Un distributeur qui transmet au constructeur ne doit dependre d'aucun lien exterieur, et le destinataire final lit peut-etre le chinois plutot que le francais. Les trois versions HTML rejoignent donc l'envoi, et le courrier decrit sa piece jointe au lieu de proposer de la fournir. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01KKzkkVTG6KXnGXFFC7X9XJ
80 lines
3.8 KiB
Markdown
80 lines
3.8 KiB
Markdown
# Relevés BMS Pylontech — installation Victron ESS
|
||
*Généré le 05/09/2026*
|
||
|
||
## Français
|
||
|
||
Huit modules US2000C en deux packs de quatre reliés par un LV-HUB. Toutes les
|
||
valeurs ci-dessous sortent des BMS eux-mêmes, lues sur leur console série
|
||
(`info`, `stat`, `soh`, `data … history`, `data … event`).
|
||
|
||
| Code-barres | Pack | Adr. | Cellules déviantes | Écart médian | Événements |
|
||
|---|---|---:|---|---:|---:|
|
||
| K220803C30160322 | 2022 | 1 | 6, 7, 12, 14 | 108 mV | 850 |
|
||
| K220803C30160323 | 2022 | 2 | — | 6 mV | 0 |
|
||
| K220803C30160319 | 2022 | 3 | 2, 6, 10, 12, 15 | 45 mV | 688 |
|
||
| K220803C30160324 | 2022 | 4 | 15 | 57 mV | 900 |
|
||
| Y230202C30371426 | 2023 | 1 | — | 2 mV | 19 |
|
||
| Y230202C30371425 | 2023 | 2 | — | 2 mV | 12 |
|
||
| Y230202C30371431 | 2023 | 3 | — | 2 mV | 6 |
|
||
| Y230202C30371427 | 2023 | 4 | — | 2 mV | 1 |
|
||
|
||
**Où regarder en premier** : `2022-K220803C30160324`, fichier
|
||
`*-evenements-distant-*.csv`, ligne du 23/07/2026 17:20 — la cellule 15 est à
|
||
2963 mV **à 84 % de charge** sous 6,5 A, quand ses quatorze voisines sont à
|
||
3291-3303 mV.
|
||
|
||
**Ce qui écarte une cause d'installation** : le module K220803C30160323 partage
|
||
la chaîne, les courants et les journées de deux modules atteints, et n'a
|
||
enregistré **aucun** événement en seize mois.
|
||
|
||
⚠️ **Horodatages** : les horloges internes des BMS avançaient de 6 h 09 à 6 h 13
|
||
au moment des relevés. **Tous les fichiers CSV de ce dossier sont déjà corrigés
|
||
à l'heure réelle (Europe/Paris)**. Les exports BatteryView `*.txt`, eux, portent
|
||
l'heure brute du module.
|
||
|
||
## English
|
||
|
||
Eight US2000C modules in two packs of four joined by an LV-HUB. Every value
|
||
below comes from the BMS units themselves, read over their serial console.
|
||
|
||
**Where to look first**: `2022-K220803C30160324`, file
|
||
`*-evenements-distant-*.csv`, row of 2026-07-23 17:20 — cell 15 sits at
|
||
2963 mV **at 84 % state of charge** under only 6.5 A, while its fourteen
|
||
neighbours are at 3291-3303 mV.
|
||
|
||
**What rules out an installation cause**: module K220803C30160323 shares the
|
||
chain, the currents and the days of two affected modules, and has recorded
|
||
**zero** events in sixteen months.
|
||
|
||
⚠️ **Timestamps**: the BMS internal clocks ran 6 h 09 to 6 h 13 fast. **All CSV
|
||
files here are already corrected to real local time (Europe/Paris).** The
|
||
BatteryView `*.txt` exports carry the raw module clock.
|
||
|
||
## 中文
|
||
|
||
八个 US2000C 模块,分为两组,每组四个,通过 LV-HUB 连接。以下所有数值均直接
|
||
读取自各模块 BMS 的串口控制台。
|
||
|
||
**建议优先查看**:`2022-K220803C30160324` 目录下的
|
||
`*-evenements-distant-*.csv`,2026-07-23 17:20 这一行 —— 在 **84 % 荷电状态**
|
||
下、仅 6.5 A 放电电流时,15 号电芯降至 2963 mV,而其余十四颗仍在
|
||
3291-3303 mV。
|
||
|
||
**可排除安装或使用原因的依据**:模块 K220803C30160323 与两个受损模块位于同一
|
||
通信链,经历相同电流与相同工况,十六个月内**没有任何**事件记录。
|
||
|
||
⚠️ **时间戳**:采集时各 BMS 内部时钟快 6 小时 09 分至 6 小时 13 分。**本目录中
|
||
所有 CSV 文件均已校正为真实当地时间(欧洲/巴黎)**;BatteryView 导出的
|
||
`*.txt` 文件仍为模块原始时钟。
|
||
|
||
## Fichiers / Files / 文件
|
||
|
||
- `*-histo-distant-*.csv` — historique, un point toutes les 30 min, 15 tensions de cellule
|
||
- `*-evenements-distant-*.csv` — journal d'événements, à la seconde, déclenchements uniquement
|
||
- `*-console.txt` — sorties `info`, `stat`, `soh`, `pwr` verbatim
|
||
- `*_history_*.txt`, `*_event_*.txt` — exports BatteryView d'origine (UTF-16)
|
||
- `rapport/` — le rapport d'analyse en français, anglais et chinois (HTML,
|
||
s'ouvre dans n'importe quel navigateur, sans connexion)
|
||
- `commun/` — sessions console couvrant plusieurs modules a la fois, relevés
|
||
simultanés des trois modules du pack 2022, et captures d'écran BatteryView
|