EVCS Workflow Analysis
|
|
|
|
## Workflow Mechanism Analysis
|
|
|
|
### Energy Context Monitoring
|
|
- Tracks battery SOC, PV power, house load, grid power, and EVCS current
|
|
- Monitors vehicle connection status
|
|
- Continuously evaluates energy balance
|
|
|
|
### Decision Logic
|
|
- Primary decision: "stop_not_connected" when vehicle is not connected
|
|
- Secondary decisions based on energy context (night_hc, day_hc)
|
|
- Source authorization: "Bloqué" (Blocked) when conditions aren't met
|
|
|
|
### Control Flow
|
|
- Surplus controller active but only manages surplus when vehicle is connected
|
|
- Grid power used when solar is unavailable and house needs must be met
|
|
- Manual mode allows override of automated decisions
|
|
|
|
### State Transitions
|
|
- Vehicle connection status triggers different control paths
|
|
- Energy context changes trigger different strategies
|
|
- User interventions (manual mode) can override automated decisions
|
|
|
|
## Situational Framework
|
|
|
|
| Situation | Vehicle Status | Solar Power | House Load | Grid Power | EVCS Current | Decision Logic |
|
|
Control Action |
|
|
|---------|----------------|------------|-----------|------------|--------------|----------------|------------
|
|
----|
|
|
| No Vehicle, No Solar | Disconnected | 0 W | 696 W | ON | 0 A | stop_not_connected | Grid powers house |
|
|
| No Vehicle, Solar | Disconnected | 683 W | 696 W | OFF | 0 A | stop_not_connected | Solar powers house |
|
|
| Vehicle Connected, No Solar | Connected | 0 W | 696 W | ON | 0 A | auto_solar_plus | Grid powers house,
|
|
EVCS idle |
|
|
| Vehicle Connected, Solar | Connected | 683 W | 696 W | OFF | 0 A | auto_solar_plus | Solar powers house,
|
|
EVCS idle |
|
|
| Vehicle Connected, High Demand | Connected | 0 W | 1000 W | ON | 7 A | auto_solar_plus | Grid powers house,
|
|
EVCS charges |
|
|
| Manual Override | Any | Any | Any | Any | Any | Stop | Manual control |
|
|
|
|
## Key Insights
|
|
1. The system prioritizes grid power for house needs when solar is unavailable
|
|
2. The "stop_not_connected" logic prevents EV charging but doesn't manage grid power
|
|
3. The surplus controller only activates when vehicle is connected and there's surplus energy
|
|
4. Manual mode allows complete override of automated decisions
|
|
|
|
## Recommendations
|
|
1. Create a rule to disable grid power when no vehicle is connected and solar is unavailable
|
|
2. Implement a "low energy" mode that prioritizes battery charging over grid power
|
|
3. Add a "maintenance" mode that allows manual control of all systems
|
|
4. Create a monitoring dashboard to track energy flows in real-time
|
|
|