
|
{
|
|
"createdAt": "2026-07-09T16:18:50.185Z",
|
|
"id": 179,
|
|
"workflowId": "cTeeHy4ePiVeELLh",
|
|
"versionId": "de4ce3dd-bda2-4d27-ba39-72cfc4cfbcbb",
|
|
"event": "deactivated",
|
|
"userId": "8b9e9552-cd74-4863-82a3-174b3b3befa2"
|
|
},
|
|
{
|
|
"createdAt": "2026-07-09T21:45:53.283Z",
|
|
"id": 189,
|
|
"workflowId": "cTeeHy4ePiVeELLh",
|
|
"versionId": "de4ce3dd-bda2-4d27-ba39-72cfc4cfbcbb",
|
|
"event": "deactivated",
|
|